Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 155 (1996), S. 346-346 
    ISSN: 1432-1076
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 157 (1998), S. 346-348 
    ISSN: 1432-1076
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Acta crystallographica 16 (1963), S. 446-451 
    ISSN: 0001-5520
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background During the baseline period of a clinical trial comparing different dosage schedules of inhaled steroids, asthmatic children (aged 6–10 years) were expected to meet the inclusion criterion of airways hyper-responsiveness (PD20 methacholine 〈 80 µg) after withdrawal of inhaled corticosteroids for 2–8 weeks. However, many children failed to do so.Objective It has been shown that young wheezing children may outgrow their symptoms. We investigated if differences between children with and without airways hyper-responsiveness after withdrawal of inhaled corticosteroids were compatible with differences between transient and persistent wheezers found in other studies.Methods Seventy-eight children entered the study, of which 41 developed airways hyper- responsiveness after withdrawal of inhaled corticosteroids, and 37 did not. These two groups of children were compared with respect to differences in demographic, clinical, and immunological features (IL-4, IL-5, IL-10, and IFN-γ produced by Con A stimulated peripheral mononuclear cells (PBMCs) and serum IL-4, IL-5 and soluble intercellular adhesion molecule-1 (sICAM-1)).Results Hyper-responsive children had more atopic features (positive RAST, high IgE, eczema), lower levels of FEV1 and lower concentrations of sICAM-1 than non-hyper-responsive children. Apart from a borderline significantly higher IL-4 production in the hyper-responsive group, other immunologic parameters were comparable. Multivariate logistic regression analysis showed that high serum IgE, low FEV1, and low sICAM-1 levels were independently associated with the presence of airways hyper-responsiveness after stopping inhaled corticosteroids. Atopy was associated with higher concentrations of IL-4 in the hyper-responsive group.Conclusion After withdrawal of inhaled corticosteroids many children previously diagnosed with asthma did not develop airways hyper-responsiveness. We conclude that hyper-responsive children share features with persistent wheezers as found in previous studies, whereas the non-hyper- responsive children may represent transient wheezers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background Asthma is characterized by eosinophilic airways inflammation with elevated levels of IL-4, IL-5 and sICAM-1, and reduced levels of IL-10 and IFN-γ. Inhaled corticosteroids powerfully reduce airways inflammation.Objective To investigate if eosinophil counts, serum eosinophilic cationic protein (ECP) and sICAM-1 levels, as well as serum and production of cytokines (IL-4, IL-5, IL-10, IFN-γ) by peripheral blood monocytes (PBMCs) are useful markers to monitor therapy with inhaled fluticasone propionate (FP) in asthmatic children.Methods In a double-blind, 1-year study, 55 asthmatic children (aged 6–10 years) stopped inhaled corticosteroids for a mean period of 24 days and were randomized to receive either FP 200 µg/day (constant dose group), or a starting dose of FP 1000 µg/day with two monthly reductions to 500, 200 and 100 µg/day (stepdown group). Hyper-responsiveness, symptom scores and blood sampling were performed at 2-month intervals.Results Symptoms and hyper-responsiveness improved significantly in both treatment groups after reintroduction of FP. Eosinophil counts decreased significantly more during the first 2 months of FP in the stepdown group than in the constant dose group (P = 0.03). We found a trend towards a dose-dependent response in changes of eosinophil counts and serum ECP levels during treatment. Serum IL-4 and IL-5 levels were undetectable in the majority of children. No significant effect of the dose of FP on the release of IL-4, IL-5, IL-10 or IFN-γ by Con A stimulated PBMCs was found. sICAM-1 levels did not significantly differ at any time point between the two groups.Conclusion Serum ECP as well as peripheral blood eosinophils, cytokine production by PBMCs and sICAM-1 levels are insensitive markers in titrating and monitoring therapy with inhaled corticosteroids over a wide dose range in childhood asthma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1398-9995
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: In studies on atopic dermatitis (AD), different scoring systems are used to evaluate the severity of the disease. The objective of this study was to investigate agreement between observers in the assessment of the overall severity of AD, and interobserver variation in the assessment of severity of AD for each scoring item separately, using the Simple Scoring System (SSS), the Scoring Atopic Dermatitis (SCORAD) index, and the Basic Clinical Scoring System (BCSS), and, furthermore, to investigate agreement between these three scoring systems in the assessment of the overall severity of AD. Eighty-two patients (42 male) with AD, mean age 13.4 years (range 0.2−67.0), were included. Agreement between observers in assessing the overall AD severity scores, and interobserver variation in assessing AD severity of each scoring item separately were determined in 34 of these 82 patients by two physicians scoring the severity of AD by the three scoring systems. To determine agreement between the scoring systems, one physician scored the severity of AD in all patients with the three scoring systems. Agreement between observers and agreement between the three scoring systems was calculated by Cohen's kappa (κ) and by the measure of agreement according to Bland & Altaian. κ〉0.4 represents fair agreement; κ〉0.75 excellent agreement. In addition, interobserver variation for each scoring item separately was calculated by the Wilcoxon signed rank test. The mean differences (d) and the limits of agreement (d±2 SD of the differences) between observers by the SSS and the SCORAD were −0.82±5.58 and −0.28±7.49, respectively. κ between observers for the BCSS was 0.90 (95% CI 0.79−1.03). By the SSS, significant interobserver variation was found in assessing the severity of excoriations (P=0.02) and scales (P=0.02). By the SCORAD, significant interobserver variation was found in assessing the severity of edema/papulation (P=0.04), erythema (P=0.04), and excoriations (P=0.01). No significant interobserver variation was found in assessing the extent of AD. The mean difference and the limits of agreement between the SSS and the SCORAD were −4.17±9.52. k between the SSS and the BCSS was 0.21 (95% CI 0.09−0.33), and k between the SCORAD and the BCSS was 0.38 (95% CI 0.26−0.51). We found good agreement between observers assessing the overall severity of AD in the lower and higher scoring rates by the SSS and the SCORAD, and excellent agreement by the BCSS. Significant interobserver variation was found on the isolated intensity items scales, excoriations, edema/papulation, and erythema. We found poor agreement between the three scoring systems in assessing the overall severity of AD, indicating that the SSS, the SCORAD, and the BCSS cannot be used interchangeably to assess the overall severity of AD.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    facet.materialart.
    Unknown
    Washington : Periodicals Archive Online (PAO)
    International Monetary Fund staff papers. 10:3 (1963:Nov.) 397 
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Copenhagen : International Union of Crystallography (IUCr)
    Applied crystallography online 27 (1994), S. 164-176 
    ISSN: 1600-5767
    Source: Crystallography Journals Online : IUCR Backfile Archive 1948-2001
    Topics: Geosciences , Physics
    Notes: Adequate alignment of instrumentation and specimens is imperative for the successful performance of residual-stress measurements by means of neutron diffraction. This paper presents a number of alignment methods that enable the user to align reproducibly a stress-measurement setup and a specimen positioned therein. Most of these methods employ the position and the direction of the incident neutron beam as their primary source of geometric reference. A mathematical description for each of the proposed alignment steps is given, which makes the alignment quantitative and enables quantitative assessment of the alignment quality after each alignment step. Examples from actual practice show that the alignment quality that can be achieved using these methods is better than 0.05 mm for translations and better than 0.05° for rotations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 295 (1982), S. 214-215 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The mechanism that produces the line is thought to be due either to fluorescence of the grains in a UV radiation field10 (but this requires very high efficiencies) or to the heating of very small grains to high temperatures (several hundred degrees)11. The presence of the feature in extragalactic ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [s.l.] : Nature Publishing Group
    Nature 292 (1981), S. 814-816 
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Rieke et al.1'2 recently detected several objects at 2.2 jxm in optically blank fields of flat spectrum radio sources3 4, and derived such large IR/optical spectral indices (a = -d In flux density/d In frequency) aKB 3 that they proposed a new class of quasar, because other properties of the ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...