Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In the reversed field experiment the electron temperature and density at the edge are measured from the intensity ratio of selected lines emitted by an atomic helium beam injected into the plasma. Helium is injected through a single microtube 30 mm long and with 150 μm of internal diameter. Four beam splitters allow three interference filters, coupled to linear array cameras or alternatively to photomultipliers, and a charge coupled device camera to observe the same beam volume. The application of photomultipliers as detectors has recently increased the time resolution of the diagnostic. This allows following the time evolution of edge density and temperature during nonstationary processes. Moreover, the enhanced time resolution increases the capability of the diagnostic to measure the edge electron temperature and density fluctuations, which are relevant to the edge electrostatic transport studies. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: In RFX a monitor for the measurement of the on-axis electron temperature with high temporal resolution has been designed and operated during the last experimental campaigns. It consists of four soft x-ray (SXR) diodes which observe the plasma through four beryllium filters of different thickness. In this article the main design issues are presented. The measured values of the temperature, computed both with the standard double foil method and with a fit of all the available signals, are reported, correlated with the main plasma parameters and briefly compared with the results of other diagnostics. The main causes of systematic error, the effect of the noise and the reliability of the results in various plasma conditions have been investigated. Dynamic evaluations of the temperature up to a maximum bandwidth of 5 kHz are described, confirming the potentialities of the technique to follow fast phenomena. Possible improvements of the diagnostic and future developments are also pointed out. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The ultra-soft x-ray duochromator based on two multilayer mirrors installed on the reversed field pinch experiment (RFX) reversed field pinch is described. Built at the Budker Institute of Nuclear Physics of Novosibirsk, it has been designed to monitor the time behavior of the hydrogen and helium-like resonant transitions of carbon and oxygen, the main impurities in the RFX emission spectrum, with the possibility of scanning the wavelengths between 16 and 45 Å. The wavelengths can be independently selected for both the mirrors (made of Ni/C and Cr/C layers, respectively) via a aitch-theta–2aitch-theta mechanism, without breaking the vacuum. The detector is based on a scintillator layer deposited on the head of a photomultiplier. Vacuum ultraviolet and visible radiation is cut by means of thin metal films (Fe, Al, Cr) deposited on a mylar substrate and on the scintillator. The wavelength resolution (λ/Δλ) of 40 to 50 in the region of interest is provided by a Soller collimator and a precollimator stage placed in front of the mirror. The relatively large etendue allows one to perform observation in a wide range of experimental conditions. Sample results of the chordal observations are compared in absolute units with the predictions of a collisional–radiative one-dimensional impurity transport code. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The vacuum Czerny–Turner high-resolution spectrometer observing the plasma of the reversed-field-pinch device RFX has been absolutely calibrated in the spectral range 1215–7000 A(ring), in order to measure the emission spectrum in absolute units, with particular reference to the heliumlike carbon and oxygen ion lines. The source used to calibrate the spectrometer in the vacuum and near-ultraviolet region is a deuterium lamp; its spectral radiance was determined by comparison with the synchrotron radiation of the electron storage ring BESSY, in Berlin. A typical error of 35% has been estimated. In the visible a standard tungsten lamp has been used. The calibration has been transferred to an ultragrazing incidence XUV spectrometer by means of the branching-ratio technique, using the intensity ratio between the intercombination 1s2 1S–1s2p 3P0 and the 1s2s 3S–1s2p 3P0 transitions of carbon, nitrogen, and oxygen heliumlike ions. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The conceptual feasibility of an active spectroscopic diagnostic on reversed field experiment (RFX) to measure the radial profiles of ion temperature, toroidal and poloidal drift velocities, and main impurity densities is examined. In particular a charge exchange recombination spectroscopy experiment is simulated for carbon and helium impurities. The motional Stark effect on the beam atoms injected into RFX is estimated as a means to measure the magnetic field pitch and intensity. A modulated beam injector (500 Hz) with 2 A of equivalent current and an energy of 50 keV/amu appears to be adequate to perform the measurements over a reasonable range of operational regimes. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 66 (1995), S. 610-612 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The systems installed on the RFX reversed field pinch to study the impurity influxes are described. They comprise of telescope lenses, coupled through optical fibers and interference filters or spectrographs to photomultipliers for time-resolved analysis, and charge coupled device (CCD) cameras. The solutions adopted aim at giving an insight into the impurity production mechanisms in a situation characterized by largely asymmetric plasma–wall interactions. Main gas and various impurity influxes from the same area of the first wall are compared by means of very simple light splitters interposed between telescope lenses and narrow band filters. Four high-resolution CCD cameras also equipped with interference filters cover more than half of the first wall allowing detailed spatial studies of the impurity influx distributions. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 61 (1990), S. 2801-2803 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The x-ray pulse height analysis diagnostic designed and built for the RFX reversed field pinch experiment is presented. The system is designed so as to be sensitive over a wide range of RFX operational conditions (100 eV ≤Te ≤ 2 keV). An array of three liquid N2 cooled Si(Li) detectors looks at the plasma through an equatorial port of the torus and can be tilted ±20° off the plane in order to scan over the central half of the minor diameter on a shot-to-shot basis. A second windowless single detector views the plasma along a fixed chord through a second equatorial port and is sensitive to x-ray energies as low as 500 eV. Commercial electronics are mostly used. The throughput is limited only by the shaping amplifier and pulse pileup rejector. Software simulation of the x-ray flux, including the pulse pileup rejection procedure of the electronic chain, was used to dimension the diagnostic, i.e., number of detectors, size of the apertures, and filter combinations. Preliminary tests indicate 20 ms as a realistic target for the electron temperature time resolution, reducible to 5 ms when all of the four detectors are addressed to the same properly chosen x-ray energy region.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Plant pathology 53 (2004), S. 0 
    ISSN: 1365-3059
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: A 3-year study was carried out in north-east Italy, the site of recent elm yellows epidemics, to identify vectors for the elm yellows phytoplasma. Using PCR analysis, Ulmus minor and Ulmus pumila, each with and without symptoms, were positive for the elm yellows phytoplasma. Macropsis mendax, a univoltine and monophagous leafhopper, was shown to be the vector of the elm yellows-associated disease agent. PCR analyses demonstrated that the insect was infected both in natural conditions and in the screenhouse after acquisition-feeding on infected elm plants. Groups of M. mendax, collected from naturally infected elm trees, transmitted elm yellows phytoplasma to elm test plants. In nature, Alnus glutinosa trees affected by alder yellows were found in the surroundings of yellows-affected elm trees; the associated disease agent of alder yellows was transmitted under controlled conditions from alder to elm test plants by grafting.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: This paper describes the vacuum Czerny–Turner spectrometer with a 1.33 m focal length installed on the RFX fusion experiment. The optics are coated with MgF2 and the image intensifier, protected by a vacuum sealed MgF2 window, features a dual photocathode system, CsTe on one half and S20 on the other; thus the instrument covers efficiently the wide spectral range from the MgF2 limit to the near infrared. Sensitivity at short wavelengths is limited by the reflectance of mirrors and the transmittance of the MgF2 window. The detector is completed by a fast optical multichannel analyzer whose 1024 photodiodes can be read out in a time of 250 μs. The instrument can also be operated in a duochromator mode by deflecting the diffracted beam onto a second detector system, where two photomultipliers are applied to two exit slits, one fixed and the other remotely movable in such a way that the intensity ratios of two lines can be monitored for diagnostic purposes. Some examples of obtained spectra illustrating the instrument performance and comprising first results from the RFX plasma are presented.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Plant pathology 51 (2002), S. 0 
    ISSN: 1365-3059
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Several uncultivated trees of the species Prunus spinosa, P. cerasifera and P. domestica, sampled both adjacent to European stone fruit yellows (ESFY)-infected orchards and in isolation from cultivated stone fruit plants, were found to be infected by ESFY phytoplasma. These species were also colonized by Cacopsylla pruni, vector of the ESFY agent. In contrast, uncultivated species of Prunus avium, P. cerasus and P. mahaleb hosted neither the pathogen nor the vector. Insect- and graft-transmission trials of ESFY phytoplasma conducted under controlled conditions confirmed the data obtained in the field. The role played by the wild Prunus species is discussed and appears to be fundamental in the epidemic cycle of the disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...