Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1468-2982
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The efficacy and safety of long-acting propranolol (LA.P), 160 mg once-daily, in the prophylactic treatment of migraine have been tested against placebo in a multicentric, double-blind, randomized study. The two groups are compared in a parallel manner over a treatment period of 12 weeks, following a 4-week placebo run-in period. Fifty-five of the 74 patients who entered the trial were included at the end of the run-in period. Forty-one patients completed the study. None of the 14 patients who withdrew from the study did so because of side effects. The statistical analysis was done according to the “intention to treat” principle. LA.P was significantly more effective than placebo in reducing the frequency of migraine attacks (p=0.01 by variance analysis). LA.P reduced the average number of monthly crises by 48% on day 84. There was a slight but significant reduction of the systolic blood pressure and heart rate in the erect position, but there was no significant difference between LA.P and placebo regarding either the number of complaints or the number of side effects elicited out of a 17-item questionnaire. None of the observed side effects led to a withdrawal from treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 70 (1997), S. 277-279 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The aim of this work is to study gray tracking during type II second-harmonic-generation 1064→532 nm in halide flux grown KTiOPO4 crystals. The repetition rate of the laser varies from 1 to 20 kHz. We experimentally demonstrate that the gray-tracking threshold, expressed by the harmonic peak power density, is a decreasing exponential function of the Q-switch frequency. The corresponding 532 nm average power density, however, remains constant. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...