    ISSN: 1432-0428
    Keywords: Keywords Perimetry ; Visual Field ; Short-Wavelength Sensitivity ; Selective Loss ; Diabetic Macular Oedema.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The aim of the study was to compare the sensitivity of short-wavelength and conventional automated static threshold perimetry for the psychophysical detection of abnormality in patients with clinically significant diabetic macular oedema. The sample comprised 24 patients with clinically significant diabetic macular oedema (mean age 59.75 years, range 45–75 years). One eye of each patient was selected. Exclusion criteria included the presence of lenticular opacity. The sensitivity of the macular visual field of each patient was determined with programme 10–2 of the Humphrey Field Analyser on two occasions, using both short-wavelength and conventional stimulus parameters; the results of the second session were analysed to minimise learning effects. A pointwise horizontal hemifield asymmetry analysis was derived for short-wavelength perimetry (thereby negating the influence of pre-receptoral absorption); the pointwise pattern deviation probability plot was analysed for conventional perimetry. Abnormality was defined as 3 or more contiguous stimulus locations with negative asymmetries (short-wavelength) or reduced sensitivity values (conventional) that resulted in a statistical probability level of p less than 0.05. The fields of 8 patients were abnormal as assessed by conventional perimetry while all were classified as abnormal using short-wavelength perimetry. In the 8 patients who exhibited both abnormal conventional and abnormal short-wavelength perimetry results, the extent of field loss was generally greater using short-wavelength perimetry. The position of the localised field loss (i. e. as distinct from field loss that was generalised across the visual field) assessed by short-wavelength perimetry corresponded with the clinical mapping of the area of diabetic macular oedema but the extent of this loss was generally greater than that suggested by clinical assessment. Short-wavelength automated perimetry offers improved sensitivity for the psychophysical detection of clinically significant diabetic macular oedema. [Diabetologia (1998) 41: 918–928]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0428
    Keywords: Keywords Automated perimetry ; visual field loss ; laser photocoagulation ; diabetic macular oedema.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The aim of the study was to determine the effect of laser photocoagulation for clinically significant diabetic macular oedema (DMO) on macular visual function as assessed by conventional and short-wavelength automated static threshold perimetry. The sample comprised 24 patients who required laser photocoagulation for clinically significant DMO (mean age 59.75 years, range 45–75 years). One eye of each patient was selected for the study. Patients underwent conventional and short-wavelength perimetry using programme 10-2 of the Humphrey Field Analyser on two separate occasions prior to treatment and subsequently within 1 week of, and at 1, 2, 4 and 12 weeks after, treatment. The pointwise pattern deviation plot was analysed for conventional perimetry and a pointwise horizontal and vertical hemifield asymmetry analysis was derived for short-wavelength perimetry (thereby negating the influence of pre-receptoral absorption). The extent of sensitivity loss was determined by counting the number of stimulus locations with statistical probability levels of p less than 0.05. Group mean log minimum angle of resolution (logMAR) visual acuity was largely unchanged over the course of the study. Conventional perimetry showed an increase in the group mean number of abnormal contiguous stimulus locations from 2.4 (SD 4.3, range 0–14) immediately prior to treatment, to 12.4 (SD 7.8, range 0–30) within 1 week of treatment; at 3 months post-treatment, the group mean number of abnormal contiguous stimulus locations was 8.1 (SD 6.5, range 0–20). A similar but less pronounced change was found for short-wavelength perimetry. The spatial position of the post-treatment localised sensitivity loss corresponded with the area of retinal photocoagulation. Despite proven benefit in the stabilisation of visual acuity, laser photocoagulation for clinically significant DMO invariably results in a localised loss of perimetric sensitivity within 10 ° eccentricity of the fovea. Evidence for the value of laser therapy for clinically significant DMO must be re-examined. [Diabetologia (1998) 41: 1283–1292]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Anthropology 18 (1989), S. 245-266 
    ISSN: 0084-6570
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Ethnic Sciences , Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] The mouse plasmacytoma J558L secretes ? 1 light chains but does not produce an immunoglobulin heavy chain . The strategy used in the production of the recombinant IgE antibody was to introduce a plasmid that encodes a complete immunoglobulin e heavy chain into J558L and thus direct the production ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1476-4687
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Chemistry and Pharmacology , Medicine , Natural Sciences in General , Physics
    Notes: [Auszug] Cosmid clones containing the human γ, ε and α heavy chain constant region genes and an ε pseudogene have been isolated. All these genes have a switch sequence detectable by hybridization. We have studied overlapping cosmids covering two separate regions of the genome, and the ...
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 59 (1985), S. 301-308 
    ISSN: 1573-2622
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Sophistication of computer software and flexibility of stimulus and background luminance parameters in static perimeter design offer the opportunity for increased information in the assessment of the visual field. Relationships between dynamic ranges and resulting sensitivity gradients in a group of 10 normal 21 year old subjects using the Octopus automated perimeter, the Dicon Autoperimeter 2000 and the Friedmann VFA II are assessed. Inadequacies in the use of normative data to assess the visual field are noted. Implications for the use of dynamic range/sensitivity gradient relationships in visual field assessment without reliance on normative data are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 69 (1988), S. 371-383 
    ISSN: 1573-2622
    Keywords: Visual field ; computer assisted perimeter ; stimulus configuration
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The study investigated the effect of three distinct types of stimulus configuration on the format of the normal sensitivity gradient derived by computer assisted perimetry namely: projected stimuli; light emitting diodes (LED) with the same luminance as the perimeter bowl; and ‘black hole’ LED stimuli. The study comprised two separate parts: 22 age matched subjects were examined with the Dicon AP3000 and with the Topcon SBP-1000 along the 15°–195° meridian of the visual field of the right eye; a further 22 subjects matched for age and gender were examined along the same meridian in an identical manner with the Dicon AP2025 and with the Humphrey Field Analyser 620. The various stimulus parameters were chosen in order to provide uniformity as far as possible between the instruments. The Topcon evoked greater relative sensitivity than the Dicon at all eccentricities although the rate of change of sensitivity with increase in peripheral angle varied between the two instruments at different locations. Centrally the Dicon profile followed more closely that of Humphrey stimulus size II and beyond 5° that of stimulus size I. The Topcon profile followed that of the Humphrey stimulus size II both centrally and peripherally in spite of being geometrically closer to the size III stimulus. It is proposed that the variations in the sensitivity gradient are not exclusively related to stimulus size and spatial summation; the accommodative stimulus of the ‘black hole’ LED stimuli, stimulus colour and thresholding strategy may all be contributing factors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 62 (1986), S. 97-105 
    ISSN: 1573-2622
    Keywords: half-field stimulation ; source derivation ; visually evoked potential
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract There has been much recent conjecture over the apparent source location of the visually evoked potential, particularly in considering the lateralization found in half-field pattern reversal stimulation. This paper presents an alternative by directly identifying the sinks or sources present in the scalp current flow as these correspond to the maximal current flow into or out of the cortex (Nunez, 1981). Hjorth (1975) introduced a practical procedure for source derivation which has proved useful in the interpretation of the electroencephalogram (Wallin and Stalberg, 1980). We have applied source derivaton to cortical evoked potentials and present results obtained from right and left half-field stimulation, (Clement, Flanagan and Harding, 1985) and upper and lower field stimulation in normal subjects and patients with visual deficits.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 1573-2622
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Previous methods for the qualitative evaluation of visual field instruments are subject to certain limitations. A system is proposed to overcome these deficiencies. It has been developed from experiences of a clinical study involving 5 different visual field instruments. The method uses 4 levels of analysis and permits separate appraisals of diagnostic potential and detailed inter-instrument comparative evaluation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1573-2622
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A comparative evaluation of the Octopus automated perimeter (Programmes 21 and 31), the Goldmann Bowl perimeter, the Bjerrum Screen and the Friedmann VFAs Mk I and Mk II was carried out on a heterogenous sample of 75 patients. The results for the sample as a whole were analysed statistically in terms of the scoring system developed by Flanagan, Wild, Barnes, Gilmartin, Good and Crews (1984a). Statistically significant differences between the instruments were found at each of the 4 levels of analysis.