  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 11 (1985), S. 33-38 
    ISSN: 1432-1238
    Keywords: Bollards ; Intensive Care Unit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Permanent floor-mounted “bollards” have been installed in three Intensive Care Areas in the Oxford Teaching Hospitals. Each brings services to one bed and, because access around the head is greatly improved in comparison with the conventional arrangement with the head next to the wall, facilitates both emergency and routine care and improves the safety of the working environment for staff and patients. Differences between the bollards installed in the three units are described and the advantages and disadvantages of each discussed. It is concluded that a bollard should be located to the left of the head of the bed and that it should be about 1100 mm high and 500 mm square. At least two oxygen and vacuum outlets, one air outlet, six electric power sockets and connections for monitoring cables should be provided on the bollard with further power sockets on the adjacent wall. A length of equipment rail mounted across the head of the bed supports the suction equipment required for oral and respiratory tract care and storage space is provided on and below the work surface which is mounted on the wall behind the head of the bed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 629-635 
    ISSN: 1741-0444
    Keywords: Arterial oxygen saturation ; Blood levels of oxygen ; Measurement techniques ; Monitoring ; Oxygen ; Pulse oximetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An in vitro system was developed capable of testing the accuracy and reproducibility of pulse oximeter readings. The pulse oximeter probe receives signals through a pulsating blood cuvette. The development of the design of the cuvette is described. Using the final design (or ‘model finger’), a comparison is made between readings from a Datex Satlite pulse oximeter (SpO2) and saturation values obtained by use of a multiwavelength bench oximeter (SaO2). Linear regression analysis of the data gives SpO2=0·88 SaO2+11·2 (r=0·979, p〈0·001).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...