Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 44 (1989), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: This paper describes a new technique for measuring respiratory gas flows and volumes using polyvinylidene fluoride film.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Anaesthesia 39 (1984), S. 0 
    ISSN: 1365-2044
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A closed loop control system for vasoactive drug infusion is described using a dedicated bedside microcomputer and a single volumetric infusion pump. The signal from an indwelling arterial cannula is taken from the bedside monitor through an analogue/digital converter to a microcomputer. After signal validation changes of infusion rate are calculated and communicated to a volumetric infusion pump through an RS 232 interface. The system has been successfully employed in four patients during cardiac surgery prior to cardiopulmonary bypass and in six cardiac surgical patients in the postoperative period. In both groups mean arterial pressure was controlled within 5 mmHg of target value for 75% of infusion time, and within 10 mmHg for 90% of the duration of infusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Medical & biological engineering & computing 30 (1992), S. 629-635 
    ISSN: 1741-0444
    Keywords: Arterial oxygen saturation ; Blood levels of oxygen ; Measurement techniques ; Monitoring ; Oxygen ; Pulse oximetry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Chemistry and Pharmacology , Medicine
    Notes: Abstract An in vitro system was developed capable of testing the accuracy and reproducibility of pulse oximeter readings. The pulse oximeter probe receives signals through a pulsating blood cuvette. The development of the design of the cuvette is described. Using the final design (or ‘model finger’), a comparison is made between readings from a Datex Satlite pulse oximeter (SpO2) and saturation values obtained by use of a multiwavelength bench oximeter (SaO2). Linear regression analysis of the data gives SpO2=0·88 SaO2+11·2 (r=0·979, p〈0·001).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...