  • 1
    ISSN: 1612-1112
    Keywords: Thermospray MS-MS ; Flow injection analysis ; Phenoxyacid herbicides ; Surface waters
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Optimization of signal-to-noise ratios (S/N) by optimizing electron multiplier (EM) voltage and resolution of the first and second mass analyser in a thermospray (TSP), tandem mass spectrometer system is studied. Using flow injection analysis (FIA) of samples containing eight chlorophenoxy carboxylic acid herbicides and bentazone, and a FIA system, the signal and background (noise) intensity i.e. S/N are studied with selected reaction monitoring (SRM) at different EM voltages. An EM voltage of 2500 V improves the S/N ratios 5.5–13 fold compared to the usual 1700 V. Applying additional resolution voltages of +3 to +4 V to the first and second mass analyser decreases resolution in each mass analyser, but there is no overall loss in selectivity, while the S/N ratios further increase 3–4 fold. The selectivity of measurements was studied using 2,4,5-T ((2,4,5-trichlorophenoxy)acetic acid) and triclopyr, which differ only one mass unit in the selection of the parent and daughter ion mass in the applied SRM method. Resolution could be decreased to 36–54% valley definition, while still ensuring the selectivity. With the herbicides studied, screening of surface water samples spiked at the 1 μg l−1 level, corresponding to 25 pg component s−1 into the MS, is easily achieved under optimum conditions without analyte concentration. Some sample clean-up is recommended, however, because ionization efficiencies tend to diminish with some of the raw sample studied.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Bulletin of environmental contamination and toxicology 35 (1985), S. 711-715 
    ISSN: 1432-0800
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 16 (1982), S. 237-241 
    ISSN: 1612-1112
    Keywords: Liquid chromatography ; Electron capture detection ; Improved interface
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An improved interface for the coupling of a liquid chromatograph (LC) and an electron-capture detector (ECD) allows the use of the LC-ECD combination for the determination of various types of chlorinated aromatic compounds. The addition of up to 6% of dioxan to the hexane used as mobile phase can be tolerated without serious deterioration of detector performance. Derivatization of polar compounds such as anilines, phenylurea herbicides, chlorophenols and hydroxylated polychlorobiphenyls with fluorine-and non-fluorine-containing acid anhydrides is a useful tool to extend the application range of LC-ECD. As an example, the analysis of a spiked soil sample is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; On-line preconcentration ; Polar pollutants ; Water (tap and surface)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An isocratic column liquid chromatographic system with UV absorbance detection at 230 nm has been developed for the rapid trace-level determination of a large number of polar pollutants in water. The systems contains two precolumns, in series, which are packed with a styrenedivinylbenzene (PLRP-S) polymer. The second precolumn is also loaded with sodium dodecylsulphate before use. Each precolumn is combined with a PLRP-S analytical column, and aqueous acetonitrile mixtures (pH 3) are used for the separation of neutral as well as acidic and basic pollutants. With 10-ml water samples the detection limits for all analytes, in tap water, are in the low to sub μg/l range. Relevant analytical data are reported and the advantage of using a dodecylsulphate-loaded precolumn over a cation-exchange precolumn is discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...