Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1238
    Keywords: Pressure-controlled inverse ratio ventilation kwEndinspiratory pressure ; Intrinsic PEEP ; Functional residual capacity ; Hemodynamics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objectives Prolongation of inspiratory time is used to reduce lung injury in mechanical ventilation. The aim of this study was to isolate the effects of inspiratory time on airway pressure, gas exchange, and hemodynamics, while ventilatory frequency, tidal volume, and mean airway pressure were kept constant. Design Randomized experimental trial. Setting Experimental laboratory of a University Department of Anesthesiology and Intensive Care. Animals Twelve anesthetised piglets. Interventions After lavage the reference setting was pressure-controlled ventilation with a decelerating flow; I∶E was 1∶1, and PEEP was set to 75% of the inflection point pressure level. The I∶E ratios of 1.5∶1, 2.3∶1, and 4∶1 were applied randomly. Under open lung conditions, mean airway pressure was kept constant by reduction of external PEEP. Measurement and results Gas exchange, airway pressures, hemodynamics, functional residual capacity (SF6 tracer), and intrathoracic fluid volumes (double indicator dilution) were measured. Compared to the I∶E of 1∶1, PaCO2 was 8% lower, with I∶E 2.3∶1 and 4∶1 (p≤0.01) while PaO2 remained unchanged. The decrease in inspiratory airway pressure with increased inspiratory time was due to the response of the pressure-regulated volume-controlled mode to an increased I∶E ratio. Stroke index and right ventricular ejection fraction were depressed at higher I∶E ratios (SI by 18% at 2.3∶1, 20% at 4∶1; RVEF by 10% at 2.3∶1, 13% at 4∶1;p≤0.05). Conclusion Under open lung conditions with an increased I∶E ratio, oxygenation remained unaffected while hemodynamics were impaired.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: Key words Pressure-controlled inverse ratio ventilation ; End-inspiratory pressure ; Intrinsic PEEP ; Functional residual capacity ; Hemodynamics
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract   Objectives: Prolongation of inspiratory time is used to reduce lung injury in mechanical ventilation. The aim of this study was to isolate the effects of inspiratory time on airway pressure, gas exchange, and hemodynamics, while ventilatory frequency, tidal volume, and mean airway pressure were kept constant. Design: Randomized experimental trial. Setting: Experimental laboratory of a University Department of Anesthesiology and Intensive Care. Animals: Twelve anesthetised piglets. Interventions: After lavage the reference setting was pressure-controlled ventilation with a decelerating flow; I:E was 1:1, and PEEP was set to 75% of the inflection point pressure level. The I:E ratios of 1.5:1, 2.3:1, and 4:1 were applied randomly. Under open lung conditions, mean airway pressure was kept constant by reduction of external PEEP. Measurements and results: Gas exchange, airway pressures, hemodynamics, functional residual capacity (SF6 tracer), and intrathoracic fluid volumes (double indicator dilution) were measured. Compared to the I:E of 1:1, PaCO2 was 8% lower, with I:E 2.3:1 and 4:1 (p≤0.01) while PaO2 remained unchanged. The decrease in inspiratory airway pressure with increased inspiratory time was due to the response of the pressure-regulated volume-controlled mode to an increased I:E ratio. Stroke index and right ventricular ejection fraction were depressed at higher I:E ratios (SI by 18% at 2.3:1, 20% at 4:1; RVEF by 10% at 2.3:1, 13% at 4:1; p≤0.05). Conclusion: Under open lung conditions with an increased I:E ratio, oxygenation remained unaffected while hemodynamics were impaired.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...