Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 2020-2022 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: By a new modification of a parallel plate analyzer, second-order focusing is obtained for arbitrary injection angles. This kind of an analyzer with a small injection angle has the advantage of low operating voltages, compared to the Proca and Green analyzers where the injection angle is 30 deg. The newly proposed analyzer will be very useful for precise energy measurements in the MeV range. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Several improvements in the high-voltage heavy-ion-beam probe (HIBP) are discussed. (1) It is clearly found that the precision slide mount of the detector plates 30° parallel to the base electrode is very effective for the determination of the in-plane entrance angle of the beam in the analyzer to estimate the error in the potential measurement. (2) A two-staged optical trap in the HIBP greatly reduced the effect of the UV radiation in the analyzer. (3) A multiple-plate detector up to 13 measurement points clearly showed the direction of the propagation of the turbulence and path-integral effects. © 1995 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 65 (1994), S. 1606-1612 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The effect of field irregularity due to the use of conducting meshes to cover holes of a lower electrode in a parallel-plate electrostatic analyzer, is experimentally and numerically investigated. Displacement of a focal point and degradation of analyzer characteristics are found in the experiment. Dependence of analyzer characteristics on wire spacing is obtained. Primary results are also confirmed by numerical analysis. Criteria for error estimation are theoretically derived and found to be consistent with the experiment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 4446-4449 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A new modification on the parallel plate analyzer for 500 keV heavy ions to eliminate the effect of the intense UV and visible radiation, is successfully implemented. Its design principle and results of numerical optimization are presented. In addition, the analyzer characteristics experimentally obtained in a high temperature plasma device, are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 73 (2000), S. 121-126 
    ISSN: 1432-1246
    Keywords: Key wordsN,N-Dimethylacetamide ; N-Methylformamide ; Dermal absorption ; Biological monitoring ; Biological half-life
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Objectives: We investigated the potential for the dermal absorption of N,N-dimethylacetamide (DMAC: CAS No. 127-19-5) vapor, the biological half-life of N-methylacetamide (NMAC) in urine as the biological exposure item of DMAC, and the adjustment method for urinary concentrations. Methods: Twelve healthy male volunteers (mean age 25.2 years, range 21–43 years) were exposed to DMAC for 4 h on two occasions at intervals of 96 h or above. Each volunteer sat inside a whole-body-type exposure chamber for the dermal exposure experiment or outside the chamber for the inhalation exposure experiment. The temperature and relative humidity in the chamber were controlled at approximately 26 °C and 40% in order to keep the skin (90% naked) of the volunteers dry. DMAC concentrations were 6.1 ± 1.3 ppm for dermal exposure and 6.1 ± 1.3 ppm for inhalation exposure. Urine samples were collected from 0 h through 36 h and at 48 h and 72 h after the exposure. Extrapolations from exposure concentrations for 4 h to 10 ppm for 8 h were performed. Results: Mean dermal absorption was estimated to be 40.4% of the total DMAC uptake. The biological half-lives of urinary NMAC were 9.0 ± 1.4 h and 5.6 ± 1.3 h via skin and lung, respectively. Mean NMAC in urine just after 5 consecutive workdays (8 h/day) at 10 ppm DMAC exposure was assumed to be 33.7 mg/g · Cr (18.6–70.0 mg/g · Cr). Creatinine-adjusted NMAC concentration in urine for each volunteer within 12 h after the exposure was more closely correlated with the total excretion amount of NMAC up to 36 h than with urinary-volume-adjusted or specific-gravity-adjusted NMAC concentration in both the dermal and inhalation exposure experiments. Conclusions: DMAC vapor was significantly absorbed through the skin. Estimated NMAC values indicate that 20 mg/g · Cr NMAC seems to be appropriate as the biological exposure index.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...