    Ground water monitoring & remediation 11 (1991), S. 0 
    ISSN: 1745-6592
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Geosciences
    Notes: At a study site in the midwestern United States, multiple-completion wells demonstrated that a vertical hydraulic gradient was responsible for the contamination pattern exhibited by chlorinated solvent plumes. The typical pattern consisted of little or no contamination in the upper portion of the aquifer with concentrations increasing with depth. When ground water contamination was discovered in an unexpected portion of the site, water level elevations and contaminant distribution data obtained from multiple-completion wells resulted in identification of the source location. The well eventually determined to be located in the source area displayed contaminant levels much higher in the upper zone of the aquifer — the opposite contamination pattern of other on-site wells. Such results indicated that the spill had occurred near this location and that solvent residing along the capillary fringe was continuing to contaminate the aquifer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Ground water monitoring & remediation 16 (1996), S. 0 
    ISSN: 1745-6592
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Geosciences
    Notes: An investigation of elevated concentrations of nickel and chromium in certain ground water samples collected at Williams Air Force Base (AFB) indicated that type 304 stainless steel well materials are the source. Chloride in the ground water has apparently caused crevice corrosion of the stainless steel well screens installed during site characterization. An evaluation of site geochemistry suggested that chromium released from the well screen would precipitate, while nickel would remain dissolved. Thus, low-flow purging and sampling significantly reduces the chromium found in the ground water samples because such sampling minimizes the collection of artificially entrained particulates. In contrast to chromium, nickel concentrations did not decrease during low-flow purging and sampling, indicating that it is dissolved. Nickel and chromium concentrations are both low following high-volume purging when turbidity levels are stabilized below 10 nephelometric turbidity units prior to sampling. In the latter case, chromium concentration is low because particulate collection is minimized, and nickel concentration is low because of increased dilution. Based on these results, it is recommended that elevated levels of nickel and chromium in ground water samples collected from stainless steel monitoring wells be carefully evaluated, because well materials may be the source. In addition, although low-volume purging is increasingly becoming the sampling method of choice, high-volume purging may be a useful means of determining whether the well materials influence nickel and chromium concentrations.