Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1440
    Keywords: Insulin infusion pump ; Implantation ; CSII ; Intravenous, intraperitoneal insulin infusion
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Five type I diabetic patients were followed prospectively during treatment with continuous subcutaneous insulin infusion by externally worn pumps and during the first 12 months after implantation of a remote-controlled insulin infusion device (ID1, Siemens AG). Stabilized insulin (Hoe 21 GH, Hoechst AG) was infused intravenously in two and intraperitoneally in three patients. Total observation time was 47.2 patient-months after implantation. Two devices had to be explanted prematurely, one because of a technical failure after 101 days, one due to a skin necrosis over the implant after 236 days. HbA1, frequency of hypoglycemia, total insulin dose, and basal rate infusion did not change after implantation. There was a reduction in the insulin antibodies 6 months after start of intravenous or intraperitoneal insulin delivery. Fasting plasma free insulin levels could be normalized only by intraperitoneal insulin infusion. Although a technical and a surgical problem was observed, our data show the successful implantation and clinical use of programmable dosing devices and stabilized insulin.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Virchows Archiv 364 (1974), S. 297-301 
    ISSN: 1432-2307
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Within the framework of an Early Postmortem Brain Sampling Program we had the opportunity to make some light and electron microscopic observations on the orbital cortex of two elderly subjects known to have been free of neurologic and psychiatric disease. Filamentous deposits with the ultrastructural appearance of corpora amylacea were seen inside astrocytic and, more rarely, inside neuronal processes. The findings and their interpretation are discussed in the light of current views on cerebral corpora amylacea and Lafora bodies. It is concluded that today's views on this matter do not account satisfactorily for the present observation or for observations we have quoted from the literature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European archives of psychiatry and clinical neuroscience 219 (1974), S. 105-115 
    ISSN: 1433-8491
    Keywords: Clinical Neuropathology ; Postmortem Tissue Preservation ; Electron Microscopy of Human Brain Tissue ; Klinische Neuropathologie ; Postmortale Gewebserhaltung ; Elektronenmikroskopische Untersuchung menschlichen Hirngewebes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Mit der transorbitalen Nadelautopsie wird eine Technik beschrieben, welche die Entnahme von menschlichem Hirngewebe etwa innerhalb einer Viertelstunde post mortem ermöglicht. Die Stanzzylinder aus dem Orbitalbereich des Frontallappens weisen auf der submikroskopischen Ebene gewöhnlich eine befriedigende bis ausgezeichnete Strukturerhaltung auf. Die Brauchbarkeit der Methode wird auch durch Beispiele interessanter akzidenteller Beobachtungen bei fünf Fällen erläutert, die klinisch weder neurologische noch psychiatrische Störungen gezeigt hatten. Mit Hilfe der frühzeitigen transorbitalen Nadelautopsie lassen sich vor allem elektronenmikroskopische Untersuchungen bei bisher ungeklärten zentralnervösen Krankheitsprozessen durchführen. Außerdem bietet diese Entnahmetechnik auch die Möglichkeit, umfassendere Kenntnisse über die Normvarianten der feineren Strukturverhältnisse im Gehirn von Menschen verschiedener Altersstufen zu gewinnen.
    Notes: Summary We describe a method of transorbital needle autopsy for sampling cerebral tissue about 15 min after death. The specimens of orbital gray and white matter examined under the electron microscope exhibited a tissue preservation ranging from satisfactory to excellent. The validity of the method received further confirmation by some interesting incidental findings observed in five cases known to have been free of neurologic and psychiatric disease. Attention is called to the usefulness of this approach for the ultrastructural study of the brain in various pathologic situations of neurologic and/or psychiatric interest. Furthermore, the importance of this method as a means to obtain an ultrastructural baseline of human central nervous tissue in different age groups is briefly mentioned.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1435-1803
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Bei 28 Patienten mit arterieller Hypertonie und beginnender linksventrikulärer Funktionseinschränkung wurde die Hämodynamik in Ruhe und während Ergometerbelastung vor und 30 Minuten nach intravenöser Gabe von 0,6 mg Beta-Methyl-Digoxin untersucht. Mit Hilfe eines Swan-Ganz-Thermistor-Katheters wurden die Füllungsdrücke beider Ventrikel sowie das Herzzeitvolumen bestimmt. Die Änderung dieser Größen nach Digitalis zeigte keine einheitlich günstige Wirkung auf die Hämodynamik der untersuchten Patienten. Bei getrennter Betrachtung von 11 Hypertonikern mit koronarer Herzerkrankung (Gruppe I) und den übrigen 17 Patienten ohne klinische und/oder angiographische Zeichen einer koronaren Herzerkrankung (Gruppe II) ließ sich ein unterschiedliches hämodynamisches Verhalten nach Digitalis nachweisen: Bei Patienten derGruppe I nahm der durchschnittliche Pulmonalkapillar-druck (PAWP) in Ruhe und während Belastung nur gering und nicht signifikant von 8,7 mm Hg auf 7,4 mm Hg, bzw. von 27,6 mm Hg auf 26,4 mm Hg ab. Das Herzzeitvolumen (HZV) blieb weitgehend unbeeinflußt: Die durchschnittlichen Ruhewerte betrugen 5,9 L/min im Kontrollversuch und 5,8 L/min nach Digitalisierung. Die entsprechenden Belastungswerte unterschieden sich mit durchschnittlich 11,5 L/min gegenüber 11,1 L/min ebenfalls nicht signifikant. Bei Patienten derGruppe II konnte der Ruhewert des PAWP ebenfalls nur unwesentlich von durchschnittlich 8,8 mm Hg auf 7,2 mm Hg gesenkt werden. Dagegen kam es während Belastung zu einer deutlichen Besserung der linksventrikulären Funktion mit Reduktion des PAWP nach Beta-Methyl-Digoxin von 27,8 mm Hg auf 22,3 mm Hg (p〈0,01). Mit einer Ausnahme zeigte der PAWP bei dieser Patientengruppe eine Normalisierungstendenz. Das HZV wurde auch bei Patienten der Gruppe II durch Digitalis nicht signifikant beeinflußt: Die Durchschnittswerte waren vor Digitalis 6,2 L/min (Ruhe) und 13,4 L/min (Belastung), nach Digitalis 5,9 L/min (Ruhe) und 13,5 L/min (Belastung). Die möglichen Ursachen der unterschiedlichen Digitaliswirkung bei Patienten mit Hypertonie werden diskutiert.
    Notes: Summary Twenty-eight patients with hypertensive cardiovascular disease (HCD) and incipient myocardial dysfunction underwent hemodynamic studies at rest and during exercise before and 30 minutes after administration of 0.6 mg betamethyl-digoxin intravenously. Measurements were made during right heart catheterization with a balloon-tipped catheter. The hemodynamic changes after administration of digitalis did not demonstrate a consistent and uniform improvement of cardiac performance in all patients with HCD and myocardial dysfunction. When separating 11 patients with previous myocardial infarctions or documented coronary artery disease (CAD) (=Group I) from the remaining 17 subjects without clinical and/or angiographic signs of CAD (=Group II), there were significant differences in the hemodynamic response to digitalis: In Group I, pulmonary artery wedge pressure (PAWP) after digitalis decreased only slightly and insignificantly from 8.7 to 7.4 mm Hg at rest and from 27.6 to 26.4 mm Hg during steady state exercise. Cardiac output (CO) remained essentially unchanged with a tendency to decrease after digitalis: 5.9 vs. 5.8 L/min at rest and 11.5 vs. 11.1 L/min during exercise. At rest, even patients of Group II showed only minor decrease of PAWP from 8.8 to 7.2 mm Hg; during exercise these patients demonstrated marked improvement of cardiac performance with a significant decrease of PAWP after digitalis from 27.8 to 22.3 mm Hg (p〈0.01). With one exception, there was a more or less pronounced reduction of PAWP after the drug was given. No significant change of CO after digitalis was measured in this group: 6.2 vs. 5.9 L/min at rest and 13.4 vs. 13.5 L/min during exercise. The different hemodynamic patterns of responders and non-responders to the glycoside will be discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1435-1544
    Keywords: Key words AV-delay – dual chamber pacemaker – surface ECG ; Schlüsselwörter AV-Intervall – Zweikammer-Schrittmacher –¶Oberflächen-EKG
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die individuelle Anpassung der AV-Intervalle ist Voraussetzung für die hämodynamischen Vorteile der Zweikammerstimulation. Die bisher angewandten Methoden zur Optimierung der AV-Zeiten bedingen einen gewissen apparativen Aufwand und sind zeitintensiv. Eine einfache und schnelle Methode ist die approximative Einstellung der AV-Intervalle mit Hilfe des Oberflächen-EKG. Ziel dieser Arbeit ist die Vorstellung und die Validierung dieser neuen Methode.¶   Das optimale AV-Intervall (AVI) ist dann gegeben, wenn am Ende der atrialen Kontraktion die Mitralklappe durch den ventrikulären Druckanstieg geschlossen wird. Um dies bei Schrittmacher- Patienten zu erreichen, müssen die individuell unterschiedlichen atrialen und ventrikulären elektrophysiologischen Leitungszeiten berücksichtigt werden. Über das Oberflächen-EKG lassen sich die unterschiedlichen Leitungszeiten feststellen. Die intra- und interatriale Leitungszeit lässt sich vom Beginn des atrialen Stimulus bis zum Ende der P-Welle definieren. Der ventrikuläre Druckanstieg korrespondiert mit der Spitze des stimulierten Kammerkomplex (Beginn der isovolumetrischen Kontraktionszeit, ISVK) und ist abhängig von der interventrikulären Leitungszeit. Bei 100 Patienten, die keinen Herzschrittmacher tragen, wurde das Intervall vom Ende der P-Welle (linksatriale Erregung, EP) bis zum Gipfel der R-Welle (ISVK) in Ruhe und unter Belastung gemessen und ein altersbezogener Mittelwert von 100ms festgestellt, dieser dient als Normwert, wenn keine Überleitung vorhanden ist. Die approximierte optimierte AV-Zeit ist dann gegeben, wenn das Intervall vom Ende der P-Welle (linksatriale Erregung) bis Spitze stimulierter Kammerkomplex 100ms beträgt. Über einen einfachen Algorithmus lässt sich das optimierte AV-Intervall berechnen:¶   Es wird ein langes AVI programmiert und das Intervall vom Ende der nativen oder stimulierten P-Welle bis zur Spitze des stimulierten Kammerkomplex (EP/ISVK) bestimmt. Der gefundene Wert EP/ISVK wird nun vom langen AVI abgezogen, die 100ms Normwert werden nun addiert und man erhält das approximativ optimierte AVI.¶   Zur Validierung der beschriebenen Methode wurden 13 konsekutive Patienten (2 Frauen, 11 Männer, Durchschnittsalter 67±7,8 Jahre) eingeschlossen, die aus unterschiedlicher Indikation (7 Mal Sick Sinus Syndrom, 4 Mal AV Block 3, 2 Mal Zwei-Knotenkrankheit) einen DDD-Schrittmacher (Affinity, St. Jude Medical) erhielten. Etwa 8 Wochen nach der Implantation unterzogen sich alle Patienten einer PA Katheter-Untersuchung, um die AV-/PV-Zeiten des Schrittmachers im Hinblick auf das zu erzielende maximale Herzzeitvolumen (HZV) zu optimieren. Zur HZV-Messung wurde das Thermodilutionsprinzip angewandt.¶   Insgesamt wurden 17 vollständige hämodynamische Messungen (9-mal mit verschiedenen PV-, 8-mal mit verschiedenen AV-Zeiten) durchgeführt. Die Patienten Nr.10 bis 13 konnten sowohl im VDD- als auch im DDD-Modus untersucht werden.¶   Das minimal bestimmte optimale HZV betrug 3,5 l/min, das maximale 7,1 l/min und der Mittelwert betrug 5,62±0,98 l/min.¶   Bei allen Patienten fand sich dabei nicht nur eine einzige optimale AV-/PV-Zeit, sondern ein unterschiedlich breites Intervall von nebeneinanderliegenden AV-/PV-Zeiten, bei denen jeweils optimale HZV-Ergebnisse zu erzielen waren.¶   Der Vergleich der vom Oberflächen EKG ermittelten optimierten AV-/PV-Werte mit den hämodynamisch gemessenen optimierten AV-/PV-Intervallen zeigte eine statistisch signifikante Korrelation (0,825PVI, 0,982 AVI, P〈0,01). 16 von 17 Messungen liegen in einem Intervall, das hämodynamisch optimale HZV bzw. Schlagvolumina ermöglicht; nur einmal lag ein vom Oberflächen EKG ermittelter PV-Wert geringfügig (10 ms) außerhalb des als hämodynamisch optimal bestimmten Intervalls. Trotz der hier dargestellten ermutigenden Untersuchungsergebnisse sollten weitere Studien gerade auch im Vergleich mit den anderen Techniken der PV- bzw. AV-Zeit Optimierung den Stellenwert des hier dargestellten – aus dem Oberflächen-EKG entwickelten – Algorithmus weiter untersuchen.
    Notes: Summary The individual adjustment of the AV intervals is a prerequisite for the hemodynamic advantages of dual-chamber pacing. The methods for the optimization of the AV-Delay (AVD) applied so far are time intensive. A simple and fast method is the approximate adjustment of the AVD with the surface-ECG. The aim of this work is the conception and validation of this new method. The optimal AVD is given if at the end of the atrial contraction the mitral valve is closed by the ventricular increase of pressure. In order to achieve this with pacemaker patients, the individually different atrial and ventricular conduction times must be considered. The different conduction times can be determined from the surface-ECG. Intra- and interatrial conduction times can be defined by the beginning of the atrial spike up to the end of the p-wave. The beginning of ventricular pressure increase corresponds to the peak of the stimulated QRS complex (beginning of the Iso-Volumetric Contraction time, ISVC) and depends on the interventricular conduction time.¶   In the case of 100 patients, who did not receive a cardiac pacemaker, the interval at the end of the p-wave (left atrial excitation, EP) up to the peak of the r-wave (ISVC) during rest and exercise was measured and an age referred average value of 100ms determined; this serves as standard value if no AV-conduction is available. The approximated optimized AVD is given if the interval of the end at the p-wave to the peak of the QRS-Complex amounts to 100ms. By means of a simple algorithm, the optimized AVD can, thus, be calculated:¶   After programming a long AVD, the interval at the end of the native or paced p-wave up to the peak of the stimulated QRS-Complex (EP/ISVC) is determined. This value EP/ISVC is then taken from the long AVD, the 100ms standard value is added and one receives the approximately optimized AVD.¶   In order to validate the described method, 13 consecutive patients (2 female, 11 male, average age 67±7.8 years) were included, and received for different indication (7 sick sinus syndrome, 4 AV block III, 2 binode disease) a DDD pacemaker (Affinity, St. Jude Medical).¶   About 8 weeks after implantation all patients underwent a PA catheter investigation, in order to optimize the AV-/PV-Delay of the pacemaker regarding the maximum cardiac output (CO). For CO measurement the thermo dilution method was applied. Altogether 17 complete hemodynamic measurements (9 times with different PVDs, 8 times with different AVDs) were executed. The patients 10–13 could be examined both in the VDD and in the DDD mode.¶   The minimum determined CO amounted to 3.5 l/min, the maximal CO 7.1 l/min and the average value was 5.62±0.98 l/min. In all patients not only one optimal AVD was found but, moreover, a varied interval of AVDs with which optimal CO results could be obtained. The comparison of surface ECG optimized AVD with the PA catheter optimized AVD showed a statistically significant correlation (0.825PV, 0.982 AV, P〈0.01). Sixteen out of seventeen measurements were at an interval which enables hemodynamic optimal CO or stroke volume. Only one AVD determined from the surface ECG was situated slightly (10 ms) outside of a hemodynamic optimal determined AVD. Despite the encouraging test results represented here, further studies should examine the value of the new algorithm in comparison with the other techniques for AVD optimization.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...