    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 5613-5625 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A hybrid mass spectrometer consisting of a magnetic sector, two electric sectors, and a quadrupole mass filter (BEEQ) has been built for the study of polyatomic ion/surface collision phenomena over the energy range of a few electron volts to several keV. Primary ions are generated by electron ionization or by chemical ionization, and the first two sectors are used to deliver a monoenergetic beam of ions, of a selected mass-to-charge m/z ratio, to a decelerator which sets the desired collision energy. The target, which can be introduced into the system without breaking vacuum, is mounted on a goniometer and situated in an electrically shielded region in the center of a large scattering chamber which contains an electric sector and a quadrupole mass analyzer used for kinetic energy and mass measurements on the ejected ions. These analyzers rotate around the scattering center to allow selection of the scattering angle of ions leaving the surface.Ultimate pressures attainable in the main scattering chamber are below 10−9 Torr allowing molecular targets, such as self-assembled monolayers of alkyl thiols on gold, to be examined without surface contamination. Low-energy (20–100 eV) collisions of polyatomic ions are reported, and examples are given of the effects of collision energy and scattering angle on surface induced dissociation mass spectra. The kinetic energy of the inelastically scattered ions is also measured, and in some cases, the internal energy can be estimated, the two measurements together providing information on energy partitioning associated with surface collisions. For example, it is shown that n-butylbenzene molecular ions of 25 eV colliding with ferrocenyl-terminated self-assembled monolayer surfaces, rebound with 10 eV of recoil energy and 3 eV of internal energy.The remainder of the energy goes into the surface. The capability of the BEEQ instrument to provide data on ion/surface reactive collisions is also illustrated with reactions such as alkyl group transfer at self-assembled monolayer surfaces. In addition, data are given showing the ability of the system to provide information on the kinetic energy distributions of ions generated in the course of high-energy collisions at the surface. Mass analysis of the sputtered products provides the instrument with secondary-ion mass spectrometry capabilities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Palo Alto, Calif. : Annual Reviews
    Annual Review of Nuclear and Particle Science 20 (1970), S. 393-434 
    ISSN: 0066-4243
    Source: Annual Reviews Electronic Back Volume Collection 1932-2001ff
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    International Journal of Mass Spectrometry and Ion Processes 105 (1991), S. 225-238 
    ISSN: 0168-1176
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    International Journal of Mass Spectrometry and Ion Processes 114 (1992), S. 47-60 
    ISSN: 0168-1176
    Keywords: V-filament ion source ; analyzer focusing ; ion transmission efficiency ; isotope-ratio mass spectrometers.
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    International Journal of Mass Spectrometry and Ion Processes 84 (1988), S. 231-241 
    ISSN: 0168-1176
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Chemistry and Pharmacology , Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1130
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The photoplate detection system of a spark source mass spectrometer has been recently replaced by a detector array consisting of 20 separate small channeltrons for simultaneous ion counting of up to 20 trace elements. The new multi-ion counting – spark source mass spectrometry (MIC-SSMS) technique combines the advantages of conventional SSMS with modern on-line detection of elements. It has important analytical features, such as simple and fast solid-state sample preparation, high precision (about 1–2%) and accuracy (4%) using multielement isotope dilution, high sensitivity which leads to short measuring times (10–50 min) and low detection limits (about 0.001–0.01 μg/g).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Mathematical methods of operations research 12 (1968), S. 133-143 
    ISSN: 1432-5217
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics , Economics
    Description / Table of Contents: Zusammenfassung Die vorliegende Arbeit gibt einen Überblick über Algorithmen für die Verteilung der Ressourcen in Netzwerk-Projekten, die rechnerisch effizient erscheinen. Es werden 3 Fälle der Verteilung von Ressourcen betrachtet: „time-cost tradeoff“, „leveling of resources“ und „constrained resources“. Praktische analytische Methoden, die optimale Lösungen garantieren, existieren nur für das „time-cost tradeoff“ Problem. Heuristische Verfahren für Probleme mit Beschränkungen garantieren zwar keine optimalen Lösungen, führen aber eng an sie heran. Die relativen Vorteile, die durch heuristische Programme erzielt werden, können beim Fehlen empirischer Vergleichsmöglichkeiten großen Stils nicht abgeschätzt werden.
    Notes: Summary The paper surveys available algorithms for resource allocation in project networks that appear computationally efficient. Three cases of resource allocation are considered: time-cost tradeoff, leveling of resources, and constrained resources. Practical analytical methods that guarantee optimal solutions exist only for the time-cost tradeoff problem. Heuristic procedures for problems with constraints on resources do not guarantee but come close to optimal solutions. Relative advantages of heuristic algorithms cannot be assessed in the absence of large scale empirical comparisons.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 350 (1994), S. 642-644 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract Isotope dilution measurements of geological reference materials are described using a newly developed multi-ion counting (MIC) system for a spark source mass spectrometer. Compared with the conventional photoplate detection system, there are considerably improved analytical features of the MIC system, especially the high sensitivity which leads to short measuring times of 1 min to 1 h for trace element analysis on the μg/g — ng/g level.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...