Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 1 (1913), S. 383-393 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Zusammenfassung Es wird an einem einfachen hydrodynamischen Beispiel der Unterschied zwischen Potential und Wirbelfeld erläutert (§ 1) und diese Unterscheidung auf die Maxwellschen Gleichungen (in ihrer Integralform) angewendet (§ 2). Die Lösungen dieser Gleichungen werden aus den elementaren Gesetzen von Biot-Savart und Faraday aufgebaut und auf Systeme mit Selbstinduktion angewendet (§ 3). Dabei zeigt sich, daß die in üblicher Weise als EMK. bezeichnete Größe ihrem Ursprung nach eine Potentialdifferenz ist. Unter beständiger Diskussion der Feldverteilung werden Doppelleitung und Spule als Beispiele behandelt (§ 4). Ergänzungsweise wird die Anwesenheit von Eisen und der Einfluß von Kapazitäten diskutiert (§ 5). Auf energetische Fragen wurde naturgemäß nicht eingegangen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 2 (1913), S. 67-70 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 2 (1914), S. 313-326 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 59 (1981), S. 929-930 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 57 (1979), S. 1217-1223 
    ISSN: 1432-1440
    Keywords: Continuous PO2-measurement ; Intraarterial electrodes ; Microthrombosis ; Scanning electron microscopy ; Biocompatibility ; Kontinuierliche PO2-Messung ; Intraarterielle Elektroden ; Mikrothrombosen ; Rasterelektronenmikroskopie ; Biokompatibilität
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Die kontinuierliche Blutgasmessung mittels intraarterieller Elektroden stellt eine wesentliche Bereicherung intensivmedizinischer und anaesthesiologischer Überwachungsmöglichkeiten des pulmonalen Gasaustausches dar. Zur Beurteilung der Meßeigenschaften und der Komplikationsmöglichkeiten ist die Kenntnis des Verhaltens der Elektrodenoberfläche im Blutstrom erforderlich. Eine kommerziell erhältliche polarographische Elektrode zur intravasalen PO2-Messung wurde nach In-vitro- und In-vivo-Applikation rasterelektronenmikroskopisch untersucht. 14 Elektroden waren zur kontinuierlichen intraarteriellen PO2-Messung bei Patienten mit obstruktiven Atemwegserkrankungen und beatmeten Intensivpatienten über eine Dauer von 2–109 h eingesetzt worden. Bereits nach 2 h In-vivo-Meßdauer war fast regelmäßig ein filmartiger Proteinbelag der Elektrodenoberfläche zu erkennen. Mikrothrombotische Auflagerungen fanden sich in 2 Fällen, davon in einem Fall trotz Heparin-Behandlung. Daneben wurden Membranveränderungen der Elektrode in Form von Felderungen infolge kleinster Einrisse der Elektrodenoberfläche, ferner blasige Abhebungen und napfartige Einsenkungen beobachtet. — Diese Veränderungen sind wahrscheinlich überwiegend Folge der Trocknung des zuvor gequollenen Membranmaterials (Hydron), eines hydrophilen Polymers. Möglicherweise tritt ein Teil dieser Veränderungen bereits während der Messung auf. Die Untersuchungen sprechen in Verbindung mit anderen Studien für ein relativ geringes Thromboembolie-Risiko bei intraarterieller Applikation dieser Elektrode. Die Auflagerungen und Membranveränderungen beeinflussen wahrscheinlich die Einstellzeit, möglicherweise auch die Stabilität der Elektrode.
    Notes: Summary Continuous blood gas measurement by means of indwelling intraarterial electrodes facilitates and contributes to considerably improve the monitoring of pulmonary gas exchange in intensive care and anaesthesiology. Knowledge of the behaviour of the electrode surface in the blood stream is necessary to assess the characteristics of the measuring and the possible risks of complications. Scanning electron microscopic examinations were performed in a commercial-type polarographic PO2 electrode after in vitro and in vivo application. 14 electrodes were examined after continuous intra-arterial measurements in patients with chronic obstructive pulmonary disease and in intensive care patients. Duration of intra-arterial measurements was 2–109 h. Already after a measuring period of 2 h in nearly all cases a protein film was discovered on the electrode surface. Microthrombotic deposits were seen in 2 cases, in one of these despite of treatment with heparin. The electrode membrane showed a network of micro-cracks, small bubbles and dents. The membrane changes were probably the result of the drying process during the electron microscopic preparation, because the membrane material (Hydron) is hydrophil and swells during the measurement. Yet it cannot be excluded that these changes occur, in part, during the measurements. From these and other studies we conclude that the intra-arterial application of this electrode has a low risk of thromboembolic complications. The deposits on the electrode surface and the membrane changes may probably affect the response time and possibly also the stability of the electrode.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 33 (1955), S. 1105-1108 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 36 (1958), S. 20-22 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Zusammenfassung Mittelwerte und Streuung der AHG-Aktivität stimmen bei Knaben und Mädchen überein. Hiermit ist die Hypothese, nach der die normale Streuung der AHG-Aktivität durch eine X-chromosomale Allelenreihe bedingt wäre, unvereinbar. Konduktorinnen des Hämophilie-Gens zeigen wahrscheinlich eine leichte Verminderung der AHG-Aktivität. Diese Beobachtung spricht dafür, daß bei der Hämophilie nicht allein ein Mangel an AHG vorliegt, sondern ein funktionell minderwertiges Gen-Produkt.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Journal of molecular medicine 36 (1958), S. 683-684 
    ISSN: 1432-1440
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 101 (1967), S. 181-190 
    ISSN: 1432-1076
    Keywords: Syndaktylie ; Mißildung der Gliedmaßen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Eine totale Syndaktylie (Löffelhand) mit radioulnarer Synostose und ungewöhnlichen Papillarmustern der Handfläche bei zwei Brüdern wird beschrieben.
    Notes: Summary Total syndactyly and radio-ulnar synostosis with unusual dermatoglyphic pattern of the plasms is described in two brothers.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-1076
    Keywords: Median cleft face syndrome ; Frontonasal dysplasia ; Holoprosencephaly ; Agenesis of the corpus callosum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A premature female infant had the characteristic features of the median cleft face syndrome in association with holoprosencephaly, agenesis of the corpus callosum, hydrocephalus and choanal atresia. Whereas the nervous system is rarely affected in patients with the median cleft face syndrome, severe mental retardation has been reported in three previously published cases and is suggested in our own patient. All had an associated agenesis of the corpus callosum.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...