Standard spark gaps have lower time limits of gap recovery when testing with high repetition rate impulses and in high-current high-voltage multiple impulse testing. More important, they are not suitable for the generation of opposite-polarity successive impulses using conventional capacitive-type generation techniques. In this article, an improved design incorporating two rotating spark gaps is described. The new spark gap was used to test ZnO surge arresters with two successive impulses of currents up to 5 kA and voltages up to 50 kV. Time intervals as low as 10 ms were achieved between the two impulses. Both similar and opposite polarity tests were carried out successfully. © 1997 American Institute of Physics.