Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Cellular and molecular life sciences 34 (1978), S. 71-73 
    ISSN: 1420-9071
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Positive after-images (PAIs) evoked by low intensity stroboscopic flash are erased by voluntary large amplitude saccadic eye movements. The duration of the PAI is shortened by a Jendrassik manoeuvre. The results suggest that muscle spindle afferent impulses conducted centrally are involved in the erasure phenomenon. The duration of the PAI is modifiable by drugs. The social implications of PAI are considered briefly.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Documenta ophthalmologica 79 (1992), S. 117-124 
    ISSN: 1573-2622
    Keywords: Electro-oculogram ; near-ultraviolet (UVA) (365 nm) ; normal ; aphakic ; light source ; standards
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We recorded the electro-oculogram from 27 normal subjects by means of green and near-ultraviolet (UVA) stimulation. After a 40-minute dark-adaptation period, baseline responses were recorded. In response to the green stimulus, the electro-oculogram increased from this level by an average (± standard error of the mean) of 49.5% ±4.0%. Although the predicted scotopic effectiveness of the ultraviolet stimulus was more than 3 log units below that of the green stimulus, the near-ultraviolet-induced electro-oculogram increased to an average of 21.9% ±3.0% above baseline. This response cannot be due to lens fluorescence to the near-ultraviolet stimulus, since two aphakic subjects had electro-oculographic responses of 32% and 76% above baseline to near-ultraviolet stimuli. Neither the green nor the ultraviolet electro-oculogram changed significantly with age. These large responses to near-ultraviolet stimulation demonstrate the need for standardizing light sources for electro-oculographic testing because the degree of near-ultraviolet irradiance varies considerably according to their design characteristics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...