Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2161
    Keywords: Key words Lipoma ; Liposarcoma ; Soft tissue tumor ; MRI
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To investigate the septum-like structures in predominantly lipomatous tumors, by correlating fat-suppressed MR images with histopathologic findings. Design and patients. The MR findings of three cases of well-differentiated liposarcoma (atypical lipoma), one case of lipoma-like component of dedifferentiated liposarcoma, and nine cases of lipoma were analyzed. T1-, T2-, and fat-suppressed T1-weighted images after Gd-DTPA administration were obtained. Surgical specimens from five patients (four with liposarcoma and one with lipoma) were also scanned with a MR unit, and compared with the pathologic findings. Results and conclusions. Enhancement features of lipoma and liposarcoma were well visualized on fat-suppressed T1-weighted images after Gd-DTPA administration. The septum-like structures of liposarcoma are thick and enhanced considerably, while septa of lipoma are thin and enhanced only slightly. Pathologically, the septum-like structures of liposarcoma contained muscle fibers and the septa of lipoma represented fibrous capsule. Identification of well-enhanced septa in a predominantly lipomatous tumor helps to differentiate malignant tumors from lipomas. As the septum-like structures of liposarcoma contain a skeletal muscle component the tumor might need more extensive surgical procedures including resection of adjacent muscles.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Biomaterials 2 (1991), S. 1-12 
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The purpose of this study was to evaluate a biodegradable poly(L-lactide) (P—L—LA) screw for osteosynthesis under a load-bearing condition. A proximal tibial osteotomy on 25 rabbits was fixed with a biodegradable screw made of P—L—LA. A follow-up study was done at 1, 2, 4, 8, and 16 weeks. In another 25 rabbits, the tibial osteotomy was fixed with stainless steel (SUS) screws of the same size as the P—L—LA screws with a similar follow-up period. Radiographic, histological, microradiographic, and oxytetracycline-labeling studies showed healing of the osteotomy within 4 to 8 weeks. The displacement of frag-ments and the mass of newly formed bone around the screws were measured by histomorphometric analysis. There was no significant difference in the displacement of the fragments in these two groups and new bone was more abundantly detected in the P—L—LA group than in the SUS group. Histologically, no inflammatory lesion was detected in either group. All osteotomies united without delay and the displacement was minimal, although no external support was applied and the rabbits were allowed to move freely after the operation. The results of this study suggest a possible use for a P—L—LA screw in the clinical treatment of human bone fractures.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 26 (1992), S. 1553-1567 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Ultra-high-strength poly(L-lactide) (PLLA) rods were fabricated using a drawing technique. Rods with a diameter of 3.2 mm and a draw ratio of 2.5:1 showed initial bending strength and modulus values of 240 MPa and 13 GPa, respectively. The purpose of this study was to investigate the in vitro and in vivo degradation of PLLA rods with a draw ratio of 2.5:1. The greater the rod diameter, the longer the bending strength was maintained in phosphate buffered saline at 37°C. The bending strength retention of rods (diam. 3.2 mm) implanted in the subcutis of rabbits was almost equal to that of rods in the in vitro study, while those rods implanted in the medullary cavity of rabbit femora showed a slightly lower bending strength retention. Molecular weight was reduced to the greatest extent in the medullary cavity, followed by in the subcutis and in vitro. The weight of PLLA rods in the medullary cavity was reduced by 22% at 52 weeks and by 70% at 78 weeks after implantation. Histologically, no inflammatory or foreign body reaction was observed in the medullary cavity for 52 weeks. The drawn PLLA rods maintained a bending strength exceeding that of human cortical bone in the medullary canal for a period of 8 weeks, suggesting that the drawn PLLA rods may be useful in the repair of fractured human bones. © 1992 John Wiley & Sons, Inc.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...