Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 67 (1990), S. 6382-6388 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Rapid thermal processing has been utilized to sinter and anneal phase-pure and CuO-rich YBa2Cu3O7 fibers and woven fibers formed by melt spinning a powder/polymer composite. The optimum temperature for sintering the powders varies for the stoichiometric (1025 °C) and 5% CuO-rich fibers (1000 °C), but in both cases the temperature window is extremely narrow (±25 °C). Typical processing consists of a rapid heating (250 °C/s) of the fibers to the sintering temperature in 1 atm of pure oxygen, holding at temperature for 1 s and cooling over a period of 2–3 min. The resulting fibers are orthorhombic YBa2Cu3O7 with large Meissner and shielding fractions, have zero resistance up to 92 K, critical-current densities in zero applied field to 1100 A/cm2 at 76 K, and show clean grain boundaries by transmission electron microscopy. Despite the short processing times, microstructural analysis shows considerable grain growth and evidence of metastable congruent melting of oxygen-rich YBa2Cu3O7.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 83 (1998), S. 4589-4601 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A flexural plate wave resonator was constructed by patterning current lines on a silicon nitride membrane suspended on a rectangular silicon frame. Eigenmodes of the rectangular membrane were excited using Lorentz forces generated between alternating surface currents and a static in-plane magnetic field. Preferential coupling to a particular membrane mode was achieved by positioning current lines along longitudinal mode antinodes. An equivalent-circuit model was derived which characterizes the input impedance of a one-port device and the transmission response of a two-port device over a range of frequencies near a single membrane resonance. Experiments were performed to characterize the device's response to changes in dc magnetic field strength, ambient gas composition, gas pressure, and input power. © 1998 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1420-908X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The angiogenesis inhibitor AGM-1470 has recently been reported to inhibit collagen-induced arthritis in rats. To determine if the anti-arthritic effects of AGM-1470 might be due to T cell inhibition, we have studied its effects on T cell responsesin vitro. Responses of human cells to tetanus toxoid (TT), and those of murine splenocytes to staphylococcal enterotoxin (SE), mitogens or an mls difference were inhibited by AGM-1470. Responses of human cells to SE, OKT3 and PHA were all partially inhibited on day 2 (d2) but not d3, and in fact were augmented on d6–8. The amount of IL-2 in SEA cultures was augmented on d4 and d5. There were no differences in the expression of CD3, CD4, CD8, CD25, CD45RA, CD45RO, LFA-1, VLA-4 or VLA-6 in inhibited cultures, except for slight decreases in CD25 and CD45RO in TT cultures. These results indicated that the angiogenesis inhibitor AGM-1470 also modulates human and murine lymphocyte function.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1433-2981
    Keywords: Basophils ; Blood cells ; Chicken ; Heat stress
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The fine structure of blood cells, with particular reference to basophils, was studied in broiler chickens before and after they had been subjected to heat stress. Granule counts in basophils after heat treatment showed a significant reduction in their total numbers compared with pre-heat treatment. This depletion of granules corresponded with evidence of degranulation seen at the ultrastructural level. Of the three types of basophilic granules described, only the type I electron-dense, homogeneous variety of granule was significantly reduced in number. After heat stress, there was a significant increase in heterophil lobulation. In several birds there was also evidence of cytoplasmic fragmentation in the form of portions of cells containing granules but no nuclei, lying free in the circulation. Damaged mitochondria, not seen before heat treatment, were frequently observed in the cells. Monocytes also showed significant increases in cytoplasmic lipid droplets after heat stress compared with pre-heat treatment, suggesting the onset of possibly early fatty degeneration. However, there was no evidence of increased pseudopodia or pinocytotic activity in these cells. With heat stress, there was a significant reduction in the numbers of electron-dense granules in the small lymphocytes. Despite there being a smaller proportion of circulating eosinophils after heat stress, which was considered to be the result of an immediate stress response, no significant differences were evident between pre- and post-heat treatment in the cells. The red cells and thrombocytes from post-heat-stressed broilers were significantly longer and thinner compared with pre-heat treatment due possibly to dehydration. The dimensional and ultrastructural changes identified in the cells after heat stress question their effective functional ability in raising an immune response under such circumstances.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Cellular and molecular life sciences 37 (1981), S. 265-266 
    ISSN: 1420-9071
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Summary Maximum absorptive capacities (Vmax) for the jejunum and ileum corrected for the presence of an unstirred layer of water have been calculated for glycine, valine and methioninein vivo in fowls per unit surface area and per region. Vmax per cm2 showed that ileal enterocytes had a greater absorbing capacity than jejunal for glycine and valine but not for methionine. Vmax for glycine and valine, calculated for the whole jejunum and ileum, however, were not different but for methionine the jejunal value was 1.9 times greater than the ileal.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1572-9672
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The Plasma Wave Instrument on the Polar spacecraft is designed to provide measurements of plasma waves in the Earth's polar regions over the frequency range from 0.1 Hz to 800 kHz. Three orthogonal electric dipole antennas are used to detect electric fields, two in the spin plane and one aligned along the spacecraft spin axis. A magnetic loop antenna and a triaxial magnetic search coil antenna are used to detect magnetic fields. Signals from these antennas are processed by five receiver systems: a wideband receiver, a high-frequency waveform receiver, a low-frequency waveform receiver, two multichannel analyzers; and a pair of sweep frequency receivers. Compared to previous plasma wave instruments, the Polar plasma wave instrument has several new capabilities. These include (1) an expanded frequency range to improve coverage of both low- and high-frequency wave phenomena, (2) the ability to simultaneously capture signals from six orthogonal electric and magnetic field sensors, and (3) a digital wideband receiver with up to 8-bit resolution and sample rates as high as 249k samples s−1.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...