Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 107 (1985), S. 2622-2626 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Melbourne, Australia : Blackwell Science Pty
    The @island arc 10 (2001), S. 0 
    ISSN: 1440-1738
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Geosciences
    Notes: Abstract The temporal variation of seismic velocity near the Nojima Fault, which ruptured during the 1995 Kobe earthquake (Hyogo-ken Nanbu earthquake), was detected using an accurately controlled routine-operated seismic source (ACROSS). The source generates elastic waves by a centrifugal force of an eccentric mass rotating around an axis. The mass is driven with an AC servomotor whose angular position is accurately controlled with reference to a very accurate global positioning system (GPS) clock. The error of the mass’ position is less than 0.002 radian and does not accumulate. As a result, the source generates sinusoidal waves of very narrow spectral peaks enabling their detection with an excellent signal-to-noise ratio. Although the stability of the rotation is quite excellent, a large daily variation was found, which seems to be caused by changes in atmospheric temperature. The daily variation was 10% in amplitude and 0.1 radian in phase of the signal observed at the 800 m borehole seismometer. A significant variation was found to be due to that of coupling between the rotational source and the foundation made of reinforced concrete in which the source was situated. In order to make a correction on the signal of the 800 m borehole seismometer, the vibration of the foundation was measured and modeled assuming a rigid body movement. The correction successfully reduced the daily variation by approximately 90%, resulting in a variation of 1% in amplitude and 0.01 radian in phase. The phase variation of 0.01 radian corresponds to 100 μs and less than 0.1% in velocity over 1000 m between the source and the receiver.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...