Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of the American Water Resources Association 32 (1996), S. 0 
    ISSN: 1752-1688
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Notes: : A variety of management options are used to minimize losses of nitrogen (N), phosphorus (P), and other potential pollutants from agricultural source areas. There is little information available, however, to indicate the effectiveness of these options (sometimes referred to as Best Management Practices, or BMPs) on basin scales. The objective of this study was to assess the water quality effectiveness of BMPs implemented in the 3240 ha Lincoln Lake basin in Northwest Arkansas. Land use in the basin was primarily forest (34 percent) and pasture (56 percent), with much of the pasture being regularly treated with animal manures. The BMPs were oriented toward minimizing the impact of confined animal operations in the basin and included nutrient management, dead bird composter construction, and other practices. Stream flow samples (representing primarily base flow conditions) were collected bi-weekly from five sites within the basin from September 1991 through April 1994 and analyzed for nitrate N (NO3-N), ammonia N (NH3-N), total Kjeldahl N (TKN), ortho-P (PO4-P), total P (TP), chemical oxygen demand (COD), and total suspended solids (TSS). Mean concentrations of PO4-P, TP, and TSS were highest for subbasins with the highest proportions of pasture land use. Concentrations of NH3-N, TKN, and COD decreased significantly with time (35–75 percent/year) for all sub-basins, while concentrations of other parameters were generally stable. The declines in analysis parameter concentrations are attributed to the implementation of BMPs in the basin since (a) the results are consistent with what would be expected for the particular BMPs implemented and (b) no other known activities in the basin would have caused the declines in analysis parameter concentrations.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of the American Water Resources Association 33 (1997), S. 0 
    ISSN: 1752-1688
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Notes: : Agricultural practices such as cattle grazing and animal manure application can contribute to relatively high runoff concentrations of fecal coliform (FC) and fecal streptococcus (FS). Available information, however, is inconsistent with respect to the effects of such practices as well as to measures that can discriminate among candidate sources of FC and FS. The objective of this study was to assess the effects of grazing, time of year, and runoff amounts on FC and FS concentrations and to evaluate whether FCIFS concentration ratios are consistent with earlier values reported as characteristic of animal sources. Runoff from four Northwest Arkansas fields was sampled and analyzed for fecal coliform (FC) and fecal streptococcus (FS) for nearly three years (1991–1994). Each field was grazed and fertilized, with two fields receiving inorganic fertilizer and two receiving animal manure. Runoff amount had no effect on runoff concentrations of FC or FS. There were no consistent relationships between the presence of cattle and FC and FS runoff concentrations. Both FC and FS concentrations were affected by the season during which the runoff occurred. Higher concentrations were observed during warmer months. Runoff FC concentrations exceeded the primary contact standard of 200 cfu/100 mL during at least 89 percent of all runoff events and the secondary contact standard of 1000 cfu/100 mL during at least 70 percent of the events. Ratios of FC to FS concentrations varied widely (from near zero to more than 100), confirming earlier findings that FC/FS ratios are not a reliable indicator of the source of FC and FS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...