Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 9 (1999), S. 1625-1628 
    ISSN: 1432-1084
    Keywords: Key words: Clear-cell chondrosarcoma ; Larynx ; Computed tomography ; Inner surface image ; Surface-rendering image
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. A case of a large low-grade mixed clear-cell and conventional chondrosarcoma of the larynx is reported involving the paraglottic space, the cricoid and thyroid cartilage and characterized by an unusual long clinical course over 22 years, although multiple recurrences occurred without developing metastases. Computed tomography suggests diagnosis by detecting calcifications and adequately demonstrates the extension of the tumor. Innersurface and surface-rendering images document the airway stenosis in all directions. The unusual feature of this case consists in the peculiar histopathological differentiation of the observed chondrosarcoma showing a large clear-cell component.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Mehrschicht-Spiral-CT ; Mehrzeilen-Spiral-CT ; Aortenerkrankungen ; Key words Multi-slice helical CT ; Aortic diseases
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Acute diseases of the central arteries require an immediate investigation. An efficient, fast and reliable diagnosis is necessary because of the high mortality, if the patient remains untreated. These requirements are perfectly fulfilled by the new CT-techniques. Methods. Suspected aortic diseases were examined with a new multi-slice helical CT. The thoracic or the abdominal aorta as well as the entire vascular tree from the supraaortic branches to the inguinal arteries were investigated with different CT protocols. The slice-thickness and the scan mode were changed while the total examination time was kept constant for the first two groups. In the third group a monophasic examination was compared to a biphasic one. Results. In the diagnosis of acute aortic diseases multi-slice helical CT proved to be a fast and reliable method with all scan protocols. The objective measurements of contrast homogeneity and image quality were comparable in the first two groups. The monophasic contrast medium injection protocol was superior to the biphasic administration mode. Conclusions. Multi-slice helical CT appears to be a very effective approach for the diagnosis of acute aortic diseases and seems to be the new gold standard.
    Notes: Zusammenfassung Akute Erkrankungen der Aorta im Körperstamm stellen eine lebensbedrohliche Situation für den betroffenen Patienten dar, so daß ein rasches Handeln zwingend erforderlich ist. Voraussetzung hierfür ist eine leistungsfähige, schnelle und zuverlässige Diagostik, die von der neuen CT-Technik in nahezu idealer Weise realisiert werden kann. Methoden: Bei klinischem Verdacht auf eine Aortenerkrankung wurden Untersuchungen mit einer neuen Mehrzeilen-Spiral-CT (MZ-SCT) durchgeführt. Die Aorta thoracalis, die Aorta abdominalis oder der gesamte Gefäßbaum von den supraaortalen Ästen bis zu den Inguinalarterien wurden mit verschiedenen Protokollen untersucht. In den ersten beiden Gruppen wurden bei konstanter Untersuchungszeit die Schichtdicke und die Tischvorschubgeschwindigkeit variiert. In der dritten Gruppe wurde eine monophasische mit einer biphasischen Untersuchung verglichen. Ergebnisse: In der Diagnostik von aortalen Erkrankungen erwies sich die MZ-SCT als schnelle und verläßliche Methode mit allen Protokollen. Die objektive Messung der Kontrasthomogenität und die subjektiven Abbildungsqualitäten waren in den ersten beiden Gruppen vergleichbar. Das monophasische Vorgehen war der biphasischen Untersuchung überlegen. Schlußfolgerung: Die MZ-SCT ist bei Anwendung geeigneter Untersuchungsprotokolle heute der Goldstandard in der Diagnostik akuter Aortenerkrankungen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...