Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1084
    Keywords: Key words: Breast neoplasms ; Breast MR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. The objective of this study was to assess the value of contrast-enhanced dynamic breast imaging in patients with carcinoma of unknown primary (CUP). Fourteen patients presenting with metastatic disease compatible with breast cancer (axillary lymph node metastasis: n = 6; supraclavicular lymph node metastasis: n = 1; bone metastasis: n = 3; liver metastasis: n = 3; lung metastasis: n = 1), who had no evidence of tumor in X-ray mammograms and ultrasound, underwent bilateral dynamic breast MR imaging. Suspicious lesions were localized preoperatively using a stereotactic device for MR-guided localization procedures. Magnetic resonance imaging revealed suspicious lesions in 9 of 14 patients. Histopathology revealed invasive carcinoma of the breast in 6 of these patients. Two enhancing lesions were fibroadenomas; one proved to be sclerosing adenosis. In 5 patients MR imaging showed no abnormality. Follow-ups performed up to 1 year after initial treatment revealed no breast cancers in these 5 patients. In patients with metastatic disease of unknown primary, MRI of the breast depicts the primary in a considerable number of cases with normal conventional evaluation.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Der Radiologe 40 (2000), S. 233-239 
    ISSN: 1432-2102
    Keywords: Schlüsselwörter Virtuelle Endoskopie ; Spiral-CT ; Obere Luftwege ; Untersuchungsprotokoll ; Key words Virtual endoscopy ; Helical computed tomography ; Upper airway ; Scanning protocol
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Purpose: The technical conditions, the optimized scanning protocols and the facilities of virtual endoscopy (VE) are presented in an overview. Methods: Phantom studies showed that, for a single-row-detector helical CT, collimation of 3.0 mm combined with pitch of 1.5 provided an optimal compromise between image quality and the scan duration per breath-hold. A multi-row-detector helical CT re- quires only a fraction of the scanning time. This is especially important for patients with dyspnea. Results: The threshold-dependent virtual endoscopic surface rendering is a reliable and rapidly practicable reconstruction algorithm for the imaging of the upper airway. Conclusions: The VE technique is suitable for the imaging of space-occupying tumors and restricted stenoses. With VE follow-up examinations can be performed non-invasively and interventional procedures can be pre-pared in an optimal way. Because of the computed tomographic data acquisition the structure of the mucosa is not assessable and there is no opportunity to obtain a biopsy specimen.
    Notes: Zusammenfassung Ziel: Die technischen Voraussetzungen, die optimierten Untersuchungsprotokolle und die diagnostischen Möglichkeiten der Virtuellen Endoskopie (VE) der oberen Luftwege werden in einer Übersicht vorgestellt. Methode: Phantomstudien konnten nachweisen, dass für ein 1-Zeilen-Spiral-CT-Gerät eine Kollimation von 3,0 mm kombiniert mit einem Tischvorschubsfaktor von 1,5 ein optimierter Kompromiss zwischen der Bildqualität und der tolerablen Untersuchungsdauer pro Atemanhaltephase ist. Ein Mehrzeilen-Spiral-CT der neuesten Generation benötigt bei einer vergleichbaren räumlichen Auflösung nur noch einen Teil der Akquisitionszeit, was insbesondere bei Patienten mit Dyspnoe die Durchführung der Untersuchung vereinfacht. Ergebnisse: Die schwellenwertabhängige virtuell endoskopische Oberflächendarstellung (surface rendering) ist für die Abbildung der oberen Luftwege ein verlässlicher und schnell einsetzbarer Rekonstruktionsalgorithmus. Schlussfolgerungen: Die VE bietet sich für die Darstellung raumfordernder Prozesse und umschriebener Stenosen an. Verlaufs- und Therapiekontrollen können mit der VE nichtinvasiv durchgeführt und interventionelle Maßnahmen optimal geplant werden. Aufgrund der computertomographischen Datenakquisition kann die Struktur der Mukosa nicht beurteilt werden. Ferner fehlt die Möglichkeit zur bioptischen Probeentnahme.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...