Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 2000 (2000), S. 153-157 
    ISSN: 1434-1948
    Keywords: Aluminum ; Ab initio calculations ; Isomers ; Intramolecular donor-acceptor systems ; Chemistry ; General Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Three aluminum compounds Ar*AlBr2 (1), Ar*AlBrtBu (2), and Ar*2AlBr (3), incorporating the chiral ligand Ar* = 2-[1-(S)-Me2NCH(Me)]C6H4, have been synthesized by salt metathesis reactions and have been characterized by multinuclear NMR (1H, 13C, and 27Al), mass spectrometry, and elemental analysis. The molecular structure of compound 3 has been determined by a single-crystal X-ray analysis (space group P212121). Alane 2 exists as a temperature-independent equilibrium mixture of two diastereomers in solution (ratio 45:55); results of NOE experiments on 2 are discussed. Only one isomer was found for compound 3 in solution and its dynamic behavior has been investigated by variable-temperature NMR methods; a ΔH of 56.6(4) kJ mol-1 and a ΔS of -0.79(1) J K-1mol-1 were deduced from band-shape analysis of the 1H-NMR signals of the N-bound methyl groups.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1615-3146
    Keywords: Kerspintomographie ; Kollateralbandruptur ; Knorpelläsion ; Hochauflösende Oberflächenspule ; Magnetic resonance imaging ; Collateral ligament rupture ; Cartilage lesion ; High-resolution coil
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Aim of this study was the evaluation of a prototype of a new high-resolution MRI coil for the detection of finger trauma. The practicability of this new coil for the assessment of traumatic lesions of the finger joints and the diagnostic value of this new method in clinical practice was assessed. Twenty patients between 13 and 50 years of age (mean 28 years) were examined with a 1.5-T whole-body-imager Magnetom SP 63 scanner (Siemens, Erlangen, Germany). A prototype of a high-resolution MRI coil with a diameter of 2.5 cm was used. T1- and T2-weighted images with an in plane resolution of 0.I95 x 0.098 mm were acquired. Bone structures, joint cartilage and capsule, ligaments, tendons and soft tissue alterations were assessed. All 19 patients with pathological changes at the finger joints had a joint effusion. With MR imaging, fractures were detected in almost all patients, compared with the X-ray examinations. Cartilage contusion showed high signal intensity. The collateral ligaments could best be assessed in the transversal, and ligament ruptures in the coronal plane. Hemorrhage in the tendon showed an increased signal intensity in T1- and T2-weighted, edema only in T2-weighted images. Especially traumatic lesions of cartilage and of ligaments can be sufficiently assessed by the high-resolution MRI due to its high anatomic resolution compared to common methods like X-ray. High-resolution MRI is practicable in clinical routine.
    Notes: Zusammenfassung Ziel der vorliegenden prospektiven Untersuchung war es, die Wertigkeit der hochauflösenden Kernspintomographie mittels einer speziellen Oberflächenspule in der Beurteilung von traumatischen Veränderungen der Fingergelenke zu evaluieren. Ferner sollte die Praktikabilität der Methode in der klinischen Routine überprüft werden. Es wurden 20 Patienten im Alter zwischen 13 und 50 Jahren (im Mittel 28 Jahre) an einem 1,5-T-Ganzkörpertomographen (Magnetom SP 63, Firma Siemens, Erlangen) untersucht. Als Spule wurde ein Prototyp einer hochauflösenden Oberflächenspule mit einem Durchmesser von 2,5 cm benutzt. T1- und T2-gewichtete Sequenzen mit einer maximalen Auflbsung in der Bildebene von 0,195 x 0,098 mm wurden zur Beurteilung von Knochen, Gelenkknorpel und -kapsel, der Sehnen und des Weichteilgewebes akquiriert. Kernspintomographisch fand sich bei 19 Patienten ein pathologischer Befund. Bei all diesen Patienten konnte ein Gelenkerguß nachgewiesen werden. Knöcherne Absprengungen, die anhand konventioneller Röntgenaufnahmen diagnostiziert wurden, zeigten sich kernspintomographisch als dislozierte signalreiche Strukturen. Gelenkknorpelkontusionen stellten sich hyperintens dar. Zur Beurteilung der Kollateralbānder eignete sich vor allem die koronare Schichtebene, da in dieser die Kollateralbdnder per continuitatem darstellbar sind. Sehneneinblutungen wiesen eine Signalerhöhung in T1- und T2-Wichtung auf. Ödeme der Weichteile und Bandstrukturen imponierten in T2-gewichteten Aufnahmen als signalreiche Strukturveränderungen. Aufgrund der hohen anatomischen Detailerkennbarkeit eignet sich die hochauflbsende Kernspintomographie als ergänzendes diagnostisches Verfahren zur nichtinvasiven Diagnostik von traumatischen Knorpel- und Bandläsionen. Unter Berücksichtigung des Zeitaufwandes handelt es sich dabei um eine im klinischen Alltag praktikable Methode.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2022-07-19
    Language: English
    Type: article , doc-type:article
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...