    Copenhagen : Munksgaard International Publishers
    Clinical oral implants research 12 (2001), S. 0 
    ISSN: 1600-0501
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Abstract: The aim of the present study was to evaluate the reproducibility of probing depth (PD) and vertical attachment level (PAL-V) measurements at endosseous implants. Twenty partially edentulous patients who had received 44 Frialit-2 and 30 Astra implants between 1994 and 1996 were examined. At all teeth and implants, clinical parameters (GI, PlI, PD, PAL-V) were measured at 6 sites using the flexible plastic version of the universal explorer TPS probe. At the implants and at teeth that were in similar locations compared to the implants, PD and PAL-V measurements were repeated. For each of the 20 probes that had been used for clinical examination of the 20 patients, the probing force was assessed using a precision balance. As a measure of intraexaminer reproducibility, the following standard deviations of single PD and PAL-V measurements were calculated: Frialit-2: 0.71/0.74 mm; Astra: 0.72/0.75 mm; tooth: 0.59/0.57 mm (PD/PAL-V). Stepwise multiple regression analysis revealed implant/tooth position and GI to influence PD and PAL-V measurement error (P〈0.001). At anterior teeth, a lower variability was observed than at posterior teeth (P〈0.001). PD and PAL-V measurement error were higher at implants than at teeth and influenced by patients. The respective models explained 13% and 17% of the variability of the dependent variable (PD/PAL-V), respectively. Intraexaminer variability of PD and PAL-V measurements at implants tended to be higher than at teeth. Multivariate analysis of variance revealed probe and probe holder to statistically significantly (P〈0.001) influence probing force. However, the differences in probing force between the various probe heads were very small. They reached a maximum of 0.054 N between probe 3 and 14 and may be looked upon as clinically irrelevant.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1600-0501
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Abstract: The aim of the study was to compare the bone mineral apposition rate (BMAR) of immediately loaded implants with an unloaded control during the early healing phase in the partially edentulous mandible. In seven mini pigs, three premolars and the first molar were removed in the left mandible. Three months later, five implants were installed. Four implants received a fixed provisional restoration and were loaded immediately. The most anterior implant was used as unloaded control. Polychromatic fluorescence labelling was performed to assess the BMAR. After 4 months, the implants were retrieved together with the adjacent bone. Histological specimens were prepared and subjected to a fluorescence microscopic and histomorphometric analysis. Two provisional restorations were found partially lost at the end of the observation period. One implant that had lost the splinting fixation showed soft connective tissue healing. The BMAR did not differ statistically significantly between loaded and unloaded implants and within the single groups during the observation period (BMARloaded days 14−42=1.8±0.2 μm/d, BMARloaded days 42−70=1.8±0.1 μm/d, BMARloaded days 70−98=1.6±0.1 μm/d, pBMARloaded days 14–42/42–70/70–98=0.156, BMARunloaded days 14−42=1.7±0.1 μm/d, BMARunloaded days 42−70=1.8±0.2 μm/d, BMARunloaded days 70−98=1.6±0.4 μm/d, pBMARunloaded days 14–42/42–70/70–98=0.368, pBMARloaded/unloaded days 14–42=0.073, pBMARloaded/unloaded days 42–70=0.098, pBMARloaded/unloaded days 70–98=0.262). Four months after implant placement, the bone-to-implant contact was 77.8±17.3% for the loaded and 78.0±5.8% for the unloaded implants (P=0.753). Immediate loading does not affect the bone mineral apposition rate when compared with unloaded implants. Rigid splinting seems to be the crucial factor for implant success. Uncontrolled masticatory forces can cause failure after partial loss of the provisional restoration.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit