ISSN:
0021-8995
Keywords:
Chemistry
;
Polymer and Materials Science
Source:
Wiley InterScience Backfile Collection 1832-2000
Topics:
Chemistry and Pharmacology
,
Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
,
Physics
Notes:
An on-line sensor for estimating conversion from measurements of ultrasound propagation velocity in emulsion polymerizations has been developed. The sensor does not require a sampling circuit, because it can be directly plugged in the reacting mixture. The performance of the sensor has been tested by comparison with off-line gravimetric measurements of conversion under various operating conditions. These include the homopolymerization of methyl methacrylate and vinyl acetate, with different values of the monomer to water ratio and the initial concentrations of emulsifier and initiator. The results obtained using either an empirical calibration curve or a suitable a priori model indicate excellent reliability of the sensor with somewhat lower accuracy at low conversion values, i.e., when monomer droplets are present. © 1995 John Wiley & Sons, Inc.
Additional Material:
12 Ill.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1002/app.1995.070571110
Permalink