Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 13 (1967), S. 231-236 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: An instrument based on the Burnett method for determining gas compressibility at high temperature and high pressure was constructed. An estimate of the accumulated measurement errors indicate the data should be accurate to eight parts in 10,000. The instrument was calibrated up to 1,000 lb./sq.in. with helium at 200° and 300°C. The average absolute difference between the experimental and the smoothed helium compressibility factor data was 4 and 6 parts/100,000 for the 200° and 300°C. isotherms, respectively. Compressibility factor data for methyl chloride from 200° to 350°C. at 25°C. intervals and at pressures to 5,000 lb./sq.in. are reported. Second virial coefficients for helium and methyl chloride were also obtained.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-2: Polymer Physics 6 (1968), S. 813-823 
    ISSN: 0449-2978
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: The phase equilibria in polymer-liquid 1-liquid 2 ternary systems have been calculated on the basis of the Flory-Huggins theory of polymer solutions. A new approximation method based on the “cluster” concept has been introduced for mixed solvents comprising a solvent and a nonsolvent. This concept has been verified with polystyrene-solvent-methanol systems.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 12 (1968), S. 1775-1779 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The turbidimetric titration method of determining theta conditions developed by Elias and modified by Cornet and van Ballegooijen has been extended and generalized for different types of polymer-solvent-nonsolvent systems. The modified procedures for the determination of theta compositions have been verified with the following systems: polystyrene-cyclohexane-n-hexane, polystyrene-cyclohexane-n-butanol, and polystyrene-toluene-nonsolvent.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 12 (1968), S. 1803-1805 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 0021-9304
    Keywords: bone morphogenetic protein ; bone regeneration ; critical size defect ; rabbit ; biomechanics ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The study objective was to determine the mechanical integrity and radiopacity of regenerated bone within critical-sized defects (CSDs) in radii of rabbits using recombinant human bone morphogenetic protein 2 (rhBMP-2) with a porous, biodegradable poly(D,L-lactic acid) (PDLLA) carrier (designated PLA). Twenty millimeter, unilateral radial ostectomies were created in 96 skeletally mature New Zealand white rabbits. The rabbits were randomly assigned to six treatment groups with two euthanasia periods. Treatment groups included unfilled defect (n = 8), segmental autograft (n = 8), PLA + 0 μg rhBMP-2 (n = 8), PLA + 17 μg rhBMP-2 (n = 8), PLA + 35 μg rhBMP-2 (n = 8), and PLA + 70 μg rhBMP-2 (n = 8). The radiopacity was significantly greater for the 35- and 70-μg rhBMP-2 groups at 4 weeks compared to unfilled controls, PLA only, and 17-μg rhBMP-2 groups and equivalent to the autograft. At 8 weeks all groups receiving rhBMP-2 were equivalent to the autograft and significantly greater than unfilled defects and PLA alone. Similarly, the biomechanical analysis indicated significantly greater torque at failure for the 35-μg rhBMP-2 group compared to all other groups at 4 weeks. By 8 weeks all groups receiving rhBMP-2 and autograft had significantly greater torque than unfilled controls and PLA alone. These radiomorphometric and biomechanical results indicate PLA may be a suitable carrier for rhBMP-2 used for skeletal regeneration. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 43: 365-373, 1998
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 13 (1969), S. 253-255 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 12 (1968), S. 2359-2370 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The solubility parameters of sixteen polymers have been determined by the turbidimetric titration method. The results agree well with the reported values obtained from swelling and viscosity measurements. The method is sensitive to the choice of nonsolvents and to small changes in the copolymer composition.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science Part A-1: Polymer Chemistry 5 (1967), S. 1671-1681 
    ISSN: 0449-296X
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Turbidimetric titrations have been made on polystyrene and poly-o-chlorostyrene in a series of solvents to deduce the solubility parameters of polymers from the Flory-Huggins interaction parameter χ. The assigned solubility parameter for polystyrene agrees well with the reported values obtained from swelling measurements. Brief discussion of the exceptional behavior in the solvent powers of paraffins is given.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...