Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0378-1119
    Keywords: Recombinant DNA ; genomic library ; genomic organization ; in vitro translation ; phage λ vectors ; thylakoid lumen ; transcription start point ; transit peptide
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 8 (2001), S. 3824-3832 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The transport of ground-state hydrogen atoms in the expansion of a thermal hydrogen plasma created by a cascaded arc is studied by means of two-photon absorption laser induced fluorescence. The low-dissociation degree measured at the source exit implies that H atoms flow in a H2 environment. It is shown that the H atom expansion pattern is in disagreement with the neutral gas supersonic expansion theory. Indeed the transport of H atoms in the plasma jet is strongly influenced by surface-recombination processes. Because of the large density gradients between the core of the jet and its surroundings induced by the recombination of H atoms at the reactor walls, hydrogen atoms diffuse out of the plasma jet in the course of the expansion. When the surface loss probability is high, i.e., the combination of a large wall-recombination probability with a long residence time, the losses of radicals by diffusion cannot be avoided even when the mass of the carrier gas is close to the mass of the radical. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We report on quantitative, spatially resolved density, temperature, and velocity measurements on ground-state atomic hydrogen in an expanding thermal Ar–H plasma using two-photon excitation laser-induced fluorescence (LIF). The method's diagnostic value for application in this plasma is assessed by identifying and evaluating the possibly disturbing factors on the interpretation of the LIF signal in terms of density, temperature, and velocity. In order to obtain quantitative density numbers, the LIF setup is calibrated for H measurements using two different methods. A commonly applied calibration method, in which the LIF signal from a, by titration, known amount of H generated by a flow-tube reactor is used as a reference, is compared to a rather new calibration method, in which the H density in the plasma jet is derived from a measurement of the two-photon LIF signal generated from krypton at a well-known pressure, using a known Kr to H detection sensitivity ratio. The two methods yield nearly the same result, which validates the new H density calibration. Gauging the new "rare gas method" by the "flow-tube reactor method," we find a krypton to hydrogen two-photon excitation cross section ratio σKr(2)/σH(2) of 0.56, close to the reported value of 0.62. Since the H density calibration via two-photon LIF of krypton is experimentally far more easy than the one using a flow-tube reactor, it is foreseen that the "rare gas method" will become the method of choice in two-photon LIF experiments. The current two-photon LIF detection limit for H in the Ar–H plasma jet is 1015 m−3. The accuracy of the density measurements depends on the accuracy of the calibration, which is currently limited to 33%. The reproducibility depends on the signal-to-noise (S/N) ratio in the LIF measurements and is orders of magnitude better. The accuracy in the temperature determination also depends on the S/N ratio of the LIF signal and on the ratio between the Doppler-width of the transition and the linewidth of the excitation laser. Due to the small H mass, the current linewidth of the UV laser radiation is never the accuracy limiting factor in the H temperature determination, even not at room temperature. Quantitative velocity numbers are obtained by measuring the Doppler shift in the H two-photon excitation spectrum. Both the radial and axial velocity components are obtained by applying a perpendicular and an antiparallel excitation configuration, respectively. The required laser frequency calibration is accomplished by simultaneously recording the I2 absorption spectrum with the fundamental frequency component of the laser system. This method, which is well-established in spectroscopic applications, enables us to achieve a relative accuracy in the transition frequency measurement below 10−6, corresponding to an accuracy in the velocity of approximately 200 m/s. This accuracy is nearly laser linewidth limited. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 81 (2002), S. 418-420 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The generation of ammonia from atomic hydrogen and nitrogen has been demonstrated by means of cavity enhanced absorption spectroscopy. The atomic species are produced in a thermal plasma source in which plasma is created from mixtures of hydrogen and nitrogen. It is shown that for large atomic flux conditions, 2% of the hydrogen and nitrogen can be converted to ammonia. The process in which the ammonia molecules are formed from atomic radicals at the fully covered surface is called plasma-activated catalysis. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Molecular biology reports 14 (1990), S. 209-210 
    ISSN: 1573-4978
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Molecular biology reports 12 (1987), S. 150-150 
    ISSN: 1573-4978
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...