Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 25 (1931), S. 747-758 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 27 (1933), S. 99-104 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Electrical engineering 26 (1932), S. 409-418 
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Notes: Zusammenfassung Auf Grund der gewonnenen Resultate kann man den Mechanismus des Überschlags im homogenen Felde sich etwa folgendermaßen vorstellen: Bei vollkommen trockenem Isolator und gut anliegenden Elektroden geschieht der Überschlag genau bei derselben Spannung wie der Luftdurchschlag, die beiden sind folglich identisch. Falls die Oberfläche des Isolators feucht ist, so nimmt die Überschlagspannung ab, und zwar aus folgendem Grunde: Gleichzeitig mit dem Einschalten der Spannung und dem Einsetzen des Stromes beginnt eine Umladung der Oberfläche des Isolators, infolge der die Feldstärke an den Elektroden, hauptsächlich an der Anode vergrößert wird. Bei den hohen in Sprache kommenden Spannungen kann sich eine solche Umladung schnell genug vollziehen. Nach einiger Zeit nach dem Anlegen der Spannung erweist sich das ursprünglich annähernd homogene Feld als stark verzerrt, die Stoßionisation nimmt zu und die Überschlagspannung wird herabgesetzt. Im Fall von einem schlechten Anliegen der Elektrode an den Prüfling bewirkt die sich dabei ausbildende Inhomogenität des elektrischen Feldes, daß die Überschlag-spannungen auch bei trockener Oberfläche gegenüber der Durchschlagspannungen stark herabgesetzt sind.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-0487
    Source: Springer Online Journal Archives 1860-2000
    Topics: Electrical Engineering, Measurement and Control Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Der Anaesthesist 47 (1998), S. 339-347 
    ISSN: 1432-055X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-055X
    Keywords: Schlüsselwörter Cell-Saver ; intraoperative Autotransfusion ; radikale Prostatektomie ; Tumorzellen ; Urinkontamination ; Key words Cell saver ; Intraoperative autotransfusion ; Tumour cells ; Urine contamination ; Radical prostatectomy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Abstract Intraoperative autotransfusion (MAT), preoperative autologous blood donation, and preoperative normovolaemic haemodilution are three different methods to avoid homologous blood transfusion during surgical procedures. The controversial use of MAT via cell saver in tumour surgery as well as contamination of the operative field with urine illustrate the particular difficulties of autologous blood transfusion in connection with radical prostatectomy. We investigated changes in the osmotic resistance of the retransfused red blood cells (RBC), bacterial contamination, changes in coagulation parameters, and the presence of tumour cells. Patients and methods: After written informed consent, 24 patients who presented for radical prostatectomy were randomly allocated to either a group that used MAT or a group that used homologous transfusion. The patients received „balanced anaesthesia” with midazolam, fentanyl, atracurium, and nitrous oxide/oxygen. The analysed parameters from the preoperative period to the 3rd postoperative day are shown in Table 1. The Haemonetics 3 Plus Cell Saver was used for autotransfusion. Results: Our results showed that the haematologic parameters, coagulation factors, and serum chemistry did not differ between the two groups (Tables 2–4). However, there were significant differences during the investigated period. The osmotic resistance of the salvaged RBCs was higher than that preoperatively. Furthermore, there were no tumour cells in the autologous salvaged RBCs. Conclusion: Our results showed no decrease in the quality of the autotransfused RBCs, urine was not retransfused; and there were no significant differences between the groups postoperatively. Although there were no tumour cells in the salvaged blood, the possibility of blood irradiation is discussed. We concluded that because of the risk of infection of homologous blood products, MAT is a safe possibility to reduce the amount of homologous blood transfusion required in connection with radical prostatectomy.
    Notes: Zusammenfassung Mit der intraoperativen maschinellen Autotransfusion (MAT) steht heute, neben anderen Möglichkeiten wie der präoperativen Eigenblutspende und der präoperativen normovolämischen Hämodilution, ein Verfahren zur Vermeidung von Fremdbluttransfusion zur Verfügung. Der Einsatz der MAT in der Tumorchirurgie sowie die Urinkontamination des OP-Situs zeigen die besonder Problematik der Qualitätssicherung des autologen Blutersatzes bei radikalen Prostatektomien. Neben möglichen Qualitätsveränderungen der retransfundierten Erythrozyten galt es, die Infektionsgefährdung, Gerinnungsveränderungen und eine mögliche Retransfusion von Tumorzellen zu untersuchen. Die Untersuchung wurde an insgesamt 24 Patienten der Urologischen Universitätsklinik Erlangen im Rahmen einer prospektiv randomisierten Studie durchgeführt. Anhand der Ergebnisse fand sich keine Qualitätsminderung der autotransfundierten Erythrozyten, Urin wurde nicht retransfundiert, und im postoperativen Verlauf konnten keine signifikanten Unterschiede zwischen den Vergleichsgruppen nachgewiesen werden. Tumorzellen im Cell-Saver-Erythrozytenkonzentrat (CS-EK) fanden sich nicht, eine Bestrahlung der CS-EK wird diskutiert. Gerade vor dem Hintergrund des bestehenden Infektionsrisikos homologer Blutprodukte sollte die MAT bei radikalen Prostatektomien als Möglichkeit zur Reduktion des Fremdblutbedarfs genutzt werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 1432-055X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Das abdominale Aortenaneurysma ist eine multifaktorelle Erkrankung, an dessen Enstehung genetische, biochemische, metabolische, mechanische und häodynamische Faktoren beteiligt sind [1, 2]. Die perioperative Klinikletalität rupturierter abdominaler Aneurysmen ist mit etwa 50 % in den vergangenen Jahrzehnten unverändert geblieben [3), während die perioperative Letalität bei elektivem infrarenalen Bauchaortenersatz von 20% in den 50er Jahren auf aktuell etwa 2–4 % gefallen ist [4]. Nur mit umfangreichen Kentnissen der anästhesiologischen Besonderheiten ist heute ein optimales perioperatives Management möglich. Die Arteriosklerose ist der häufigste ätiologische Risikofaktor, die koronare Herzkrankheit die häufigste Begleiterkrankung. Tabelle 1 gibt eine Übersicht der Inzidenz von Begleiterkrankungen bei Patienten mit rupturierten abdominalen Aortenaneurysmen: 85 % liegen infrarenal, Männer sind 5-mal häufiger betroffen als Frauen. Der Altersgipfel infrarenaler Aneurysmen liegt zwischen dem 60. Und 70. Lebensjahr.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1432-1807
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Mathematische Zeitschrift 42 (1937), S. 355-364 
    ISSN: 1432-1823
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Numerische Mathematik 1 (1959), S. 110-120 
    ISSN: 0945-3245
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mathematics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...