Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 113 (2000), S. 461-464 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: We have performed the fs pump–probe experiment on the B˜→a˜ nonadiabatic transition in the Hg–CO vdW complex. It is found that the transition occurs near the point where Hg and CO come nearest to each other on the B˜-state surface with a probability of 0.07 for their single encounter. This experiment serves as the first observation of the wave packet dynamics associated with an intermolecular energy flow in the vdW interaction. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 984-986 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Carbon–ion cancer treatment is successfully being made at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Design philosophy for the ion sources for medical facilities are as follows: (1) sufficient beam intensity, a few hundred e μA; (2) long lifetime with good stability; (3) easy operation and easy maintenance; and (4) compactness. In order to develop such source for future heavy-ion facilities, we have tested compact electron cyclotron resonance (ECR) ion sources using permanent magnets both for axial and radial confinement of hot electrons. Since the yield of C2+ ion in the first developed source (2.45 GHz ECR) was 15 e μA and far below the medical requirement (∼150 e μA for the HIMAC), a new source has been proposed, having a frequency of 10 GHz. The extracted intensity of C4+ (and C2+) ions is expected to be higher than 200 e μA. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1365-2109
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Experiments on induced spawning of the anostomid fish Leporinus elongatus Val. 1849, an important neotropical migratory fish, were carried out at Três Marias Fish Hatchery Station, State of Minas Gerais, Brazil, to develop a reliable protocol for inducing breeding in this species. L. elongatus matures reliably in earthen ponds to a point at which final maturation can be induced with carp pituitary extract. The following data were recorded: number of extruded eggs (g ova−1) = 2444 ± 740; stripped ova weight:body weight = 13.1 ± 2.9%; retained (ovulated but not stripped) ova weight:body weight = 5.8 ± 2.6%; initial fertility = 318.7 × 103± 149.2 × 103; final fertility = 229.3 × 103± 129.3 × 103; egg fertilization rate = 63.8 ± 16.4% and ≈ 229 000 larvae per female. The relationships between stripping time and water temperature and between hatching and water temperature were given by the same exponential equation t= ae–bT. The relationships between body weight (Wt) and initial (IF) and final fertility (FF) were expressed by the equations: IF =−9382 + 322 047 × Wt (r2= 0.84); FF =−40 780 + 265 062 × Wt (r2= 0.75).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Reproducible and quantitative evaluation of patient satisfaction with their complete dentures is of great importance for preoperative diagnosis, treatment planning and assessment of complete denture treatment outcome. This study attempted (1) to clarify the degree of contribution of various factors to overall satisfaction, and (2) to develop a method for quantitative assessment of overall satisfaction with complete dentures. Twelve satisfaction factors and a three-grade scale were used to assess 302 complete denture patients. The contribution of each grade of the 12 factors to the overall satisfaction level was determined by multiple regression analysis. Seven factors were highly correlated to the overall satisfaction. Based on the level of contribution by these seven significant factors, a scoring method for satisfaction was established. Category scores for these factors were calculated and the sum of the category scores was converted to an integer between 0 and 100. The resulting quantification score was closely correlated with overall satisfaction. A protocol for scoring overall satisfaction was developed based on the scientifically analysed contribution of each satisfaction factor.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: To gather knowledge related to establishing criteria for selecting soft denture liners for individual patients, the effects of certain properties of soft denture liners on stress distribution were evaluated by two-dimensional finite element analysis. A partial mandibular edentulous ridge crest was modelled. Six combinations of thickness (mucosa: 1 or 2 mm; soft denture liner: 1, 2, or 3 mm) and 18 combinations of Young's modulus (mucosa: three kinds; soft denture liner: six kinds) were analysed. The ratio of maximum to minimum stress in the mucosa (stress ratio) was calculated to estimate stress concentration. In the case of thin mucosa (1 mm thickness), the lower the Young's modulus of the soft denture liner, the lower the stress ratio. However, if the soft denture liner had a lower Young's modulus than the mucosa, stress concentrated adversely. These results suggest that the elasticity of the soft denture liner should match the elasticity of the mucosa to obtain the optimum cushioning effect.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: To prevent loosening or fracture of screws retaining the prosthesis to the implants in the posterior partially edentulous region, the use of staggered buccal and lingual offset placement or wide implants is suggested. However, it is not known how this usage compensates for the torque produced by lateral occlusal forces. This study evaluated the effectiveness of offset placement of three implants and a wide implant placement at the most posterior site. Three-dimensional geometric analysis was used to calculate the tensile force applied to gold screws in clinical situations with buccal or lingual loading perpendicular to cuspal inclination (10 or 20°). Four variations of the placement of three implants (∅ 3·75 mm) are: (1) straight; (2) buccal offset of the second implant; (3) lingual offset of the second implant; (4) a wide implant (∅ 5 mm) placement at most posterior site. The offset placement did not always decrease tensile force at the gold screw, but wide implant placement and decrease in cuspal inclination did.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: An I-bar clasp is a popular retainer for distal-extension removable partial dentures. However, there have been almost no evidence-based criteria on the mechanically preferable shape. The present study aimed to investigate the variations of dimension in I-bar clasps used in patients, and to clarify the effect of the variations on stiffness and stress of I-bar clasps by finite element analysis. Dimensions (thickness, width, taper, radius of curvature, length, relation to oral structures) of 23 I-bar clasps were measured. A three-dimensional finite element model was made for each measured I-bar clasp with vertical and horizontal straight sections connected with a curved section. A concentrated load of 5 N was applied at the lowest point of the tip that contacted the abutment in the buccal direction. Maximal equivalent stress and stiffness of each clasp were evaluated. The measured dimension, stiffness, and maximum stress showed wide variations. Mean stiffness was far from the proper one, and mean stress was near the proportional limit of Co–Cr alloy. Considering the stiffness and stresses in this study, only six clasps out of 23 were appropriate. These results suggest that evidence-based criteria of preferable shape of I-bar clasps should be determined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Double implants have been thought to have biomechanical advantages for single molar replacement. To evaluate the effectiveness of double implants versus a wide implant, the vertical forces and torque on each implant were calculated by three-dimensional geometric analysis. Buccal load (100 N) perpendicular to cuspal inclination (20°) was applied at the occlusal surface of the superstructure. The three kinds of load points (A, B, C) were 1·5, 3·5, and 5·5 mm from the mesial contact point, respectively. Three implants were compared: mesial and distal double implants (∅ 3·3 mm), and a wide implant (∅ 5 mm). The wide implant showed torque around the long axis (1·8–15·0 N · cm) whereas double implants had no torque. On the other hand, the vertical forces on the mesial double implant were both smaller (60%: loaded at point C) and larger (140%: loaded at point A) than the wide implant. Given the smaller surface area of the mesial double implant, this large force may generate much higher stress in the peri-implant bone. These results suggest that the biomechanical advantage of double implants for single molar replacement is questionable when the occlusal force is loaded at the occlusal surface near the contact point.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Scandinavian journal of medicine & science in sports 10 (2000), S. 0 
    ISSN: 1600-0838
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine , Sports Science
    Notes: In the present study, measurements of broadband ultrasound attenuation (BUA) were used as indications of bone quality in elderly residents of an old people’s home. To investigate the possibility of using number of steps walked as an indicator of the role played by exercise on bone quality, we studied the relationship between BUA and the number of steps, taken as a measure of the number of impacts against the ground placing a direct mechanical stress on the bones. The subjects were 59 healthy elderly women with a mean age of 78±8 years who had no impairments in walking or daily life. A statistical analysis of the relationship between age, number of steps, BUA, stride length, and walking speed revealed that number of steps and BUA declined with age, and that BUA increased with a greater number of steps. Among other factors, age was found to be negatively correlated with weight (r=−0.343, P〈0.01), BUA (r=−0.542, P〈0.001), total number of steps (r=−0.524, P〈0.001) and past exercise habits (r=−0.425, P〈0.001). There were positive correlations between BUA and total number of steps (r=0.606, P〈0.001), walking speed (r=0.460, P〈0.001), stride length (r=0.373, P〈0.01) and past exercise habits (r=0.429, P〈0.001). These results show that the benefit to bone quality increases the more a person walks in daily life. The above demonstrates that degree of walking activity is positively correlated to bone quality among the elderly. These results also suggest that, when investigating the relationship between exercise and bone quality, one should look not only at distance and walking speed, but also number of steps as the number of impacts against the ground that place a direct mechanical stress on the bones. This may prove to be a useful indicator of bone quality in future use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Journal of infection and chemotherapy 6 (2000), S. 173-177 
    ISSN: 1437-7780
    Keywords: Key wordsGardnerella vaginalis ; Vaginal microflora ; Healthy women ; Bacterial vaginosis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In order to find the vaginal prevalence of Gardnerella vaginalis in a normal female population, we determined the incidence of G. vaginalis in relation to that of other bacterial genera and species in the vagina. Two-hundred and thirty-nine healthy women were the subjects of this study. Vaginal discharge was collected and bacteriological studies were performed. The mean total aerobe count in the G. vaginalis-positive group was 9.02 log10 colony-forming units (CFU)/g, which was significantly higher (P 〈 0.0001) than that (6.80 log10 CFU/g) in the G. vaginalis-negative group. In contrast, there was no difference in the mean total anaerobe count between the two groups of subjects (8.82 and 8.24 log10 CFU/g, respectively in the case of including Lactobacillus species count). Also, the mean pH level of vaginal secretion in the G. vaginalis-positive group was 4.58, which was significantly higher (P 〈 0.005) than that (4.10) in the G. vaginalis-negative group. Aerobes were isolated at equal incidence in the two groups. Anaerobes were isolated at a significantly higher rate in the G. vaginalis-positive group (P 〈 0.005) than in the G. vaginalis-negative group. The mean count of Lactobacillus species was significantly higher (P 〈 0.0001) in the G. vaginalis-negative group than in the positive counterpart (7.02 vs 8.66). Elevation of vaginal pH, an increase in the anaerobe count, and decreases in the Lactobacillus species count could be good predictors of the prevalence of bacterial vaginosis in healthy women.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...