Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 2000-2004  (31)
  • 1985-1989  (39)
  • 1980-1984  (18)
  • 1
    Digitale Medien
    Digitale Medien
    s.l. : American Chemical Society
    The @journal of physical chemistry 〈Washington, DC〉 87 (1983), S. 4773-4776 
    Quelle: ACS Legacy Archives
    Thema: Chemie und Pharmazie , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 88 (2000), S. 3484-3489 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: We have prepared a sintered CoSb3–FeSb2 composite where the FeSb2 particles are dispersed in the CoSb3 matrix by mechanical grinding (MG) and hot pressing, and investigated the Seebeck coefficient, electrical resistivity, and thermal conductivity in order to estimate the corresponding figure of merit. The thermal conductivity of the composite is lower than that of CoSb3. The electrical resistivity of the composite increases with increasing MG time, but it is lower than that of CoSb3 at high temperature. The decrease in the thermal conductivity and the lesser increase in the electrical resistivity are ascribed to the enhancement of phonon scattering caused by the dispersion of FeSb2 particles in the CoSb3 matrix and the low electrical resistivity of FeSb2, respectively. As a result, the composite whose molar ratio of CoSb3 to FeSb2 is 0.7:0.3 and the MG time is 25 h has a maximum figure of merit value of 6.1×10−4 K−1 at 756 K. This value is much larger than the maximum value of CoSb3 at 482 K of 3.2×10−4 K−1. © 2000 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 92 (2002), S. 1391-1398 
    ISSN: 1089-7550
    Quelle: AIP Digital Archive
    Thema: Physik
    Notizen: (Zn1−yMgy)1−xAlxO powders were synthesized by the polymerized complex method and then consolidated by spark plasma sintering apparatus. The microscopic structure and thermoelectric properties were examined comparing with the experimental results of the samples prepared by the conventional solid-state reaction method. A small amount of ZnAl2O4 spinel phase as the second phase was observed in the sintered samples with x≥0.02 by x-ray diffraction and a scanning electron microscope. The grain size of the samples prepared by the polymerized complex method is much smaller than that of the samples prepared by the conventional solid-state reaction method. The absolute values of the Seebeck coefficient and electrical resistivity decrease with increasing x up to about x=0.01, but above x=0.01 they are almost independent of x. This result indicates that the solubility limit of Al in Zn1−xAlxO is about x=0.01, which is also confirmed by 27Al nuclear magnetic resonance spectroscopy. At a fixed composition of x, the absolute values of the Seebeck coefficient and electrical resistivity for the samples prepared by the polymerized complex method are smaller than those for the samples prepared by the solid-state reaction method, which indicates that the doping of the carrier into the material can be more easily realized in the samples prepared by the polymerized complex method. The thermal conductivity decreases with increasing x, but the further suppression of the thermal conductivity was attained by the additional substitution on the Zn site by Mg. The Seebeck coefficient of (Zn1−yMgy)1−xAlxO is almost independent of Mg content y, but the electrical resistivity increases with increasing y. As a result, (Zn0.90Mg0.10)0.9975Al0.0025O shows a maximum dimensionless figure of merit of 0.10 at 1073 K. © 2002 American Institute of Physics.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Science Ltd
    British journal of dermatology 144 (2001), S. 0 
    ISSN: 1365-2133
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Science Ltd
    British journal of dermatology 144 (2001), S. 0 
    ISSN: 1365-2133
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: We report a patient with paraneoplastic pemphigus associated with a thymic tumour. Immunoblot study using affinity-purified γ-catenin protein revealed that his serum recognized γ-catenin (plakoglobin) in epidermal, thymic tumour and mouse bladder extracts.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Oxford, UK : Blackwell Science Ltd
    British journal of dermatology 144 (2001), S. 0 
    ISSN: 1365-2133
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Medizin
    Notizen: Scrotal calcinosis has been classified as a form of idiopathic calcinosis cutis. However, the pathogenesis of the calcified nodules has not been fully elucidated: it is still unclear whether the condition is truly idiopathic, or the result of breakdown of calcified epithelial cysts. We describe a 29-year-old Japanese patient with scrotal calcinosis originating from epithelial cysts. Light microscopy revealed a large epithelial cyst containing von Kossa-positive material and several small dilated ductal structures beside the cyst. The epithelia of the cyst and ductal structures were connected, showing similar eccrine duct differentiation on immunohistochemical staining and electron microscopy. In the cyst lumen, calcium was present as needle-shaped crystals. The pathogenetic mechanism of calcium deposition seemed to be due to excessive production and discharge of matrical debris and sulphated mucopolysaccharides, which derived from luminal cells, and their accumulation in the lumina.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A high-resolution Compton spectrometer has been installed for 29.5-keV incident x rays from a vertical wiggler inserted in the 2.5-GeV storage ring of the Photon Factory at Tsukuba. This spectrometer consists of bent-crystal monochromator, a Cauchois-type bent-crystal analyzer, and an imaging plate as a position sensitive detector. The overall momentum resolution is 0.084 a.u. for the incident x-ray energy of 29.5 keV. High-resolution Compton profile measurements on Al, a quasicrystal Al-Li-Cu, and solid and liquid phase of Li are shown to demonstrate the performance of this spectrometer.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: Recent developments of the insertion devices have made it possible to utilize intense hard x rays for precise Compton-profile measurements. A Compton profile of Si (110), which is measured using 29.5-keV synchrotron-radiation x rays, is shown as an example of a precise measurement having a momentum resolution of 0.084 a.u., the best resolution ever achieved. A promising plan is presented on magnetic electron Compton-profile measurements using circularly polarized 60-keV x rays from a newly developed multipole wiggler in the 6-GeV accumulation ring at KEK as an elliptically polarized source.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 58 (1987), S. 932-938 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A new design concept of a streak tube is conceived to obtain femtosecond temporal resolution. It is based on four factors as follows. First, in order to decrease the photoelectron transit time spread, one must investigate how high electric field is practically usable near the photocathode. It is found that the value can be increased up to ∼6 kV/mm and this is used as a design value. Second, as the other method to decrease the photoelectron transit time spread, an electromagnetic focusing method must be adopted because there is no region similar to the focusing section of an electrostatic focusing type where the electric potential is low. Third, the focusing magnetic field should be located in a limited region to obtain a very high sweep speed of ∼2×108 m/s. And fourth, in the operation, a special readjustment of the focusing magnetic field should be performed to compensate the photoelectron beam defocusing caused by the very rapid transient deflection field. Based on the above, a new streak tube has been designed, manufactured, and tested. The limiting temporal resolution of ∼400 fs has been predicted theoretically and the value less than ∼500 fs has been experimentally produced.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 56 (1985), S. 2279-2282 
    ISSN: 1089-7623
    Quelle: AIP Digital Archive
    Thema: Physik , Elektrotechnik, Elektronik, Nachrichtentechnik
    Notizen: A time-resolvable Thomson-parabola spectrometer is developed employing a microchannel-plate image intensifier, which acts as a high-speed shutter (∼5 ns) by gating the applied voltage. Using such a spectrometer, we have achieved the measurement of temporal behavior of beam energy for various ion species of an intense pulsed ion beam extracted from a dual-current-feed magnetically insulated diode. The energy of protons is found to be in a good agreement with the diode voltage.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...