Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 4395-4408 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We describe a newly developed ultrahigh vacuum (UHV) experiment which combines molecular beam techniques and in situ surface spectroscopy. It has been specifically designed to study the reaction kinetics and dynamics on complex model catalysts. The UHV system contains: (a) a preparation compartment providing the experimental techniques which are required to prepare and characterize single-crystal based model catalysts such as ordered oxide surfaces or oxide supported metal particles; and (b) the actual scattering chamber, where up to three molecular beams can be crossed on the sample surface. Two beams are produced by newly developed differentially pumped sources based on multichannel arrays. The latter are capable of providing high intensity and purity beams and can be modulated by means of a vacuum-motor driven and computer-controlled chopper. The third beam is generated in a continuous or pulsed supersonic expansion and is modulated via a variable duty-cycle chopper. Angular and time-resolved measurements of desorbing and scattered molecules are performed with a rotatable doubly differentially pumped quadrupole mass spectrometer with a liquid-nitrogen cooled ionizer housing. Time-resolved but angle-integrated measurements are realized with a second nondifferentially pumped quadrupole mass spectrometer. In situ measurements of adsorbed species under reaction conditions are performed by means of an adapted vacuum Fourier transform infrared spectrometer. The spectrometer provides the possibility of time-resolved measurements and can be synchronized with any of the beam sources. This contribution provides a general overview of the system and a description of all new components and their interplay. We also present test data for all components employing simple adsorption/desorption and reaction systems. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 116 (2002), S. 762-773 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: In recent experiments, the rotational alignment of the laser induced nonthermal desorption of CO adsorbed on an epitaxially grown film of Cr2O3(0001) has been studied [Beauport, Al-Shamery, and Freund, Chem. Phys. Lett. 256, 641 (1996)]. At low-rotational quantum numbers J, the molecules desorb like helicopters (J-vector perpendicular to the surface) while at high J-values cartwheel motion is preferred (J-vector parallel to the surface). These stereodynamic effects and the experimental state resolved velocity distributions of the desorbing species are simulated by means of an exact time-dependent wave packet method in three dimensions. As a basis for this quantum-mechanical treatment of the CO desorption ab initio potential energy surfaces (PES) were used. The PES for the electronic ground state of the CO–Cr2O3(0001) system has been calculated previously by Pykavy et al. [Surf. Sci. 479, 11 (2001)] in an embedded cluster approach. As the intermediate state, generated by the laser irradiation, an internal CO excited state (5σ→2π*) was considered. The PES of this a 3Π-like state of CO adsorbed on Cr2O3(0001) was calculated at the ab initio CASSCF-level. Our key findings in the subsequent wave packet calculations are (1) a high-dimensional treatment of the photodesorption process is very important in this system, essentially the angular coordinates, very often neglected in similar studies, are responsible for a "successful" desorption event; (2) the change from the strongly tilted equilibrium geometry in the electronic ground state to the preferred upright position in the electronically excited state after laser irradiation is essential for the mechanistic picture of the desorption process; (3) the experimental phenomemon of rotational alignment can only be explained if the topologies of the PES of both the electronically excited and the ground state are accounted for; (4) the lifetime of the CO*-intermediate is in the order of 10 fs; (5) the molecule–surface vibrations in the electronic ground state do not much influence the asymptotic results at the experimental temperature of T=100 K. However, the inclusion of excited levels of the hindered rotation helps to gain insight into the desorption mechanism on a microscopic level. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1460-9568
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: To determine the cortical areas controlling memory-guided sequences of saccadic eye movements, we performed functional magnetic resonance imaging (fMRI) in six healthy adults. Subjects had to perform a memorized sequence of three saccades in darkness, after a triple-step stimulus of successively flashed laser targets. To assess the differential contribution of saccadic subfunctions, we applied several control conditions, such as central fixation with or without triple-step visual stimulation, self-paced saccades in darkness, visually guided saccades and single memory-guided saccades. Triple-step saccades strongly activated the regions of the frontal eye fields, the adjacent ventral premotor cortex, the supplementary eye fields, the anterior cingulate cortex and several posterior parietal foci in the superior parietal lobule, the precuneus, and the middle and posterior portion of the intraparietal sulcus, the probable location of the human parietal eye field. Comparison with the control conditions showed that the right intraparietal sulcus and parts of the frontal and supplementary eye fields are more involved in the execution of triple-step saccades than in the other saccade tasks. In accordance with evidence from clinical lesion studies, we propose that the supplementary eye field essentially controls the triggering of memorized saccadic sequences, whereas activation near the middle portion of the right intraparietal sulcus appears to reflect the necessary spatial computations, including the use of extraretinal information (efference copy) about a saccadic eye displacement for updating the spatial representation of the second or third target of the triple-step sequence.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1460-9568
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Functional magnetic resonance imaging (fMRI) was used to localize brain areas that were active during the observation of actions made by another individual. Object- and non-object-related actions made with different effectors (mouth, hand and foot) were presented. Observation of both object- and non-object-related actions determined a somatotopically organized activation of premotor cortex. The somatotopic pattern was similar to that of the classical motor cortex homunculus. During the observation of object-related actions, an activation, also somatotopically organized, was additionally found in the posterior parietal lobe. Thus, when individuals observe an action, an internal replica of that action is automatically generated in their premotor cortex. In the case of object-related actions, a further object-related analysis is performed in the parietal lobe, as if the subjects were indeed using those objects. These results bring the previous concept of an action observation/execution matching system (mirror system) into a broader perspective: this system is not restricted to the ventral premotor cortex, but involves several somatotopically organized motor circuits.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1572-879X
    Keywords: aluminum oxide ; hydroxyl groups ; rhodium ; growth ; scanning tunneling microscopy ; infrared spectroscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract In order to investigate how the presence of surface hydroxyl groups on oxide surfaces affects the interaction with the supported metal, we have modified a well-ordered alumina film on NiAl(110) by Al deposition and subsequent exposure to water. This procedure yields a hydroxylated alumina surface as revealed by infrared and high-resolution electron energy loss spectroscopy. By means of scanning tunneling microscopy, we have studied the growth of rhodium on the modified film at 300 K. Clear differences in the particle distribution and density are observed in comparison to the clean substrate. While, in the latter case, decoration of domain boundaries as typical defects of the oxide film governs the growth mode, a more isotropic island distribution and a drastically increased particle density is found on the hydroxylated surface. From infrared data, it can be deduced that the growth is connected with the consumption of the hydroxyl groups due to the interaction between the metal deposit and the hydroxylated areas. This finding is in line with photoemission results published earlier.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1432-1920
    Keywords: Key words Magnetic resonance imaging, diffusion-weighted ; Magnetic resonance imaging, perfusion ; Stroke, acute
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report acute and follow-up diffusion- and perfusion-weighted MRI (DWI, PWI) findings in a patient with a prolonged reversible ischaemic neurological deficit. PWI 12 h after the patient was last seen to be without symptoms revealed a large perfusion deficit in the left posterior MCA territory with a relatively inconspicuous and much smaller abnormality on DWI. Follow-up showed resolution of abnormalities on both DWI and PWI, and conventional MRI was normal, apart from a very slight abnormality, visible only on FLAIR images, at the centre of the initially DWI-positive region. These findings demonstrate the utility of PWI when be used in combination with DWI to investigate the pathophysiology of transient ischemic syndromes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...