Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 90 (2001), S. 1545-1549 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Two desorption peaks of hydrogen molecule (mass number=2), starting at about 600 and 950 K, respectively, are observed in thermal desorption mass spectroscopy of nanostructured graphite mechanically milled for 80 h under hydrogen atmosphere. It follows from a combined analysis of thermal desorption mass spectroscopy and thermogravimetry, that ∼6 mass % of hydrogen (corresponding to 80% of the total amount of hydrogen) is desorbed at the first desorption peak as a mixture of pure hydrogen and hydrocarbons. Below the temperature of the second desorption peak, at which recrystallization related desorption occurs, nanostructured graphite is expected to retain its specific defective structures mainly with carbon dangling bonds as suitable trapping sites for hydrogen storage. The formation process of the nanostructures during milling under hydrogen atmosphere is also discussed on the basis of the profile of Raman spectroscopy. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Histopathology 37 (2000), S. 0 
    ISSN: 1365-2559
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this study, which made use of visual biofeedback, was to determine how methods of regulating jaw tapping force differed depending on the strength of the tapping, using the force curve as an index. Nine healthy examinees were asked to make 30–35 jaw tapping movements, reproducing the defined target tapping force as accurately as possible. We measured the duration of the tooth contact phase, the time to peak force, the first time derivative of force (peak dF/dt), and the time to peak dF/dt. The results indicated that the duration of the tooth contact phase and the time to peak force increased with the target value (P 〈 0·01). As the target rose, the peak dF/dt increased significantly (P 〈 0·01), but the time to peak dF/dt was not significant (P=0·134). We found that the higher the target value, the greater the degree of dependency on feedback information. We also found that both the peak dF/dt and the time to peak dF/dt were determined for each examinee prior to movement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 31 (2004), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  Heatless Glass® (HG) was applied to the basal surface of dentures as a coating material. To evaluate the influence of this material on the retentive force of the dentures, the adhesive force of pairs of resin specimens (heat curing resin), metal specimens (Co–Cr alloy), and HG metal specimens (Co–Cr alloy coated with HG), using tap water or resting saliva as a medium was measured, and the following results were obtained. (i) The adhesive force of metal specimens coated with HG material was significantly larger (by 2·3–2·6 times) than that of resin materials (P 〈 0·001), and it was slightly lower (0·8–0·9 times) than that of metal specimens, showing no significant difference (P 〉 0·10). (ii) The adhesive force of specimens using tap water as a medium was approximately one-half to two-third of that of specimens using resting saliva as a medium. (iii) When resting saliva was used as the medium, the maximum difference in the adhesive force of the specimens among subjects was 1·7 times. (iv) These findings suggested that, from the perspective of adhesive force, HG coating material is suitable for application to the basal surface of dentures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 27 (2000), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this study, which made use of visual biofeedback, was to determine whether jaw tapping force reproduction is related to the strength of tapping and to investigate how jaw tapping force affects the tapping movement curve. Nine healthy examinees were asked to reproduce jaw tapping force. We found that the ease and method of regulating jaw tapping force differed depending on the target force. We also found that jaw tapping force was regulated by alteration of the jaw opening distance, the duration of the tooth contact phase, the duration of the jaw closing phase, the maximum jaw opening velocity, and the maximum jaw closing velocity. However, the duration of the jaw opening phase and cycle time was not affected by force regulation under our experimental conditions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Titanium (Ti) is thought to be a highly biocompatible material, and its clinical applications are becoming increasingly frequent. However, there have recently been some clinical papers reporting hypersensitivity and allergic reactions to Ti. The purpose of this study was to assess the corrosive properties of Ti in the intra-oral environment in vitro. Cast pure Ti specimens were immersed in artificial saliva, physiological saline solution, and 128 mmol L−1 of lactic, formic and acetic acids for 3 weeks at 37 °C with shaking. The colour, weight, surface morphologies and chemical binding state of specimens were observed before and after immersion. Marked discoloration was recognized on the surface of specimens immersed in formic acid, and a significant difference was found between the immersion solutions. Weight changes also varied with solutions; a tendency to increase in formic acid and to decrease in lactic acid. A slight loss was observed in specimens immersed in lactic acid and artificial saliva. The oxide layer composed mainly of Ti-oxide on the surface of the immersed specimens was thinnest in lactic acid, and thickest in formic acid. The present study indicates that both hydrogen evolution type and oxygen diffusion type corrosion on Ti surfaces are possible in the living body. (Our results also confirm some clinical studies reporting Ti accumulation in surrounding tissues and Ti causing allergic reactions.)
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The influence of mechanical stimulation on the human body is extremely important. We hypothesized that if tooth impact is propagated to other sites of the body, this impact will have some effect on those sites as well. The purpose of this study was to investigate the extent to which tooth impact was propagated in the head and neck. It was found that the waves recorded on the upper canine are divided into a high frequency component and a low frequency component at a border of approximately 7 kHz. The amplitude of the impulse wave was 80·813 g for the low frequency component, and 177·839 g for the high frequency component. In terms of propagated vibration from the canine, the amplitude of the low frequency component was larger than that of the high frequency component, and greatest at the chin, followed in descending order by the zygomatic bone, forehead and vertebra prominens. For both frequency components, the amplitude of the propagated vibrations was small compared with the impulse waves. These results provide a basis for future analysis of the influence of such impact on cell response.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  The characteristics of head movement during voluntary rapid jaw opening movement and passive jaw depression were investigated using accelerometers and electromyographs (EMG) on eight healthy examinees. Passive depressions were executed by means of load on the lower jaw, initiated either by examinees themselves or an experimenter. In the depression initiated by examinees, a head-extension movement that preceded the load to the lower jaw and anticipatory activities in the nuchal region of the trapezius muscle were observed. In the depression initiated by the experimenter, the anticipatory activities were not observed. In both of these cases, stretch reflexes were induced in the trapezius muscle. During voluntary rapid jaw opening, a head-extension movement nearly synchronized with the opening movement in the lower jaw acceleration, and dorsal-neck muscle activities accompanying the synchronized movement were observed. The peak timing of these neck-muscle activities preceded the latencies of the stretch–reflex activities observed in the jaw-depressed tasks, but no anticipatory activities were observed in the dorsal-neck muscles. We conclude that neither the anticipatory activities nor the reflex activities observed in the passive depressions have effects on the initial part of the dorsal-neck muscle activities, which are related to the head-extension synchronized with the voluntary lower-jaw opening movement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this study was to determine whether the start of the synchronized head movement during mandibular movement is evoked by the peripheral reflexes following mandibular movement (i.e. stretch or trigemino-neck reflexes), or, alternatively, is started by pre-programmed central command. Head movement accompanying voluntary rapid jaw opening movement was studied using accelerometers fixed to the upper and lower incisors, as well as electromyographs (EMGs) of the neck muscles. The direction of head acceleration at the upper incisor was towards head extension at the beginning of jaw opening movement in 89·2% of all trials, opposite to the direction of lower jaw acceleration. The onset of head acceleration was later than that of the lower jaw acceleration by averages of 6·2–10·7 ms, and the onset of electromyographic activities of the sternocleidomastoid (SCM) muscle preceded that of head acceleration by an average of 12·5–24·3 ms. These findings suggest that head movement during mandibular movement is not started by peripheral reflexes but by pre-programmed central commands. This may be relevant to muscular discomfort in the neck and shoulder regions of patients with stomatognathic disorders.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 80 (2002), S. 318-320 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Nanostructured h-BN was prepared by mechanical milling under hydrogen atmosphere. The hydrogen concentration reaches up to 2.6 mass% after milling for 80 h, and this value corresponds to ca. 35% of that of nanostructured graphite as was previously reported. In addition to the hydrogen desorption starting at about 570 K, nitrogen desorption was also detected at about 700 K. There was no recrystallization phenomenon at least below 1173 K. The dissimilarities on the (de-)hydriding properties between nanostructured h-BN and graphite might be due to the different local electronic structure near the specific defects. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...