Library

Language
Preferred search index
Number of Hits per Page
Default Sort Criterion
Default Sort Ordering
Size of Search History
Default Email Address
Default Export Format
Default Export Encoding
Facet list arrangement
Maximum number of values per filter
Auto Completion
Feed Format
Maximum Number of Items per Feed
feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 90 (2001), S. 1545-1549 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Two desorption peaks of hydrogen molecule (mass number=2), starting at about 600 and 950 K, respectively, are observed in thermal desorption mass spectroscopy of nanostructured graphite mechanically milled for 80 h under hydrogen atmosphere. It follows from a combined analysis of thermal desorption mass spectroscopy and thermogravimetry, that ∼6 mass % of hydrogen (corresponding to 80% of the total amount of hydrogen) is desorbed at the first desorption peak as a mixture of pure hydrogen and hydrocarbons. Below the temperature of the second desorption peak, at which recrystallization related desorption occurs, nanostructured graphite is expected to retain its specific defective structures mainly with carbon dangling bonds as suitable trapping sites for hydrogen storage. The formation process of the nanostructures during milling under hydrogen atmosphere is also discussed on the basis of the profile of Raman spectroscopy. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1365-2133
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A 73-year-old man with angiosarcoma of the scalp died about 1 year after disease onset, despite systemic and topical administration of recombinant interleukin-2. Histopathology showed typical changes of endothelial cells with very sparse lymphocytic infiltration into the tumour. An autopsy revealed that the primary site penetrated cranial bone and invaded vertically into the subarachnoid space. Multiple metastases to lung, chest wall, vertebrae and ribs were also found. On immunofluorescence staining, the expression of vascular endothelial cadherin, which is present in normal endothelium, was absent from both primary and metastatic sites. This may have promoted local invasion and metastasis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 81 (2002), S. 1047-1049 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The letter reports the fabrication of MgB2 superconducting tape using a flexible metallic substrate as well as its strong pinning force, which was verified by direct measurement of transport critical current density. The tape was prepared by depositing MgB2 film on a Hastelloy tape buffered with an yttria-stabilized-zirconia layer. The Jc of the tape exceeds 105 A/cm2 at 4.2 K and 10 T, which is considered as a common benchmark for magnet application. The Jc dependence on magnetic field remains surprisingly very small up to 10 T, suggesting that the tape has much better magnetic field characteristic than conventional Nb–Ti wires in liquid helium. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 80 (2002), S. 318-320 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Nanostructured h-BN was prepared by mechanical milling under hydrogen atmosphere. The hydrogen concentration reaches up to 2.6 mass% after milling for 80 h, and this value corresponds to ca. 35% of that of nanostructured graphite as was previously reported. In addition to the hydrogen desorption starting at about 570 K, nitrogen desorption was also detected at about 700 K. There was no recrystallization phenomenon at least below 1173 K. The dissimilarities on the (de-)hydriding properties between nanostructured h-BN and graphite might be due to the different local electronic structure near the specific defects. © 2002 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 78 (2001), S. 2914-2916 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: High-density bulk materials of a recently discovered 40 K intermetallic MgB2 superconductor were prepared by high-pressure sintering. Superconducting transition with the onset temperature of 39 K was confirmed by both magnetic and resistive measurements. Magnetization versus field (M–H) curve shows the behavior of a typical type-II superconductor and the lower critical field Hc1(0) estimated from the M–H curve is 0.032 T. The bulk sample shows good connection between grains and critical current density Jc estimated from the magnetization hysteresis using sample size was 5×104 A/cm2 at 20 K and 1 T. Upper critical field Hc2(0) determined by extrapolating the onset of resistive transition and assuming a dirty limit is 18 T. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 79 (2001), S. 2435-2437 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: MgB2 tapes and wires were fabricated by the powder-in-tube method. Stainless steel and Cu–Ni tubes were used as sheath materials, and no heat treatment was applied. The tapes made of stainless steel showed transport critical current density Jc of about 10 000 A/cm2 at 4.2 K and 5 T. A high Jc of about 300 000 A/cm2 was obtained by extrapolating the Jc–B curves to zero field. Multifilamentary (seven-core) MgB2 wire was successfully fabricated using Cu–Ni tubes. For both tapes and wires, the grain connectivity of MgB2 was as good as a high-pressure sintered bulk sample. However, the Jc of the Cu–Ni sheathed wire was lower than the stainless steel sheathed tape due to the lower packing density of MgB2. © 2001 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this study was to determine whether the start of the synchronized head movement during mandibular movement is evoked by the peripheral reflexes following mandibular movement (i.e. stretch or trigemino-neck reflexes), or, alternatively, is started by pre-programmed central command. Head movement accompanying voluntary rapid jaw opening movement was studied using accelerometers fixed to the upper and lower incisors, as well as electromyographs (EMGs) of the neck muscles. The direction of head acceleration at the upper incisor was towards head extension at the beginning of jaw opening movement in 89·2% of all trials, opposite to the direction of lower jaw acceleration. The onset of head acceleration was later than that of the lower jaw acceleration by averages of 6·2–10·7 ms, and the onset of electromyographic activities of the sternocleidomastoid (SCM) muscle preceded that of head acceleration by an average of 12·5–24·3 ms. These findings suggest that head movement during mandibular movement is not started by peripheral reflexes but by pre-programmed central commands. This may be relevant to muscular discomfort in the neck and shoulder regions of patients with stomatognathic disorders.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The purpose of this study, which made use of visual biofeedback, was to determine how methods of regulating jaw tapping force differed depending on the strength of the tapping, using the force curve as an index. Nine healthy examinees were asked to make 30–35 jaw tapping movements, reproducing the defined target tapping force as accurately as possible. We measured the duration of the tooth contact phase, the time to peak force, the first time derivative of force (peak dF/dt), and the time to peak dF/dt. The results indicated that the duration of the tooth contact phase and the time to peak force increased with the target value (P 〈 0·01). As the target rose, the peak dF/dt increased significantly (P 〈 0·01), but the time to peak dF/dt was not significant (P=0·134). We found that the higher the target value, the greater the degree of dependency on feedback information. We also found that both the peak dF/dt and the time to peak dF/dt were determined for each examinee prior to movement.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford UK : Blackwell Science Ltd
    Journal of oral rehabilitation 28 (2001), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The influence of mechanical stimulation on the human body is extremely important. We hypothesized that if tooth impact is propagated to other sites of the body, this impact will have some effect on those sites as well. The purpose of this study was to investigate the extent to which tooth impact was propagated in the head and neck. It was found that the waves recorded on the upper canine are divided into a high frequency component and a low frequency component at a border of approximately 7 kHz. The amplitude of the impulse wave was 80·813 g for the low frequency component, and 177·839 g for the high frequency component. In terms of propagated vibration from the canine, the amplitude of the low frequency component was larger than that of the high frequency component, and greatest at the chin, followed in descending order by the zygomatic bone, forehead and vertebra prominens. For both frequency components, the amplitude of the propagated vibrations was small compared with the impulse waves. These results provide a basis for future analysis of the influence of such impact on cell response.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 31 (2004), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary  Heatless Glass® (HG) was applied to the basal surface of dentures as a coating material. To evaluate the influence of this material on the retentive force of the dentures, the adhesive force of pairs of resin specimens (heat curing resin), metal specimens (Co–Cr alloy), and HG metal specimens (Co–Cr alloy coated with HG), using tap water or resting saliva as a medium was measured, and the following results were obtained. (i) The adhesive force of metal specimens coated with HG material was significantly larger (by 2·3–2·6 times) than that of resin materials (P 〈 0·001), and it was slightly lower (0·8–0·9 times) than that of metal specimens, showing no significant difference (P 〉 0·10). (ii) The adhesive force of specimens using tap water as a medium was approximately one-half to two-third of that of specimens using resting saliva as a medium. (iii) When resting saliva was used as the medium, the maximum difference in the adhesive force of the specimens among subjects was 1·7 times. (iv) These findings suggested that, from the perspective of adhesive force, HG coating material is suitable for application to the basal surface of dentures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...