Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 2000-2004  (2)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 987-989 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Two electron cyclotron resonance (ECR) ion sources were manufactured for the accelerator facility at the Hyogo Ion Beam Medical Center. H2+, He2+, and C4+ were chosen as the accelerating ions because they have the highest charge to mass ratio among ion states which satisfy the required intensity and quality. The sources have the same structure as the 10 GHz ECR source at the Heavy Ion Medical Accelerator in Chiba except for a few improvements in the magnetic structure. Their performance was investigated at the Sumitomo Heavy Industries factory before shipment. The maximum intensity was 1500 μA for H2+, 1320 μA for He2+, and 580 μA for C4+ at the end of the ion source beam transport line. These are several times higher than required. Sufficient performance was also observed in the flatness and long-term stability of the pulsed beams. These test results satisfy the requirements for medical use. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Ltd
    Journal of oral rehabilitation 31 (2004), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: summary   The object of this study was to determine the best inclination of the intra-oral tracing device to get optimum condylar position with the registration of tapping movement. Three appliances with different tracing plate inclinations were used in five healthy subjects. The tracing plates were set at 0° to occlusal plane (horizontal); at the angle formed by drawing a line from condylar point to the stylus position at occlusal plane (inclined); then at the angle half to inclined (half-inclined). Subjects made Gothic arch and tapping movements (n = 30) at a 30 mm interincisal distance with the head Camper plane horizontal. The incisal and condylar points were tracked with a 6-degree-of-freedom jaw movement tracking system. The location of gothic arch apex, the distribution and mean position of 30 tapping points from intercuspal position were analyzed in incisal and condylar point between the appliances. Data were analyzed with repeated measures one-way anova. Results showed that mean position of tapping points were significantly different among the appliances. Half-inclined appliance recorded tapping points in a convergent area nearer to intercuspal position (IP) than other appliances. In all appliances, the contact points of the tapping movement were anterior to Gothic arch apex.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...