Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 1365-3059
    Quelle: Blackwell Publishing Journal Backfiles 1879-2005
    Thema: Land- und Forstwirtschaft, Gartenbau, Fischereiwirtschaft, Hauswirtschaft
    Notizen: Laboratory and glasshouse experiments demonstrated that priming of carrot seeds infected with Alternaria dauci did not affect the rate of transmission of the pathogen. Iprodione applied as a dust to unprimed, infected seeds at 5 ga.i. per kg seed effectively reduced disease transmission. Iprodione (0.1% a.i.) or thiram (0.1% a.i.) added in polyethylene glycol (PEG; filter paper or bubble-column priming systems) only partially reduced infection. Further dusting of the primed and dried seeds with iprodione, or alternatively application of that fungicide in a polymer film coat as the final stage in the process engineering of carrot seeds, was necessary to achieve complete control. The addition of thiram in the priming fluid, followed by an application of iprodione to the primed and dried seeds, improved the emergence and yield of carrots in the field.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Bioprocess engineering 18 (1997), S. 7-16 
    ISSN: 0178-515X
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract The morphology of filamentous organisms in submerged cultures varies between the pelleted and the dispersed forms depending on the strain of organism and the culture conditions. The dispersed form consists of branched and unbranched hyphae (freely dispersed form) and clumps (filamentous material in aggregates). In agitated systems, the choice of impeller geometry as well as the total power input determines the mechanical forces that might affect the morphology of filamentous species (e.g. by fragmentation) with simultaneous effects on their growth and productivity. To find out more about fragmentation of Penicillium chrysogenum caused by mechanical forces of different impeller types and agitation intensities, a population balance model has been developed. The projected area measured by image analysis was used to characterise the morphology (size) of the mycelia. In the model, the kinetics of mycelial fragmentation were expressed by a breakage rate constant K, which was assumed to be only dependent on the agitation conditions. The fragmentation rate was considered to follow a first order process in size (area) which was based on assumptions made for the mechanism of mycelial break-up, and work reported in the literature. Previously published mean and distributional data from off-line fragmentation experiments in ungassed vessels of sizes from 1.4 to 180 l were used to validate the model. For the first time a model has been found that is capable of fitting changes in mycelial morphology caused by mechanical forces generated by different impellers at various power inputs and scales. Besides the mean projected areas of the mycelia, the model allowed simulations of the projected area distributions, and changes in those distributions because of the agitation. At the small scale (1.4 l), the breakage rate constant K could be correlated well with either impeller tip speed or the “energy dissipation/circulation function”, which is based on mycelial circulation through the impeller region. The simpler but commonly used power input per unit tank volume did not correlate K adequately. The scale up data showed that only the “energy dissipation/circulation function” correlated mycelial fragmentation well. The dependence of K on biomass concentration, and its detailed dependence (if any) on the fermentation conditions at sampling, which might indicate likely breakage mechanisms, remain to be elucidated.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 1432-0797
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Abstract Viscoelasticity has important implications in mass transfer and mixing processes. Previous studies regarding to the viscoelastic behaviour of xanthan solutions have been carried out with diluted solutions or they have not covered a wide range of polymer concentrations. In this study, it was shown that the first normal stress difference measured in fermentation broths is highly dependent on shear rate, and this viscoelastic level is modified by the heat treatment to which the broths are subjected as a postfermentative procedure. The viscoelasticity level is different for xanthan solutions prepared with products arising from different sources and for fermentation broths before the heat treatment, if compared with that measured in end-products. In general, the higher the polymer concentration, the higher the viscoelasticity (expressed as first normal stress difference or Weissenberg number). The addition of a biocide, the change in ionic strength and the addition of sucrose to the xanthan solutions, lead to significant changes in the first normal stress difference.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 52 (1996), S. 672-684 
    ISSN: 0006-3592
    Schlagwort(e): mycelial morphology ; Penicillium chrysogenum ; image analysis ; impeller geometry ; energy dissipation rate ; circulation frequency ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: The influence of the agitation conditions on the morphology of Penicillium chrysogenum (freely dispersed and aggregated forms) was examined using radial (Rushton turbines and paddles), axial (pitched blades, propeller, and Prochem Maxflow T), and counterflow impellers (Intermig). Culture broth was taken from a continuous fermentation at steady state and was agitated for 30 min in an ungassed vessel of 1.4-L working volume. The power inputs per unit volume of liquid in the tank, P/VL, ranged from 0.6 to 6 kW/m3. Image analysis was used to measure mycelial morphology. To characterize the intensity of the damage caused by different impellers, the mean total hyphal length (freely dispersed form) and the mean projected area (all dispersed types, i.e., also including aggregates) were used. [In this study, breakage of aggregates was taken into account quantitatively for the first time.]At 1.4-L scale and a given P/VL, changes in the morphology depended significantly on the impeller geometry. However, the morphological data (obtained with different geometries and various P/VL) could be correlated on the basis of equal tip speed and two other, less simple, mixing parameters. One is based on the specific energy dissipation rate in the impeller region, which is simply related to P/VL and particular impeller geometrical parameters. The other which is developed in this study is based on a combination of the specific energy dissipation rate in the impeller swept volume and the frequency of mycelial circulation through that volume. For convenience, the function arising from this concept is called the “energy dissipation/circulation” function.To test the broader validity of these correlations, scale-up experiments were carried out in mixing tanks of 1.4, 20, and 180 L using a Rushton turbine and broth from a fed-batch fermentation. The energy dissipation/circulation function was a reasonable correlating parameter for hyphal damage over this range of scales, whereas tip speed, P/VL, and specific energy dissipation rate in the impeller region were poor. Two forms of the energy dissipation/circulation function were considered, one of which additionally allowed for the numbers of vortices behind the blades of each impeller type. Although both forms were successful at correlating the data for the standard impeller designs considered here, there was preliminary evidence that allowing for the vortices would be valuable. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 49 (1996), S. 15-19 
    ISSN: 0006-3592
    Schlagwort(e): viscous fluid ; fluid dynamic study ; Xanthan solution ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Studies were conducted1 in 19-m3 fermentors (14-m3 working volume) using four Rushton turbines, four Prochem Maxflo Ts, and three Lightnin' A315s and the results in water have been reported earlier. Here, a 1.7 wt/vol% Xanthan solution has been used as the working fluid, simulating viscous broths to give Reynolds numbers (Re) between 1800 and 4500. As predicted from small-scale studies, the power numbers at these values of Re were similar to those in water. The K factor (the ratio of power draw under aerated conditions compared to non-aerated) was the same as in water at the higher values of Re, but at the lower values it fell more rapidly with increasing aeration rate and to a lower value than in water. At all times, K was higher than with Rushton turbines. Vibration characteristics were also measured. Under aerated conditions, the fermentors vibrated with an amplitude 75% to 100% less than in water due to viscous damping. With increasing air flow, the amplitude increased steadily due to the presence of very large and rapidly rising bubbles in such fluids to give values 2.5 to 3 times those in water. Nevertheless, these mechanical problems can be overcome, allowing such agitators to be used successfully in high viscosity mycelial fermentations. © 1996 John Wiley & Sons, Inc.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 41 (1995), S. 741-742 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 40 (1994), S. 1940-1949 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Studies on the dynamics of phase inversion available offer limited information due to the difficulty of following the transient mean and drop-size distribution. A new technique developed provides such data. A stereo microscope with a very shallow depth of field attached to a video camera gives sharp images of droplets in intensely-agitated, immiscible liquid dispersions by using a Strobotach pulsing at the camera framing rate. Droplets from 40 μm upward at concentrations up to 70% by volume dispersed phase can be measured accurately. Droplets of continuous organic phase in aqueous drops can be seen. The pictures can be analyzed semiautomatically using a computer and in-house software to give, using a variety of discretizations, cumulative and frequency distributions to any base and any mean size. Means and distributions are a function of time for phase inversions generated in three ways. The technique gives a powerful tool for understanding fast, complex dispersion processes.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 44 (1994), S. 1177-1185 
    ISSN: 0006-3592
    Schlagwort(e): bioreactor retrofitting ; hydrofoils ; fermentor ; large ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Studies were conducted in three 19-m3 fermentors (14 m3 working volume, aspect ratio = 3:1), one fitted with four Rushton turbines (D/T = 0.35), one with three Lightnin' A315 hydrofoil impellers (D/T = 0.46). The power drawn under the same aerated conditions relative to the unaerated ones was always greater with the hydrofoils, which gives them the potential for enhanced mass transfer rates under practical operating conditions. However, the power draw was also sensitive to the magnitude of the unaerated power. Indeed, at low unaerated specific power (∼0.6 W-kg) and high air flow rates (∼1vvm), the relative power draw with the hydrofoils could be even greater than 1. The hold-up with each of the impellers was broadly similar at the same aeration rate and power input, though the later had a much smaller impact in these large vessels than has been reported in the literature based on smaller scale work. As usual, repressed coalescence caused increased hold-up, and, with the hydrofoils, this increase was associated with a lower power draw. Because of the greater mechanical vibration of the reactors with the hydrofoils, vibration characteristics of the vessels were measured and they were very similar. The results showed that provided care is taken in the mechanical design of the system, such impellers can operate reliably in large-scale fermentations with the potential for enhanced biological performance. © 1994 John Wiley & Sons, Inc.
    Zusätzliches Material: 15 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    ISSN: 1573-6776
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Summary Insect cells have been propagated in monolayers in T-flasks or in suspension culture in spinner flasks, the latter being conducted over a range of spinner speeds. In both configurations, the cells were also infected with either wild or recombinant β-galactosidase baculovirus at MOI of 0.1, 1 and 10. The strength of both uninfected and infected cells was also measured by a micro-manipulation technique. No significant difference in growth rate was obtained between monolayer culture and suspension culture at the spinner rate which was optimum for growth. This optimum was quite sharp. At the lowest speeds cells settled, whilst above the optimum speed the spinner action led to significant cell damage. The maximum infectivity was obtained at this optimum speed which also gave maximum survival after infection. There were significant changes of cell survival and infection, even over relatively small changes of speed, and presumably energy dissipation rate. As changes in growth in turbine-agitated bioreactors have been shown to be much less, even when the energy inputs varied by two orders of magnitude, these findings throw doubt on the usefulness of spinner flasks for assessing “shear” sensitivity of cell lines. The percentage of infected cells and β-galactosidase production were significantly lower in the monolayer culture compared to that in the suspension culture at MOI values below 10 pfu/cell. This difference is explained as being due to the reduced movement of released virus particles from infected to non-infected cells in the T-flasks.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 10
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 57 (1998), S. 95-108 
    ISSN: 0006-3592
    Schlagwort(e): Xanthan fermentation ; impeller type ; power consumption ; mixing ; oxygen transfer ; Xanthan productivity ; product quality ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: The rheological complexity of Xanthan fermentations presents an interesting problem from a mixing viewpoint, because the phenomena of poor bulk blending and low oxygen mass transfer rates inherent in highly viscous fermentations (and their consequences) can be systematically investigated, even at the pilot plant scale. This study in a 150 L fermentor compares the physical and biological performance of four pairs of impellers: a standard Rushton turbine, a large diameter Rushton turbine, a Prochem Maxflo T, and a Scaba 6SRGT. Accurate in-fermentor power measurements, essential for the comparison of impellers in relation to operating costs are also reported. It is demonstrated that the agitator performance in Xanthan fermentations is very specific and the choice of which impeller to use in bioreactors to obtain enhanced performance is dependant on the applied criterion. None of the criterion favored the use of the standard Rushton turbine, therefore suggesting that there are strong grounds for retrofitting these impellers with either large diameter impellers of similar design or with novel agitators. In addition, fluid dynamic modeling of cavern formation has clearly highlighted the importance of a well mixed and oxygenated region for providing the capacity for high microbial oxygen uptake rates which govern Xanthan productivity and quality. © 1998 John Wiley & Sons, Inc. Biotechnol Bioeng 57: 95-108, 1998.
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...