    Haemophilia 5 (1999), S. 0 
    ISSN: 1365-2516
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Acquired haemophilia is a rare disorder requiring therapy to control bleeding and to suppress the inhibitory antibody. High-dose intravenous immunoglobulin is commonly used as part of immunosuppressive regimens for this condition. We describe the case of an elderly patient who developed acute oliguric renal failure as a result of intravenous immunoglobulin therapy. All patients receiving such treatment should have renal function carefully monitored both during and after the infusion.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-4838
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract The development and utilization of a parallel plate flow system to study the blood response to flat sheet biomaterials, is described. Unlike most other parallel plate flow systems, which have been used to study cellular interactions with biomaterials, the controlled flow test cell described below employs the test materials on both sides of the channel through which the blood flows. The flow cell is used to conduct an investigation into the in vitro generation of C3a by a regenerated cellulose membrane, Cuprophan. The effects of experimental variables such as temperature, blood flow rate, contact area and wall shear rate on C3a generation by Cuprophan were studied. The results show that C3a generation by Cuprophan is lower at 12 °C than at 22 °C, which is in turn lower than C3a generation at 37 °C. Furthermore, a decrease in contact area, and increase in wall shear rate and blood flow rate, can produce a decrease in C3a concentration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1573-4838
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine , Technology
    Notes: Abstract An investigation has been made of blood interactions with plasticized poly(vinyl chloride) (PVC) biomaterials in tubular form, taking into account the influence on the blood response of the polymer, antithrombotic agent, blood condition and test procedure. In vitro and ex vivo procedures were used to achieve a comparison between PVC plasticized with di- (2-ethylhexyl)phthalate (DEHP) and with tri-(2-ethylhexyl)trimellitate (TEHTM). The blood response was monitored in terms of the measurement of fibrinogen adsorption capacity, thrombin–antithrombin III complex (TAT) and the complement component C3a. Surface characterization of the polymers was performed by X-ray photoelectron spectroscopy (XPS). The data obtained indicate that in comparison with DEHP-PVC, there is a higher reactivity for TEHTM-PVC, which correlates with the plasticizer distribution at the polymer surface. © 1999 Kluwer Academic Publishers
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We investigated hemodialysis membrane biocompatibility with respect to contact phase activation by determination of FXII-like activity (FXIIA) on the membrane surface and in the supernatant phase, during plasma contact with various hemodialysis membranes using an in vitro incubation test cell. The results were compared to the influence of these membranes on the activation of purified FXII. A time course for the generation of activated FXII using purified FXII solution at physiologic concentrations on two similar negatively charged polymers was performed. The membranes assessed were regenerated cellulose (Cuprophan; Akzo Faser AG, Germany), modified cellulosic (Hemophan; Akzo Faser AG), acrylonitrile-sodium methallyl copolymer-based membrane AN69S (Hospal, France), and SPAN, a new polyacrylonitrile-based copolymer (Akzo Nobel AG). The plasma FXIIA at the membranes surface was significantly different between the membranes, while the supernatant phase FXIIA exhibited no significant differences. In contrast, activation of purified FXII in a plasma-free system with respect to supernatant activity indicated significant differences between the materials. A similar finding for the membrane-bound factor XIIA was also observed when purified factor XII was used. The membrane-bound FXIIA values observed in the plasma system containing heparin were significantly greater than in citrated plasma. This demonstrated the strong influence of heparin and the interaction of other plasma components to the membrane surface on the activation of contact phase of coagulation. © 1996 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.