Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1990-1994  (1)
  • 1980-1984  (1)
  • 1970-1974  (2)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 72 (1992), S. 5687-5694 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The composition, distribution, and chemical bonding of tungsten-implanted glassy carbon have been studied for ion doses between 3.5×1014 and 1.5×1017 ions/cm2. The implantations were performed using a metal-vapor vacuum arc ion source which for an extraction potential of 20 kV yields a mean implant energy of 60 keV. The implanted layer was examined by Rutherford backscattering spectrometry and Auger profiling spectroscopy. In addition, volume effects were assessed by measuring the step height between implanted and unimplanted regions. It has been established that the implanted tungsten is bonded in a carbidic configuration. This is in agreement with thermodynamic data which favors carbide formation rather than separate phases of metallic tungsten and graphitic carbon. For the highest dose studied, 1.5×1017 ions/cm2, the tungsten distribution was found to be nearly constant near the surface followed by a decrease at larger depths. For ion doses up to 3.6×1016 ions/cm2, the maximum tungsten distribution was found to occur at a depth 300±100 A(ring) and the implanted and retained doses were found to be equal. For tungsten ion doses between 7.35×1014 and 1×1016 ions/cm2, the implanted region was found to be compacted by 300±100 A(ring). The latter is attributed to an irradiation-induced densification of glassy carbon from 1.5 to 2.1 g/cm3. This compaction effect is also found to occur upon C+ (30 keV) implantation for ion doses between 3×1016 and 1.3×1017 ions/cm2. In this case the implanted layer was compacted by 400±100 A(ring). For higher tungsten doses, a steep increase in compaction of the tungsten implanted layer was observed. This is attributed to chemical and sputtering effects.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 81 (1974), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Studies have been undertaken to determine whether the insulin response to intravenous glucose in a group of 20 to 24 week pregnant, potentially diabetic, women might be useful in the detection of those whose babies will be large. The investigation confirmed that glucose tolerance alone is not a good discriminant. Measurement of the first phase of insulin release, when corrected for the increased insulin release associated with maternal obesity, is a better discriminant. Other factors, including maternal obesity, contribute to the production of a large baby.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    BJOG 77 (1970), S. 0 
    ISSN: 1471-0528
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: A carefully defined group of postmature and mature fetuses have been compared by determining acid-base status, and blood gas, haematocrit values and glucose levels during labour and at delivery.The haematocrit value was the only parameter in which significant differences between the groups were found. These were not related to fetal oxygenation but to probable differences in hydration.No justification was found for the view that the postmature fetus is more liable to hypoxia before or during labour than its mature counterpart.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1434-0879
    Keywords: Neutron activation analysis ; stone formers ; bendrofluazide
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Whole body elemental compostion was measured by in vivo neutron activation analysis before and after treatment of urinary stoneformers with bendrofluazide for 6 months. There was no significant change in whole body calcium, sodium, nitrogen or body weight. There were significant reductions in whole body potassium (6%), chlorine (7.3%) and phosphorus (1.5%).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...