Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    College Park, Md. : American Institute of Physics (AIP)
    The Journal of Chemical Physics 95 (1991), S. 5701-5718 
    ISSN: 1089-7690
    Source: AIP Digital Archive
    Topics: Physics , Chemistry and Pharmacology
    Notes: Significant improvements have been obtained on measurements of the NO2 jet cooled excitation spectrum in the 16 300–18 502 cm−1 range, previously obtained by Smalley et al. [J. Chem. Phys. 63, 4977 (1975)], Persch et al. [Ber. Bunsenges. Phys. Chem. 92, 312 (1988)], and Hiraoka et al. [J. Mol. Spectrosc. 126, 427 (1987)]. The improvements concern first the rotational analysis, owing to a better resolution (150 MHz) and absolute precision (500 MHz), and second the completeness and purity of the resulting vibronic sequence, owing to a better sensitivity. As a result, 159 vibronic energy levels have been observed in the 16 500–18 500 cm−1 energy range, where 210±10 are expected. A detailed comparison with previous results is presented. The statistical analysis of the corresponding energy spacings shows that long range correlations up to 50 mean levels spacings are present, confirming the chaotic behavior of this set of vibronic levels. Furthermore, we analyze the observed rovibronic interactions (or rotational perturbations) that are responsible for the very irregular rotational behavior of the visible absorption spectrum of NO2 at room temperature.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of oral rehabilitation 21 (1994), S. 0 
    ISSN: 1365-2842
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Thirty-seven white Caucasian subjects with unsatisfactory dentures were tested for interocclusal thickness discrimination threshold. New dentures were prepared and the test was repeated on days 1, 4 and 90 (from delivery). Eight patients whose situation was still unsatisfactory were given osseointegrated implant anchored dentures and the test repeated at the same intervals. Results were analysed statistically. Improved denture fit was found to increase interocclusal sensitivity. Decreased sensitivity during follow-up might indicate the need to check denture fit.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1459
    Keywords: Myasthenia gravis ; Multicentre follow-up study
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A multicentre retrospective study was carried out on the characteristics and course of myasthenia gravis (MG) in Italy. Data from 1152 patients, fairly representative of the myasthenic population seeking medical advice, were analysed for diagnostic criteria, clinical aspects and therapeutic approaches. Mean follow-up was 4.9 years. The disease was correctly diagnosed within 2 years of the onset in 80% of cases. Onset of symptoms peaked in the second and third decade in females and fell between 20 and 59 years in males. At first observation 87% of the patients had generalized MG. Maximal worsening was observed within 3 years in 77% of patients. At the last follow-up, 35% of cases were symptom-free (pharmacological remission 24%, remission without treatment 11%). The more severe the disease at the first observation and at the maximal worsening of symptoms, the lower was the proportion of remissions. Steroids were given in 54% and immunosuppressants in 18%. Thymectomy was performed in 72%, mostly in women, younger than age 40, and with generalized MG. Thymectomy seemed to improve the course of the disease, mostly in patients operated on shortly after diagnosis and those with generalized mild-to-moderate disease and with a normally involuted thymus. MG was lethal in 4% of patients, principally men, older than 40, in grade 3 or worse at first observation, with a short history of disease, and with thymona.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    The international journal of cardiovascular imaging 9 (1993), S. 7-19 
    ISSN: 1573-0743
    Keywords: contrast agents ; echocardiography ; indicator-dilution principles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Contrast echocardiography has the potential for measuring cardiac output and regional blood flow. However, accurate quantitation is limited both by the use of non-standard contrast agents and by the electronic signal distortion inherent to the echocardiographic instruments. Thus, the aim of this study is to quantify flow by combining a stable contrast agent and a modified echo equipment, able to sample the radio frequency (RF) signal from a region of interest (ROI) in the echo image. The contrast agent SHU-454 (0.8 ml) was bolus injected into anin vitro calf vein, at 23 flow rates (ranging from 376 to 3620 ml/min) but constant volume and pressure. The ROI was placed in the centre of the vein, the RF signal was processed in real time and transferred to a personal computer to generate time-intensity curves. In the absence of recirculation, contrast washout slope and mean transit time (MTT) of curves (1.11–8.52 seconds) yielded excellent correlations with flow: r=0.93 and 0.95, respectively. To compare the accuracy of RF analysis with that of conventional image processing as to flow quantitation, conventional images were collected in the same flow model by two different scanners: a) the mechanical sector scanner used for RF analysis, and b) a conventional electronic sector scanner. These images were digitized off-line, mean videodensity inside an identical ROI was measured and time-intensity curves were built. MTT by RF was shorter than by videodensitometric analysis of the images generated by the same scanner (p〈0.001). In contrast, MTT by RF was longer than by the conventional scanner (p〈0.001). Significant differences in MTT were also found with changes in the gain setting controls of the conventional scanner. To study the stability of the contrast effect, 6 contrast injections (20 ml) were performed at a constant flow rate during recirculation: the spontaneous decay in RF signal intensity (t1/2=64±8 seconds) was too long to affect MTT significantly. In conclusion, the combination of a stable con trast agent and a modified echocardiographic instrument provides accurate quantitation of flow in anin vitro model; RF analysis is more accurate than conventional processing as to flow quantitation by contrast echocardiography.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    The international journal of cardiovascular imaging 9 (1993), S. 21-27 
    ISSN: 1573-0743
    Keywords: attenuation ; contrast agents ; echocardiography ; indicator-dilution principles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The combination of a standardized echographic contrast agent with the analysis of the ultrasonic radio frequency (RF) signal allowedin vitro flow quantitation in a circulation model. The purpose of this study was to investigate both the effects of biological tissues, intervening between probe and insonated structure, and the effects of the angle of incidence between flow and ultrasonic beam on RF flow quantitation. Thus, the contrast agent SHU 454 was intravenously injected (0.4 ml) as a bolus into a circulation model, at variable flow rates, while keeping the pressure and volume of the vessel constant. Injections were performed with saline interposed between probe and vessel and after the addition of the subcutaneous tissue of a pig; injections were also performed using the probe normal to the flow and with an angle of incidence of 45°. Echographic data were recorded by a mechanical sector scanner, capable of sampling the RF signal from a region of interest positioned in the center of the vein. Contrast echo time-intensity curves were generated. As expected, both peak intensity and the area under the curves decreased with intervening tissue (− 58 and − 70% of baseline values, respectively, p〈0.001). Surprisingly, mean transit time also decreased with intervening tissue (from 1.12±0.25 seconds with saline, to 0.92±0.13 seconds with tissue, p〈0.001), thus producing a systematic overestimation of flow (21% on the average). To compensate for signal attenuation, contrast injections were repeated in the presence of tissue after increasing the electronic signal amplification (10 dB), and transit time did not significantly differ from control. Moreover, mean transit time was slightly shorter with an angle of 45° (1.03 ° 0.19 seconds) than with an angle of 90° (1.12±0.25 seconds, p〈0.05). However, when the data collected with both angles of incidence were plotted together, the correlation with flow remained very close (r=0.94). In conclusion: intervening tissue influences flow quantitation by contrast echocardiography: these modifications can be compensated for by increasing the electronic signal amplification; the angle of incidence between flow and ultrasonic beam also influences flow quantitation: however, this influence is trivial, and can be neglected for practical purposes.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1590-3478
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Neurological sciences 11 (1990), S. 609-613 
    ISSN: 1590-3478
    Keywords: HIV infection ; muscle biopsy ; rod body myopathy ; light and electron microscopy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Sommario Gli AA riportano il caso di un soggetto di 35 anni omosessuale con una debolezza muscolare progressiva prossimale ai 4 arti ad impronta miopatica. L’EMG era di tipo miogeno; il CPK era lievemente aumentato; l’esame del liquor evidenziava un danno di barriera e positività degli anticorpi HIV. La biopsia muscolare evidenziava un quadro miopatico, con aspetti infiammatori, che comprendeva: marcata variabilità del diametro delle fibre, fibre necrotiche e fagocitosi, nuclei interni ed infiltrati linfo-istiocitari. Lo studio istochimico e istoenzimatico evidenziava compromissione di entrambi i tipi di fibre con modificazione delle attività ossidative nelle fibre in degenerazione. La microscopia elettronica mostrava un quadro di degenerazione miofibrillare con la presenza di caratteristici “rod bodies” nel 30% delle fibre. La stretta bra indicare l’esistenza di una specifica miopatia strutturale associata con l’AIDS.
    Notes: Abstract A 35 year old homosexual man showed clinical features of myopathy, with progressive muscular weakness of proximal muscles. EMG demonstrated a myopathic pattern; serum CPK was mildly elevated and CSF examination revealed antibodies to HIV and a blood-brain barrier damage. An open biopsy of the quadriceps femoris muscle showed myopathic changes with inflammatory features including a marked variation in fiber size, necrotic fibers and phagocytosis, a profusion of internal nuclei. Fiber type analysis with myosin ATPase reaction revealed that myopathic changes involved both fiber types. Changes in the oxidative enzyme activities were also observed in the degenerating muscle fibers. Electron microscopy showed patterns of myofibrillar degeneration and characteristic rod bodies in 30% of fibers. The close resemblance of the present morphological results with those recently observed in some HIV antibody positive men seems to indicate the existence of a specific structural myopathy associated with AIDS.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...