Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (3)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of clinical pharmacology 32 (1987), S. 289-295 
    ISSN: 1432-1041
    Keywords: theophylline ; pregnancy ; pharmacokinetics ; lactation ; methylxanthines ; metabolism
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Medicine
    Notes: Summary The effects of pregnancy on the disposition of theophylline were assessed in 10 patients throughout pregnancy and post-partum. The clearance relative to total theophylline concentrations was only slightly affected during the first two trimesters (2.61±0.63 l/h and 2.85±1.05 l/h), while a statistically significant reduction was evident late in pregnancy (2.05±0.49 l/h). Post-partum clearance values (2.16±2.81 l/h) suggest an ongoing suppression relative to pre-pregnancy levels. A similar pattern was evident with clearance values based on free theophylline plasma concentrations (p=0.12). Absolute volume of distribution increased in concert with gestation, suggesting that theophylline partitions into the enlarged tissue spaces. In addition, theophylline binding to plasma proteins decreased, albeit insignificantly, during the second (fraction bound=29%) and third (32%) trimesters compared to post-partum values (41%). Increases in half-life during the third trimester (13.00±2.31 h vs 9.53±3.53 h post-partum) were highly significant. This change reflects the net effect of reduced clearance and increased distribution. Breast feeding had no effect on the disposition of theophylline, although the transfer of this compound into breast milk was confirmed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 325 (1986), S. 263-266 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary The effect of the size of the added increment in standard additions determination on precision is evaluated by computer simulation. The precision obtained for different modes of calculating results is compared for double and single additions. The use of double additions up to the top of the linear range, combined with calculation of results by a weighted linear regression, is recommended.
    Notes: Zusammenfassung Der Effekt der Größe des zugesetzten Inkrements auf die Präzision bei Standardzugabe-Verfahren wird mit Hilfe einer Computersimulation ausgewertet. Die Präzision wird bei verschiedenen Berechnungsarten für einfache und doppelte Zugaben verglichen. Empfohlen wird die Verwendung doppelter Zugaben bis zur oberen Grenze des linearen Bereichs, kombiniert mit der Berechnung der Ergebnisse durch gewichtete lineare Regression.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 330 (1988), S. 103-106 
    ISSN: 1618-2650
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The performance of standard additions calibration is compared with direct calibration against standards. Computer simulation is used to provide information on the reduction of the useful analytical range associated with the use of standard additions. Provided that interference control measures necessary for direct calibration do not themselves degrade performance, the range over which acceptable precision is likely to be obtained will be reduced to between one third and one quarter ofthat attainable using direct calibration. Details of the usefulness of simple quality control measures which can be used in conjunction with standard additions are presented and their limitations are discussed. The conditions most favourable to the use of standard additions are outlined.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...