Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Acta neurochirurgica 54 (1980), S. 157-165 
    ISSN: 0942-0940
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A simple approach to stereotaxic radiography, including a new method for determination of target coordinates, is described. The proposed technique may be used in combination with conventional equipment for roentgen eximinations available in X-ray departments and operating rooms; the only additional outfit needed is a coordinate frame that can be attached to the patient's head. Determination of the coordinates is easily made graphically, or from a simple equation using a pocket calculator or a mini-computer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Annals of the New York Academy of Sciences 733 (1994), S. 0 
    ISSN: 1749-6632
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Natural Sciences in General
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1920
    Keywords: Computed tomography, head ; Stereotaxic techniques ; Head fixation system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary A head fixation system is described enabling exact transfer of positions between neuroradiological and therapeutic procedures. The key item of the system is a base plate that is rigidly attached to the patient's head, either by a plastic mould or screws onto the calvarium. The base plate may easily and accurately be attached to diagnostic or therapeutic units. Coordinates of target points in the various units are directly related through the exact application of the base plate. Procedures for the exact comparison of spatial information have been worked out. The system has been used for diagnostic procedures such as plain skull radiography, cerebral angiography, CT scanning, positron emission tomography, and gamma camera examinations, as well as for therapeutic procedures such as stereotaxic biopsy and radiation treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 418 (1991), S. 153-160 
    ISSN: 1432-2013
    Keywords: ATP ; Electrical stimulation ; Force ; Phosphate ; Phosphocreatine ; Relaxation ; Skeletal muscle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Force and relaxation were measured during electrical stimulation of the quadriceps muscle of 14 volunteers. Stimulation produced 51.2 s of intermittent ischaemic contractions either as 16 3.2-s tetani or as 64 0.8-s tetani. Changes during recovery were followed for 180 s. On 8 subjects muscle biopsies were taken during work and after the rest period for determination of ATP, phosphocreatine and intermediates in glucolysis. The stimulation using 0.8-s contractions gave more pronounced fatigue and slowing of relaxation. There was a good correlation between force and relaxation during work but this relation changed during recovery, indicating that no general relation exists between these two contraction characteristics. In the 0.8-s stimulation more ATP was utilized and there were more profound changes in metabolite levels. We found a correlation between estimated [H2PO 4 − ] and relaxation covering both work and recovery and hypothesize that inorganic phosphate and its removal by phosphocreatine resynthesis during recovery might be important. Since stimulation patterns differ in force and relaxation even after the recovery period we suggest that additional factors, such as pH, are of importance in this work model.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Pflügers Archiv 417 (1990), S. 136-141 
    ISSN: 1432-2013
    Keywords: Electrical stimulation ; Fatigue ; Force ; Frequency ; Skeletal muscle
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Percutaneous electrical stimulation was used to study the force response of the quadriceps muscle. The normal frequency dependence of force was investigated in muscles at rest and after fatiguing contractions. A comparison between force response during fatigue induced by electrical stimulation at different frequencies and by voluntary work suggested equal changes in contractility, irrespective of the fatigue-inducing procedure. In fresh muscle we found a linear relation between stimulation period (10–100 ms) and force. At fatigue the relation changes with maximal deviation from linearity at a 50-ms period (20 Hz). There is a rapid recovery of high frequency force whereas the low frequency response remains low even after 30 min rest. At very low frequencies there is initially unexpectedly high force in fatigued muscle. This could be a result of increased fusion of twitches with initially prolonged relaxation time. To study the twitch summation we compared experimental results in a wide frequency range with computer-simulated twitch summations and present the frequency dependence of summation processes in human quadriceps muscle.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 19 (1980), S. 123-129 
    ISSN: 1432-1920
    Keywords: Computed tomography ; Acoustic neuroma ; Internal auditory meatus ; Attenuation profiles
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Attenuation profiles across the petrous bone covering the whole internal auditory meatus (IAM) were constructed from the printouts obtained by computed tomography (CT) with narrow collimation performed on 12 patients with 13 acoustic neuromas. In healthy patients the attenuation profiles of right and left petrous bone were very similar in shape. The attenuation values of the individual pixels in the pixel columns of the printout located at the site of the porus and the IAM reflected the demineralization of the petrous bone and the widening of the porus and the IAM caused by the acoustic neuroma. A widening deep in the meatus was demonstrated in a patient with an intracanalicular tumor, and therefore it seems possible to make this diagnosis by CT scanning combined with the construction of attenuation profiles across the petrous bone. In the presence of unilateral acoustic neuroma there was a significant and characteristic difference in shape between the attenuation profiles of the two sides with generally lower attenuation values on the tumor side together with signs of widening of the porus and the IAM. In cases of bilateral acoustic neuroma comparison of the attenuation profiles can be made with mean attenuation curves obtained from scanning normal petrous bones. The prevailing physical limitations for demonstrating a narrow bony canal like the IAM with CT was experimentally analyzed using bone-simulating plastic material.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Neuroradiology 19 (1980), S. 7-12 
    ISSN: 1432-1920
    Keywords: Computed tomography ; Stereotactic techniques
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Two head-fixation systems, one using Thermoplast and the other Lightcast were tested as to reproducibility by comparing stereotactic coordinates before and after CT scan and after removal and reapplication of the helmets. Helmets constructed of Lightcast were more consistently stable than those constructed of Thermoplast probably due in part to the dental fixation used with the former. With Lightcast the change in position of coordinates was consistently less than 3 mm, i.e. 2 pixels, which is within the tolerance of the system as a whole.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    ISSN: 1434-601X
    Keywords: 21.10.−K ; 21.60.−n ; 25.70.−z ; 27.70.+q
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The strongly shape driving πh9/2[541]l/2− configuration with α=+1/2 exhibits some anomalous, and so far unexplained, features concerning the crossing frequency, ħωc, the aligned angular momentum, ix, and interaction strength, at the alignment of the first pair of i13/2 quasineutrons in several odd-Z rare earth-nuclei. The h9/2[541]1/2− and h11/2[523]7/2− bands have been studied in the stably deformed rare-earth nucleus163Tm to investigate these features. A difference in band crossing frequency of ∼ 80 keV between the two bands is found. Rotational bands built on these two configurations have been found to cross in the spin range I=25/2–29/2 ħ. Theγ-decay pattern between the two bands is established in the crossing region and analysed in terms of a moderate shape difference between them. A theoretical estimate of the size of the interaction strength between the two bands is presented and compared to the experimental value. The observed band structure in163Tm is very similar to that of167Lu which has 2 protons and 2 neutrons in addition. This observation is discussed in relation to the similarity of the yrast bands of the two even-even “core” nuclei162Er and166Yb, for which theγ-transition energies are identical within ∼0.2 keV below the vi13/2 crossing.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...