Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1985-1989  (2)
  • 1980-1984  (3)
  • 1935-1939  (4)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 58 (1936), S. 854-854 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 60 (1989), S. 3482-3484 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: It is shown that care must be exercised in using digital equipment when making Hall measurements in a van der Pauw setup employing the ASTM standard method. This arises because of quantization error when working near the sensitivity limit of the equipment. For materials with small Hall mobilities (〈100 cm2/V s) this can lead to an incorrect specification of the carrier type and inconsistent mobility behavior. A simple averaging and sampling procedure is suggested to suppress this type of behavior and is found to be sufficient to obtain reliable and repeatable Hall voltages and coefficients.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial and engineering chemistry 8 (1936), S. 108-108 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Industrial and engineering chemistry 10 (1938), S. 647-648 
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of the American Water Resources Association 16 (1980), S. 0 
    ISSN: 1752-1688
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Geography
    Notes: : Several problems that make it difficult to deal with water pollution from cropland are identified. The most immediate need is for a rational framework for determining where conservation programs can make an impact on eutrophication problems in reservoirs draining rural watersheds. This includes estimating the level of control that would be required for each local farm situation and the economic impacts for the planning area. A modeling approach is suggested for a planning area in Southeastern Pennsylvania.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 58 (1936), S. 2444-2445 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical & experimental allergy 13 (1983), S. 0 
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Serum venom-specific IgE and IgG were monitored in twenty-three patients receiving venom immunotherapy for more than 3 years. Two response patterns of IgE antibody were found. Following initiation of therapy, seven patients had a rise in serum venom-specific IgE, peaking at one year, then decreasing. Sixteen patients had a persistent fall in IgE antibody titres following initiation of therapy. At the end of 3 years, levels of serum venom-specific IgE in both groups were comparable. The presence of atopy may have influenced the rising IgE antibody response.Serum venom-specific IgG either rose or remained elevated if the pretreatment titres were high. After several years of therapy, there was generally a decrease in serum venom-specific IgG.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical & experimental allergy 13 (1983), S. 0 
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The clinical and immunologic response to a modified rapid (r) regimen of venom immunotherapy was evaluated and compared to a traditional (t) therapeutic regimen. Nineteen patients in the r group received a starting dose of 0.01 μg and reached a maintenance dose of 50 μg in 7 weeks. Twelve patients in the t group received an average of twenty-one injections on a weekly basis, reaching the same maintenance dose. The age and sex distribution and pre-treatment venom-specific IgE titres (RAST) of both groups were comparable.There were thirteen local reactions to venom therapy in both groups and no systemic reactions. Following therapy, most patients developed a rising titre of serum venom-specific IgG (V-IgG). Serum venom-specific IgE (V-IgE) changes were similar in the two groups; over half of the patients had a falling titre when on maintenance dose.Twelve patients were re-stung after reaching maintenance dose. Only one developed a mild systemic reaction, an individual who failed lo show a V-IgG response with rapid therapy. Five of nine patients did not have an anamnestic V-IgE response.This rapid method of venom immunotherapy appears to be safe, clinically effective, and comparable to traditional dosing without additional adverse reaction.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Clinical & experimental allergy 15 (1985), S. 0 
    ISSN: 1365-2222
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Following insect sting anaphylaxis, twenty-five patients of over 500 evaluated, did not have detectable serum venom-specific IgE. Twenty-two were evaluated within 1 year of the reaction, fifteen within 6 months. Anaphylaxis occurred in six patients after their first sting exposure. The clinical features of the sting reaction were typical of the reaction occurring in insect-allergic patients with serum venom-specific IgE. Eleven of the twenty-five patients had negative venom skin tests. These observations suggest that a non-IgE mechanism may be responsible for a minority of insect sting reactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...