Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1975-1979  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 18 (1979), S. 151-167 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Summary A thorough analysis of the viscoelastic behaviour of 193 synovial fluid samples of knee joints concerning different joint diseases (inflammatory and non-inflammatory) gives no essential diagnostic help in case of clinical problems. Investigations were done particularly on flow curves including the Newtonian viscosityη 0 and normal forces, and with the help of a standardization-method we got master curves. In three cases we also got dynamic properties i.e. the elastic modulusG′ and the loss modulusG″. By comparison of the pathological synovial fluid samples with normal, post-mortem pooled synovial fluid one gets an idea of the degree of disturbance on viscoelasticity. It was found that the reduced concentration and the lower molecular weight of the hyaluronic acid are responsible for the pathological variation of the concentration independent bending timet k as well as the shape of the master curves. Tests on concentrated pathological synovial fluids indicate the beginning formation of micro-gels. In cases of absence of normal forces even after concentration no normal forces could be detected. Therefore the possibility of disturbed intermolecular interactions in pathological synovial fluids will be discussed, too.
    Notes: Zusammenfassung Die eingehende Analyse des viskoelastischen Verhaltens von 193 Kniegelenkspunktaten verschiedenster entzündlicher und nichtentzündlicher Gelenkerkrankungen ließ keine wesentlichen diagnostischen Hilfen für klinische Problemfälle erkennen. Untersucht wurden im einzelnen Fließkurven einschließlich der Anfangsviskositätη 0 und durch eine Normierungsmethode ermittelte master-curves, sowie Normalspannungen und in 3 Fällen gleichzeitig auch der SpeichermodulG′ und der VerlustmodulG″ mit Hilfe von dynamischen Messungen. Durch Vergleich der pathologischen Gelenkpunktate mit normaler, post mortal gewonnener gepoolter Synovia ließ sich ein Eindruck vom Grad der gestörten Viskoelastizität gewinnen. Dabei lassen die erniedrigten Hyaluronsäure-Konzentrationen, die Veränderungen der konzentrationsunabhängigen Knickzeitt k〉 und die master-curve erkennen, daß hierfür sowohl eine verringerte Konzentration als auch ein geringeres Molekulargewicht der Hyaluronsäure verantwortlich ist. Konzentrierungsversuche pathologischer Synovia ergaben den Hinweis auf die Entstehung von Mikrogelen und ließen in Fällen zuvor fehlender Normalspannungen auch nach der Eindickung keine Normalspannungen erkennen. Es wird deshalb auch die Möglichkeit gestörter intermolekularer Interaktionen in der pathologischen Synovia diskutiert.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Rheologica acta 16 (1977), S. 378-384 
    ISSN: 1435-1528
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Physics
    Description / Table of Contents: Summary In 107 pathological synovial fluid samples of knee joints (47 non-inflammatory, 60 inflammatory) the Weissenberg-Rheogoniometer is used for measurements of viscosity, normal force and a shear modulus obtained by prestationary measurements to calculate the number of molecular entanglements. Viscosity and elasticity of the inflammatory synovial fluids are clearly different from the non-inflammatory group, but the high scattering of the values shows that various pathological conditions lead to the same rheological properties of the synovial fluid. Therefore the rheological results have little diagnostic signification. Variation of the hyaluronic acid concentrations are responsible only in part for the pathological synovial fluid rheology. A normalization method for the synovial fluid viscosity suggests differences in the polymerisation of the hyaluronic acid in inflammatory and non-inflammatory synovial fluids.
    Notes: Zusammenfassung Mit Hilfe des Weissenberg-Rheogoniometers wurden an 107 pathologischen Kniegelenkspunktaten (47 nicht entzündliche, 60 entzündliche) das viskose Fließverhalten, Normalkräfte und anhand von Anlaufmessungen ein Schermodul zur Berechnung der Anzahl molekularer Verhängungen bestimmt. Viskoses und elastisches Verhalten der entzündlichen Gelenkergüsse unterscheiden sich zwar deutlich von dem der nichtentzündlichen Ergüsse, die hohe Streuung der Werte weist jedoch darauf hin, daß verschiedene pathogenetische Vorgänge zu den gleichen rheologischen Eigenschaften der Synovia führen können. Daher ist der differentialdiagnostische Aussagewert der rheologischen Untersuchungsergebnisse gering. Hyaluronsäure-Konzentrationsänderungen sind nur zum Teil für die pathologische Rheologie der Synovia verantwortlich. Die Anwendung einer Normierungsmethode auf die Viskosität der Synovia läßt Unterschiede im Polymerisationsgrad der Hyaluronsäure in entzündlichen und nicht entzündlichen Ergüssen erkennen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...