Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 22 (1971), S. 144-147 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 22 (1971), S. 351-355 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 23 (1971), S. 115-117 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 23 (1971), S. 143-154 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Depending upon particle size, shape and consistency typical differences are caused, both in the percentages of the boundary impulses, which are known to be overvalued, and also in the mean overvaluation of particules, that pass near the border of the measuring-aperture. a) Particles, that are large in relation to the measuring-aperture and which pass near the border of the aperture, move, asTom previously mentioned [7], only with a part of their volume through the denser boundary of the electrical field. This causes by means of a smaller overvaluation a smaller curve skewness to the right. b) Erythrocytes, fixated with a biconcave shape, are more over-estimated—because of this shape—near the border of the measuring-aperture, in comparison with round fixated erythrocytes. The curve-distorsion to the right changes accordingly. Biconcave-fixated erythrocytes are able to turn near the border of the outlet and so produce three-peaked impulses. c) Native, biconcave erythrocytes show—because of their exceptional elasticity—in the dense electrical field near the border of the measuring-outlet, the highest false volue. They produce in the border electrical field multiple impulses with two or more peaks, which can be explained due to the deformability of these cells. d) When during a reading, lysolecithin is used to produce sphering of native, biconcave erythrocytes, the impulse picture is changed and with it the curve-distorsion to the right, in a typical way. The results show good agreement with these of round fixated erythrocytes. Therefor the influence of the turning or deforming particles in the measuring-aperture can be shown.
    Notes: Zusammenfassung In Abhängigkeit von Partikelgröße,-form und-konsistenz ergeben sich typische Unterschiede sowohl in den prozentualen Anteilen der als überbewertet erkannten Randimpulse als auch in der mittleren Überbewertung von Partikeln, die die Meßöffnung im Randbereich passieren: a) Partikel, die im Verhältnis zur Meßöffnung groß sind und diese im Randbereich passieren, treten, wie schonThom erwähnt [8], nur mit einem Teil ihres Volumens durch das dichte elektrische Feld an den Kanten und bewirken durch die geringere Überbewertung auch eine geringere Rechtsschiefe. b) Bikonkav-fixierte Erythrozyten werden auf Grund ihrer Form im Randbereich der Meßöffnung mehr überbewertet als rund-fixierte Erythrozyten. Die Rechtsschiefe ändert sich entsprechend. Bikonkav-fixierte Erythrozyten können sich im Randbereich der Meßöffnung drehen und erzeugen dreigipflige Impulse. c) Native bikonkave Erythrozyten zeigen auf Grund ihrer außerordentlichen Elastizität im dichten elektrischen Randfeld der Meßöffnung die höchste Fehlerbewertung. Sie erzeugen im elektrischen Randfeld eine Vielzahl von zwei-und mehrgipfligen Impulsen. Dies kann durch die leichte Deformierbarkeit dieser Zellen erklärt werden. d) Werden native bikonkave Erythrozyten während einer Messung durch Lysolecithin sphärisch transformiert, ändert sich das Impulsbild und damit auch die Rechtsschiefe in typischer Weise. Die Ergebnisse zeigen dann gute Übereinstimmung mit denen von rund-fixierten Erythrozyten. Es kann damit der Einfluß sich in der Meßöffnung drehender oder verformender Teilchen gezeigt werden.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary The intramolecular disulfide bonds of bovine fibrinogen were cleaved by sulphitolysis in 8 M urea in order to dissociate the protein into its single peptide chains. The reaction mixture obtained, unlike fibrinogen, was unable to promote the sedimentation rate of an erythrocyte suspension. Besides this, it inhibited the effect of fibrinogen on the sedimentation rate. It was assumed that the fibrinogen sub-units may combine monovalently with the erythrocyte surface. By this means binding sites may be blocked but agglomeration will not take place. When separated chromatographically all three subunits of fibrinogen showed this inhibition effect. The β(B)-chains were most active, the α(A)-and γ-chains were of equal effect.
    Notes: Zusammenfassung Die intramolekularen Disulfidbindungen von Rinderfibrinogen wurden durch Sulfitolyse in 8 M-Harnstoff gespalten und dadurch das Protein in seine Peptidketten zerlegt. Das erhaltene Reaktionsgemisch beschleunigt zum Unterschied von Fibrinogen die Senkung einer Erythrozytensuspension nicht. Es hemmt aber die beschleunigende Wirkung von Fibrinogen auf die Senkung. Dies wird damit erklärt, daß die Fibrinogenuntereinheiten monovalent mit den Erythrozytenoberflächen reagieren, wobei sie Haftstellen besetzen, ohne jedoch eine Agglomeration der Erythrozyten herbeizuführen. Jede der drei Peptidketten des Fibrinogens besitzt diese Hemmwirkung, am stärksten die β(B)-Kette, etwa gleich stark die α(A)-und die γ-Kette.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 23 (1971), S. 174-175 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 27 (1973), S. 197-199 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 29 (1974), S. 224-226 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Annals of hematology 21 (1970), S. 389-394 
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1432-0584
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary Bovine fibrinogen was processed according toMosesson andSherry yielding fractions of various solubility. The more soluble fractions I-6 and I-9 appear to be less effective than ordinary fibrinogen (fraction I-4) in promoting the sedimentation rate of erythrocytes. In addition, their thrombin clotting time is considerably prolonged and somewhat higher concentrations are needed to produce sharp precipitation lines when diffusing against rabbit anti-fibrinogen. The cold insoluble fraction I-1 as well as fraction I-2, which represent fibrinogen of less purity, react in the investigations as similar as the pure fraction I-4. Fraction I-8 from which only minute amounts are obtained, doesn't show any effect on the erythrocyte sedimentation rate and is a poor antigen in the diffusion test. The pure fibrinogen possesses the greatest biological activity. There is at least a qualitative relationship between the change in the chemical structure of the different fractions and the decrease of their biological activity.
    Notes: Zusammenfassung Rinderfibrinogen wurde nach den Angaben vonMosesson undSherry in Fraktionen aufgetrennt, die sich in ihrer Löslichkeit unterscheiden. Die leichter löslichen Fraktionen I-6 und I-9 zeigen gegenüber normalem Fibrinogen (Frakt. I-4) eine geringere Wirkung auf die Blutkörperchensenkungsgeschwindigkeit. Sie weisen außerdem eine deutlich verlängerte Thrombinzeit auf und geben im Diffusionstest gegen Kaninchen-Antifibrinogen erst bei höheren Konzentrationen optimale Präzipitationslinien. Die kalt-unlösliche Frakt. I-1 sowie Frakt. I-2, die etwas weniger reines Fibrinogen darstellt, verhalten sich in den genannten Reaktionen ähnlich wie die reine Frakt. I-4. Die nur in geringer Menge anfallende Frakt. I-8 ist ohne Wirkung auf die Blutkörperchensenkungsgeschwindigkeit und zeigt im Diffusionstest wenig Antigenwirksamkeit. Das intakte Fibrinogen besitzt also in allen drei Tests die größte biologische Wirksamkeit. Es besteht mindestens eine qualitative Beziehung zwischen der Veränderung der chemischen Struktur der einzelnen Fibrinogenfraktionen und der Abnahme ihrer biologischen Aktivität.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...