Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 11 (1970), S. 263-281 
    ISSN: 1432-1106
    Keywords: Repetitive discharge ; PT cell ; Fast-slow cell groups ; Kinetictonic patterns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Responses to current steps were recorded from pyramidal tract (PT) cells of the cat by means of intracellular microelectrodes. PT cells with resting potentials from -60 to -80 mV set up a well sustained repetitive discharge during stimulation. When comparing fast and slow PT cells, quantitative differences were found between them in the pattern of repetitive firing. Thus, (1) the rheobase is lower in slow PT cells (mean and S.D.; 0.53±0.63 nA) than in fast cells (1.57±1.11 nA). (2) Following stimulation with a current step twice rheobase the latency and the successive interspike intervals are shorter in fast PT cells than in slow cells. (3) The interspike interval distribution shows a greater irregularity in fast PT cells than in slow cells. At firing rates around 30 impulses/sec the coefficient of variation has a mean value of 0.243 for fast PT cells and 0.085 for slow cells. (4) Fast PT cells show a greater decrease of firing rate during the initial 300 msec of current stimulation (adaptation) than do slow cells. The mean value of this initial decrease is 1.85 times the later steady firing rate in fast PT cells and 0.56 times in slow cells. (5) The slope constant of the firing rate-current relationship is larger in fast PT cells, being five times or more than in slow cells. These characteristics of firing pattern are termed “kinetic” and “tonic” for fast and slow PT cells respectively, and their functional meanings are discussed in comparison with other neural organs.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1106
    Keywords: Sodium ions ; Electrogenic Na pump ; Post-tetanic hyperpolarization ; PT cell
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Sodium ions were injected into cat pyramidal tract (PT) cells electrophoretically through an intracellular NaCl or Na glutamate-filled microelectrode. Following an injection there were decreases in the maximum rates of rise and fall of the spike potential and there was displacement of the inhibitory postsynaptic potential in a depolarizing direction. These changes recovered with an exponential time course, indicating concomitant changes in the internal sodium, potassium and chloride concentrations under the operation of the sodium pump in extruding excess sodium. From the exponential recovery curve, the rate constant of active sodium extrusion was estimated as about 60 hr−1 in fast PT cells and about 90 hr−1 in slow PT cells. It was suggested that the sodium pump was at least partly electrogenic, since the resting membrane was hyperpolarized by the sodium injection to the degree which depended on the amount of sodium-injecting current. Further support for this possibility was obtained by the experiment of high-frequency activation of PT cells, in which the sodium entry through the active membrane developed a slow post-tetanic hyperpolarization.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1420-9071
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Zusammenfassung Der Effekt von sechsβ-adrenergischen Blockierungsmitteln auf Akonitin-Arrhythmia bzw. Ouabain-Arrhythmia wurde mittels i.v. Verabreichung vergleichend untersucht. Reihenfolge der Wirksamkeit auf Akonitin-Arrhythmia: Propranolol〉MJ 1999〉LB 46〉H 56/28, ICI 50172 und DCI, und dieselbe auf Ouabain-Arrhythmia: Propranolol, LB 46 und H 56/28 gleichwertig, MJ 1999 und ICI 50172 wirkungslos.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...