Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Admittance plethysmography  (3)
  • Analytical Chemistry and Spectroscopy  (3)
  • far-infrared  (3)
Materialart
Erscheinungszeitraum
Schlagwörter
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 549-559 
    ISSN: 1572-9559
    Schlagwort(e): interferometer ; polarimeter ; water-vapor laser ; far-infrared ; plasma diagnostics ; compact toroid
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract A high-power CW 27.972 μm water-vapor laser has been developed for interferometric and polarimetric measurements of plasmas. The maximum output power and the power density in the cavity of the laser with 2.0 cm bore and 220 cm length reach 85 mW and 109 μW/cm3, respectively. An interferometer using this laser is constructed and its performance is examined as a study on polarimetric method of magnetic field measurement. Preliminary interferometric experiments are also carried out on a compact toroidal plasma with field-reversal configuration.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 2 (1981), S. 1199-1208 
    ISSN: 1572-9559
    Schlagwort(e): water vapor laser ; plasma diagnostics ; interferometer ; waveguide laser ; far-infrared
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract A high-power CW 27.972 μm water vapor laser has been constructed in order to use as a light source of an interferometer for plasma diagnostics. The laser consists of 220 cm length and 2.0 cm small bore Pyrex glass discharge tube, semi-confocal resonator and Michelson coupler. From the measurement of cavity detuning curves, it is found that two waveguide modes, EH11 and EH21 oscillate. The increase of the output power is found to become more than seven times larger by adding He(50%)−H2(50%) mixed gas. Under the optimum condition, the maximum output power of 65 mW or the output power per unit cavity volume of 83 μW/cm3 is obtained.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Springer
    International journal of infrared and millimeter waves 5 (1984), S. 1039-1052 
    ISSN: 1572-9559
    Schlagwort(e): H2O laser ; Faraday rotation ; polarimetry ; far-infrared ; plasma diagnostics ; compact toroid
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Physik
    Notizen: Abstract A fast response frequency-modulated interferometric polarimeter was designed and constructed with a single 28 μm H2O laser for high density plasma diagnostics. This newly developed modulation system employs an electro-magnetically driven movable mirror to achieve the modulation frequency beyound 1 MHz for about 100 μs duration. The movable mirror performance is studied experimentally in detail. The determination of the Faraday rotation angle is based on the zero-crossing method for the observed beat signals produced by two kinds of rotating plane-polarized waves. The feasibility of the polarimeter constructed was verified in experiments of a field-reversed thetapinch plasma.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 19 (1981), S. 426-432 
    ISSN: 1741-0444
    Schlagwort(e): Admittance plethysmography ; Respiration rate ; Stroke volume ; Three-channel telemetry ; Total transthoracic admittance
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract A three-channel frequency-modulation telemetry system for the noninvasive measurement of cardiac output, rate of respiration, e.c.g. and basal transthoracic admittance of the unconstrained human subject is described. Tetrapolar admittance plethysmography has been employed to obtain the transthoracic admittance and its variations corresponding to the cardiac cycle and respiratory changes. Pulse duration modulation has been used in the transmitter system. The nonlinearity of the system is less than ±2·0%. The telemetry transmitter has a range of about 100 m, it weights approximately 200 g and is contained in a box measuring 150×100×50 mm. The batteries used provide a continuous life of 20 h. The system has been used to obtain data from normal subjects in different postures with breath hold and during normal respiration.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 26 (1988), S. 641-646 
    ISSN: 1741-0444
    Schlagwort(e): Admittance plethysmography ; Arterial compliance ; Human limb ; Noninvasive measurement ; Volume elastic modulus ; Volume oscillometric method
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Arterial elasticity expressed by such indices as volume elastic modulus Ev and compliance Ca were noninvasively measured in various human limb segments; the upper arms, forearms, fingers, thighs, calves and toes. These indices are defined, respectively, as $$E_v = \Delta P/(\Delta V/\bar V_a )$$ and Ca=ΔV/ΔP, where ΔP is pulse pressure, $$\bar V_a $$ mean arterial volume and ΔV its pulsatile variation. ΔP was calculated from systolic Pas and mean Pam arterial pressures determined by volume oscillometric sphygmomanometry using the following equation: $$\Delta P = 3(P_{as} - P_{am} )/2\bar V_a $$ and the ΔV were detected by electrical admittance plethysmography at various transmural pressure Pt levels controlled by a compression cuff. The values obtained in these limb segments were compared with each other at Pt levels 0,30 and 60 mm Hg and the differences between them were discussed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 23 (1985), S. 43-47 
    ISSN: 1741-0444
    Schlagwort(e): Admittance plethysmography ; Arterial compliance ; Arterial volume ; Vascular unloading technique ; Volume elastic modulus
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Static and dynamic (beat-to-beat) arterial viscoelastic properties were measured noninvasively in human fingers and forearms. The volume change and pressure change were detected simultaneously by admittance plethysmography and by sphygmomanometry using the vascular unloading technique in the index and middle finger, or vice versa. These simultaneous measurements were also made on the forearms of one side and the fingers of the other side. The arterial viscoelastic properties in these segments could be successfully determined at different transmural pressure levels from 0 mm Hg to around the mean arterial pressure.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 5 (1991), S. 437-440 
    ISSN: 0951-4198
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: The mass spectrum of mercury/cesium complex clusters (Hg)nCs+ is observed up to m/z=118 000 (n = 590). Singly charged clusters are produced by Cs+ ion bombardment. The presence of an alkali metal in the ionization process yields cluster ions of the form (Hg)nX+. The clusters are analysed using the grand-scale mass spectrometer, GEMMY, at Osaka University. The mass resolution of the instrument is high enough to resolve each cluster up to m/z=70 000. From the pattern of cluster distribution, the structrues of the large clusters can be studied. The number of Hg groups in metastable decay increases with the cluster size n. The ion intensities of the mercury/cesium clusters are much stronger than that from CsI (used for mass calibration). The mass spectrum of the clusters can therefore easily be utilized for direct mass calibration up to m/z=70 000.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    ISSN: 0951-4198
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 16-18 
    ISSN: 0951-4198
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: Two types of magnesium oxide clusters, (MgO)n+ and (MgO)nMg+ have been obtained by the bombardment of magnesium with a mixture of xenon and oxygen ions. Enhanced ion intensity in the cluster mass spectra was observed at certain n values. The correlation between the geometrical structures of the clusters and their abundances is discussed.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...