Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-2277
    Keywords: Conversion from steroids to azathioprine, in kidney transplantation ; Azathioprine conversion after steroids, in kidney transplantation ; Acute rejection after conversion, in kidney transplantation ; Cyclosporin and conversion, in kidney transplantation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In renal graft recipients primarily treated with cyclosporin and low-dose methylprednisolone, withdrawal of the long-term steroid medication increases the likelihood of developing rejection episodes. In order to determine the predictive value of clinical parameters and routine prewithdrawal graft biopsies for the risk of rejection, the authors studied 141 kidney recipients from whom steroids were with-drawn 7–9 months after transplantation in a clinically stable situation. Both the quality of the HLA-match and the results of prospective graft biopsies were found to correlate significantly to the occurrence of acute rejection. In order to investigate the influence of additional azathioprine medication on the incidence of acute rejections in recipients not receiving steroids, immunosuppression was continued with cyclosporin monotherapy in 88 patients and with cyclosporin plus azathioprine in 53 patients. The risk of developing rejection episodes was significantly reduced from 48% after 1 year on monotherapy to 28% after the addition of azathioprine medication.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-0630
    Keywords: 72.20.Jv ; 29.40.Pe ; 85.60.Dw
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract The photoelectric response of p-n Si photodiodes under pulsed laser illumination (half width 10 ns) at 532 nm was studied as a function of dose which was varied over 6 orders of magnitude. The photocurrent transients are dominated by a plateau-like feature due to the build up of space charge at the intensities used. Increasing bias voltage increases the height of the plateau and decreases its length. In the low-dose range the length of the transient increases linearly with dose and the collected charge (integrated current) reaches a constant value. At high doses (above 10−5 J/pulse · cm2 or 2.7×1013 quanta/pulse · cm2) considerable charge loss (decrease in quantum yields) is accompanied by a less than proportional increase of the transient lifetime. From model calculations the dose and voltage dependence of the quantum yield of charge collection is shown to be the result of competition between current flow and first and higher order recombination. The model calculations are consistent with experimental results. Rate constants have been obtained by fitting.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...