Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0630
    Keywords: 42.10 ; 81.60 ; 82.50
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract Experiments that demonstrate quantitatively the importance of laser absorption dynamics for ultraviolet laser ablation of organic materials are presented. Laser pulse transmission measurements have been performed on 0.1 μm spin-coated polyimide films at three ultraviolet wavelengths (193 nm, 248 nm, and 355 nm) over the fluence range 10−3 −10 J/cm2. Target transmission is observed to increase with increasing fluence by a factor of ∼5 at 193 nm, and a factor of ∼10 at 248 nm. In contrast, transmission decreases by approximately one half during 355 nm target irradiation. These results are analyzed theoretically with a two-level model of chromophore absorption. This theory is also applied to reported pulsed UV-laser polyimide ablation data. It is shown that an accurate description of the fluence-dependent film absorption leads to a prediction of the etch depth versus pulse fluence relationship in good agreement with experimental data.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European radiology 9 (1999), S. 1324-1326 
    ISSN: 1432-1084
    Keywords: Key words: Intralobar lung sequestration ; Bronchiectases ; Right coronary artery
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Pulmonary sequestration is a rare anomaly. An accurate pre-operative evaluation of its vascular supply is essential for the surgeon's operative approach. We describe here an intrapulmonary sequestration with vascular arterial supply via the left circumflex and the right coronary artery. This case demonstrates that if aortography is unrevealing, then a coronary source should be considered in the preoperative search for the arterial supply to a pulmonary sequestration. Moreover, pulmonary sequestration should be listed in the differential diagnosis of aberrant coronary arteries.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...