Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Development genes and evolution 183 (1977), S. 41-59 
    ISSN: 1432-041X
    Keywords: Imaginal discs ; Pattern formation ; Cell death ; Duplication
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Notes: Summary We describe the range of phenotypes caused by cell death when larvae of the heat-sensitive cell-lethal mutant,l(1)ts726 ofDrosophila, are subjected to heat treatment at different stages of development. When the treatment extends into the pupal period, certain bristles fail to develop but the disc derivatives are otherwise normal. Earlier treatments cause the replacement of sets of leg and eye-antennal markers by mirror image duplications of neighbouring sets. The results are compared in detail with those expected under a gradient model proposed earlier to account for the phenotype. It is found that although the results for the second leg are in excellent agreement with the predictions of the model, a more elaborate hypothesis is necessary to account for the eye-antennal disc data. Abnormal head patterns fall into several distinct categories, any one of which could be explained by postulating the existence of a gradient, if other categories did not also occur. The markers affected in each case belong to overlapping sets, and each category of pattern can be induced by heat treatments administered throughout the temperature-sensitive period. The statistical distribution of the data is such that only one category of pattern would be detected in a small scale experiment. The possible implications relative to pattern formation in normal development are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Journal of Polymer Science: Polymer Chemistry Edition 17 (1979), S. 2783-2790 
    ISSN: 0360-6376
    Keywords: Physics ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The vinyl acetate centered triad fractions of some free radically prepared ethylene-vinyl acetate and styrene-vinyl acetate copolymers have been determined from the patterns of vinyl acetate methine carbon peaks in their 13C nuclear magnetic resonance (NMR) spectra. The positions and shapes of the carbonyl bands in the infrared (IR) absorption spectra of the copolymers recorded in chloroform are shown to depend on the compositions of the copolymers and on the proportions of the various vinyl acetate centered triads. Infrared absorption measurements may thus be used in part to characterize the monomer sequence distributions of these copolymers.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Biopolymers 13 (1974), S. 2103-2115 
    ISSN: 0006-3525
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A theoretical study of effects of excluded volume intermolecular interactions on the sharpness of helix-coil transitions in solutions of polyamino acids or simple proteins indicates that the transition width may vary appreciably as a function of polymer concentration. The analysis is based on a second virial approximation for the excess free energy of mixing of a solution of polymers of varying degrees of helicity. The virial coefficients involved are roughly estimated on the basis of gross polymer geometry. For large N (degree of polymerization) the transition is found, typically to sharpen with increasing concentration, becoming second order and then first order at sufficiently high concentrations. The critical polymer concentration is found to be roughly of the order N-1.2 d0-1 for an “all or none” model and of order σ1/2 N-0.2 d0-1 for a model with continuously variable degree of helicity (d0 is the volume of a single helical molecule and σ1/2 the normalized statistical weight of a helix-coil interface). In the second case for N ∼ 103 and σ ∼ 10-2-10-4, the predicted critical concentration is in the range 10-1-10-3 g/cm.3 Comparison is made with experiments on solutions of poly(γ-benzyl-L glutamate).
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...