Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 4 (1990), S. 151-155 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Sequence information is obtained by in-source fragmentation of electrospray-generated peptide ions. The complete sequences of leucine enkephalin, angiotensin I, and renin substrate are determined from their fragment ions and consume only low picomole amounts of material. The method involves collision-induced fragmentation of singly and multiply charged molecular ions in the electrospray ion source and does not involve tandem mass spectrometric instrumentation. The charge on the fragment ions is determined by the spacing of the isotope peaks.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 12 (1985), S. 586-587 
    ISSN: 1052-9306
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Positive and negative ion fast atom bombardment (FAB) mass spectra of the molecular ion region of calcitonin using several solution matrices produce an isotopic distribution which is indicative of a mixture of reduced and oxidized disulfide bonds. The insensitivity of the distribution to the choice of matrix and positive/negative ion mode suggest that the spectra reflect the natural abundance of reduced calcitonin in the sample, rather than an artifact of the fast atom bombardment technique.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 731-735 
    ISSN: 0935-6304
    Keywords: GC-ECD ; Dual-column ; Organochlorine pesticides ; Chlorobiphenyl congeners ; Fish ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The simultaneous analysis of α-HCH, β-HCH, γ-HCH, HCB, p,p′-DDD, p,p′-DDT, p,p′-DDE, o,p′-DDT, mirex, dieldrin and 62 chlorobiphenyl congeners on two parallel capillary GC columns of different polarity is described for nine Mediterranean fish species. Ten commercially available columns with stationary phases completely characterized in respect of their PCB elution patterns were considered for dual-column GC-ECD analysis. The combination of a 60 m × 0.25 mm i.d. column coated with a 0.25 μm film of 50% diphenyl dimethylsiloxane and a series combination of a 25 m × 0.25 mm i.d. column coated with a 0.25 μm film of 5% diphenyl dimethylsiloxane with a 25 m × 0.22 mm i.d. column coated with a 0.10 μm film of 1, 10-dicarba-closo-dodecarborane dimethylpolysiloxane furnished the highest number of separated chlorobiphenyl congeners (104). The dual-column GC system performed with high stability and reproducibility over a broad concentration range (1-3000 ng/g lipid) of the organochlorine compounds in the investigated fish.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...