  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 42 (1996), S. 405-408 
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Meropenem in rat plasma ; Column-switching
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The purpose of this study was to develop a columnswitching HPLC method for the determination of meropenem in plasma. This method showed excellent precision and accuracy with good sensitivity and speed. The total analysis time per sample was less than 20 min and the mean coefficients of variation for intra- and inter-assay were less than 4.0%. The method has been successfully applied to plasma samples from rats receiving an intraperitoneal injection of meropenem.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Column-switching ; Parathion, and metabolites in serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new high-performance liquid chromatographic method with column-switching has been developed for the simultaneous determination of parathion and its metabolites such asp-nitrophenol and paraoxon in serum. Serum samples were injected onto a precolumn packed with LiChroprep RP-8 after simple dilution with 20% phosphoric acid. Polar plasma components were washed with 0.02 M phosphate buffer (pH 3.0). After valve switching, the concentrated compounds were eluted in back-flush mode and separated on a Ultracarb ODS 30 column with a gradient of acetonitrile −0.01 M phosphate buffer (pH 3.0) as mobile phase. The method showed excellent precision, accuracy and speed with detection limit of 0.1 μg mL−1. Total analysis time per sample was 〈40 min and coefficients of variation for intra-and inter-assay were 〈4.5%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column Liquid chromatography ; Column-switching ; Losartan and EXP3174 in plasma
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new liquid chromatographic method with columnswitching has been developed for the simultaneous determination of losartan and its active metabolite, EXP3174 in rat plasma. The plasma samaple was injected onto a precolumn of Lichroprep RP-8 after dilution with 5% acetonitrile in 50 mM phosphoric acid. Polar plasma components were eluted using this diluent. After valve switching, the concentrated drugs were eluted in the back-flush mode and separated by an Inertsil ODS-2 column with acetonitrile-acetate buffer. The method showed excellent precision, accuracy and speed with detection limit 20 ng mL−1. Total analysis time per sample was less than 40 min and the coefficients of variation for intra and inter-assay were 4.8%. This method has been successfully applied after oral administration of losartan to rat plasma samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microbore columns ; Column-switching ; Myristicin ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A microbore high-performance liquid chromatographic method with column-switching was developed for the analysis of myristicin from rat serum without prepurification. Deproteinization, fractionation, concentration and separation of analyte were carried out by appropriate switching of columns and using solvent mixtures. The method showed excellent precision, accuracy and speed with a detection limit of 10 ng mL−1 from 25 μL of serum. The total analysis time per sample was 25 min and the coefficients of variation for intra- and inter-assay were less than 1.8%.