Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Chemical polishing  (1)
  • Cobalt  (1)
  • Detector systems for microdiffraction  (1)
  • Electron Ronchigrams  (1)
  • 1
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Microscopy Research and Technique 20 (1992), S. 426-438 
    ISSN: 1059-910X
    Schlagwort(e): Reflection high energy electron diffraction ; Surface topography ; Chemical polishing ; Life and Medical Sciences ; Cell & Developmental Biology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Allgemeine Naturwissenschaft
    Notizen: We have employed several different methods to prepare (100) and (111) surfaces of MgO crystals. (100) surfaces prepared by simple cleaving give good reflection high energy electron diffraction (RHEED) patterns and surfaces with a high density of coarse steps. Chemical polishing of this surface results in a roughening of the topography whilst annealing in oxygen considerably smoothens the surfaces although they appear to be contaminated. Under certain conditions we find that the MgO crystals will cleave along the (111) plane. Both cleaved and mechanically polished (111) surfaces are atomically flat and reconstructed after oxygen annealing.
    Zusätzliches Material: 12 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Microscopy Research and Technique 25 (1993), S. 341-345 
    ISSN: 1059-910X
    Schlagwort(e): Magnetic domains ; Thin films ; Iron ; Cobalt ; Scanning transmission electron microscopy ; Annular detector ; Life and Medical Sciences ; Cell & Developmental Biology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Allgemeine Naturwissenschaft
    Notizen: A simplified mode of differential phase contrast Lorentz microscopy for the study of magnetic domain structures in thin films is proposed and demonstrated. This mode employs a single annular detector in a scanning transmission electron microscope rather than the specialized split detectors that have been previously used. The resulting signal is sufficiently linear with magnetic field strength to allow quantitative data to be obtained on the domain configurations and the natures of the domain walls. © 1993 Wiley-Liss, Inc.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Microscopy Research and Technique 30 (1995), S. 181-192 
    ISSN: 1059-910X
    Schlagwort(e): Electron Ronchigrams ; Numerical reconstruction ; Lens aberrations ; Life and Medical Sciences ; Cell & Developmental Biology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Allgemeine Naturwissenschaft
    Notizen: In a dedicated STEM instrument equipped with a field emission gun, shadow images are easily obtained and have many uses. They are very sensitive to misalignment of the instrument and astigmatism, and therefore can be used for rapid and accurate alignment of the microscope. For crystalline materials, the shadow image contains both the bright-field and dark-field images. It is a summation of the transmitted and diffracted beams, and is basically a kind of Gabor's in-line hologram. Under small or medium defocus, shadow images of a thin, well-orientated crystalline specimen take the characteristic form of Ronchigrams, which offer a unique means to calibrate the microscope operation parameters, such as the spherical aberration coefficient Cs and defocus settings of the objective lens, with high accuracy. With the calibrated values of Cs and δ, a transfer function of the objective lens may be generated. In the stage of numerical reconstruction, by adapting this transfer function to the experimentally recorded hologram the lens aberration introduced in forming the hologram may be corrected and an improved resolution may be achieved for electron microscope images. © 1995 Wiley-Liss, Inc.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    Journal of Electron Microscopy Technique 11 (1989), S. 143-154 
    ISSN: 0741-0581
    Schlagwort(e): Detector systems for microdiffraction ; STEM imaging ; Coherent diffraction effects ; Image reconstruction from diffraction patterns ; EELS ; SEM ; Life and Medical Sciences ; Cell & Developmental Biology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Allgemeine Naturwissenschaft
    Notizen: A two-dimensional detector system, designed for the observation and recording of microdiffraction patterns formed in an HB 5 scanning transmission electron microscope (STEM) is described and discussed. Possibilities are described and demonstrated for the simultaneous or successive recording of microdiffraction patterns from regions of diameter 3 å or more, bright- or dark-field STEM images, EELS spectra, secondary electron images, and in-line holograms. Applications of the system have been made to studies of catalyst particles, reflection-mode imaging of bulk surfaces, and image reconstruction from microdiffraction patterns obtained from each point of a STEM image.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...